background image

*2

*5

*3

*3

*2

*3

*2

*9

*9

*9

*1

*1

*1

*11

*13

*12

*7

*8

*5

*10

*10

*10

*4

*6

*4

*4

*6

Note

1.How to set the time

1) Pull out the crown to the second click position.
2) Turn the crown to set hour and minute hands.

(Check that AM / PM is set correctly.)

3) Push the crown back into the normal position.

[ Note ]

2.How to set the date

1) Pull out the crown to the first click position.
2) Turn the crown clockwise for date setting.

*Do not set the date between 9:00 P.M. and 3:00 A.M. as this will cause a malfunction.

3) Push the crown back into the normal position.

3.How to reset (after battery change)

It is possible to reset by the following two methods.

1) Set the crown to the normal position.

Method 1

2) Touch the AC terminal of circuit block and the switch spring with conductive tweezers 

 to reset the circuit.

3) The small second hand will move at two-second interval for 10 seconds.

1) Pull out the crown to the second click position.

Method 2

2) Press the button B for two seconds and release the button.
3) Push the crown back to the normal position.
4) The small second hand will move at two-second interval for 10 seconds.

* If the crown is operated within this 10 seconds, the two-second interval movement will not activate.

[ Note ]

It is not necessary to set the chronograph hands after the battery is exchanged. 
If the chronograph hands position are incorrect, following below procedure all the chronograph hands
will be reset to "0" position.

*1:

*6:

*5:

*4:

*3:

*2: Minute hand

Chronograph second hand
Small second hand

*9:

13

SII Products

DISPLAY AND CROWN / BUTTON OPERATION

Hour hand

Chronograph minute hand
 (60 minute)

Chronograph minute hand
 (20 minute)

Crown at second position
 (Time setting)

*12:

Button B  (RESET)

Button A  (START / STOP)

Version-01

VK Series

OPERATION

<< VK63 >>

<< VK67 >>

<< VK83 >>

*11:

*10:

*13:

If the crown is pulled to the second position while the chronograph is started, the chronograph hands
will continue to move. This is not a malfunction.

Crown at first position
 (Date setting)

Crown at normal position

*7:

Chronograph hour hand
 (12 hour)

24 hour hand

*8:

Button B

(RESET)

Button A

(START)

Button A

(STOP)

Содержание Cal.VK Series

Страница 1: ...SII Products ANALOGUE QUARTZ TECHNICAL GUIDE PARTS CATALOGUE Cal VK Series Issued on 05 Jan 2011...

Страница 2: ...m O O O 60 second per round O O O 60 second per round Casing diameter Movement Movement size VK63 SII Products PARTS CATALOGUE TECHNICAL GUIDE Cal No Item Cal VK Series VK67 VK83 Total height Version...

Страница 3: ...ndicator maintaining plate Date dial 0810 019 Date jumper 0806 002 Date corrector wheel 2 1 7 2 3 Cross section Refer to page 7 for each parts code Refer to page 7 for each parts code Refer to page 7...

Страница 4: ...0837 005 Switch lever holder 4450 017 Switch lever A 4450 018 Switch lever B 0962 891 0962 013 SII Products 3 Version 01 VK Series PARTS CATALOGUE 8 9 10 11 12 14 Date corrector setting transmission...

Страница 5: ...0894 002 Train wheel stop lever 0888 017 0587 004 Hammer operating lever A 23 Hammer operation lever B Refer to page 7 for each parts code 20 22 25 Second counting wheel 19 21 Refer to page 7 for eac...

Страница 6: ...e for chronograph bridge screw 33 Minute counter intermediate wheel and pinion C 34 Minute counter intermediate wheel and pinion B 0886 007 Cal VK63 VK83 0886 006 Cal VK63 VK83 33 Hour counter interme...

Страница 7: ...42 Coil block B 4146 063 Step rotor 0221 087 4239 064 Stator B 0383 891 0701 015 0384 024 Yoke 0240 018 Second wheel 0282 452 Clutch wheel 0962 012 0351 177 Winding stem 6 PARTS CATALOGUE Version 01 V...

Страница 8: ...hour hand wheel and pinion O Intermediate date wheel and pinion 7 O O O 0802 039 0685 002 0157 012 Small hour hand wheel Date indicator driving wheel 23 O O Positioning arbor O 0902 011 Minute counti...

Страница 9: ...l and pinion 37 36 34 34 36 38 Counter intermediate wheel and pinion Nil 8 SII Products 36 G 33 Nil E F Hour counter intermediate wheel and pinion A 33 34 36 Counter intermediate wheel and pinion 35 A...

Страница 10: ...raph bridge Note Switch spring Oiling spot and spring setting position Chronograph coupling lever Hammer operation lever B Setting position Switch spring TECHNICAL GUIDE Version 01 VK Series 16 1 Oili...

Страница 11: ...osition Switch spring Switch spring Switch lever B Switch lever A Hammer operation lever A Chronograph coupling lever Switch lever B is set between the switch spring and hammer operation lever A Switc...

Страница 12: ...ch spring s battery clamp catch the main plate Switch spring Battery clamp 1 When Removing Main plate 2 When Installing 7 Remarks on installing the battery 1 After the battery is replaced with a new o...

Страница 13: ...hour hand pull out the crown to the second click position and rotate it clockwise until changed to the next date then install the 24 hour hand 9 How to check correct hands attachment The hand s top su...

Страница 14: ...utton B for two seconds and release the button 3 Push the crown back to the normal position 4 The small second hand will move at two second interval for 10 seconds If the crown is operated within this...

Страница 15: ...63 and VK67 Cal VK83 The chronograph can measure up to 20 minutes The chronograph stops after a measurement for 20 minutes Restart in the following procedure Cal VK63 67 83 in common During the chrono...