Time Guard SLFM360 Скачать руководство пользователя страница 3

2

Wiring cover

Factory fitted
bridge wire
REMOVED

L1

L N E

Switched
Load
OUT

Factory fitted
bridge wire

Levering area

Time On 

setting

Lux -

Dusk/Dawn

setting

Mains 
Supply 
IN

In the above illustration:
- 4 core cable may be used
- there is no external junction box
- A bridge is provided, prewired to bridge
across live supply from AC mains to the
output load via the contacts

In the above illustration:
- the L1 L2 terminals are used to control a
DC load or if the load uses a different phase
or voltage supply from the AC mains in.
- factory fitted bridge must be removed to
isolate L1 & L2 terminals from AC mains in.

Cable clamps x2

Locators

L

ocating

springs
pulled
back

L

ocating

springs 
fitted 
position

Sensor

Levering area

D

E

F

G

L1

L N E

Switched
Load
OUT

Mains 
Supply 
IN

SLFM360_Instruct_art_2.2.qxd  3/5/06  10:05 am  Page 2

Содержание SLFM360

Страница 1: ...I N S TA L L AT I O N O P E R AT I N G I N S T R U C T I O N S 360 FLUSH MOUNT CEILING PIR LIGHT CONTROLLER Cat No SLFM360...

Страница 2: ...or over lighting an area can be limited by carefully considering the location and position of your unit before installation The light spread on all halogen floodlights can be reduced by angling the fl...

Страница 3: ...ewired to bridge across live supply from AC mains to the output load via the contacts In the above illustration the L1 L2 terminals are used to control a DC load or if the load uses a different phase...

Страница 4: ...le for indoor use only Connected load must not exceed maximum 2000W filament incandescent or 500W fluorescent low energy lighting Do not attempt to install if you are suffering from nausea or dizzy sp...

Страница 5: ...ation under extreme conditions During extreme weather conditions the motion sensor may exhibit unusual behaviour This does not indicate a fault with the sensor Once normal weather conditions return th...

Страница 6: ...F Remove the factory fitted bridge wire Connect the 3 core mains supply cable to the terminal block on the unit as follows NEUTRAL Blue N EARTH Green Yellow LIVE Brown L Connect the load in series wit...

Страница 7: ...e centre of the sensor location with a 2 5m ceiling As you cross a detection zone the lamp will illuminate Now stand still until the lamp extinguishes this should take approx 5 seconds Start moving ag...

Страница 8: ...e DUSK control knob fully anti clockwise The unit will now start operating at dusk If you require the light to activate earlier wait until the ambient light level reaches the level of darkness at whic...

Страница 9: ...t back into position under spring pressure Manual Override Mode The light can be switched on for longer time periods by use of the Manual Override Mode This can be activated at night by using the isol...

Страница 10: ...has failed replace Ensure that the lamp is seated correctly in the lampholder Please note that the unit will not detect through glass e g in a glazed porch The level of ambient light in the area may b...

Страница 11: ...t low energy lighting Not suitable for discharge lighting 75W Fan 5 seconds 18 minutes Day night or night only operation Internal use only 73 23 EEC and 89 336 EEC Technical specifications Detection R...

Страница 12: ...In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase please return it to your supplier in the first year with proof of...

Отзывы: