Timberline Tool TC2-SR Скачать руководство пользователя страница 3

GENERAL SAFETY RULES

For all Tools

READ and UNDERSTAND all instructions.  Failure to follow all instructions listed 
below may result in serious personal injury and/or damage to the tool.

The following ASTM standards provide guidance and requirements for squeeze-off 
tools, operating procedures, and qualifi cation procedures.
• 

ASTM F1041, “Standard Guide for Squeeze-off of Polyolefi n Gas Pressure 
Pipe and Tubing”

• 

ASTM F1563, “Standard Specifi cation for Tools to Squeeze-Off Polyethylene 
(PE) Gas Pipe or Tubing”

• 

ASTM F1734, “Standard Practice for Qualifi cation of a Combination of Squeeze 
Tool, Pipe, and Squeeze-Off Procedures to Avoid Long-Term Damage in Poly-
ethylene (PE) Gas Pipe”

* The SDR is the ratio of pipe diameter to wall thickness. SDR can be be expressed 
as SDR = D/s where D = pipe outside diameter and s = pipe wall thickness.

TIMBERLINE TC2-SR

3

INTRODUCTION

Timberline squeeze-off tools are designed to temporarily stop the pressurized fl ow of 
liquid or gas in polyethylene (PE) pipe.

Squeeze-off is a technique used to control the fl ow of gas or liquid in polyethylene 
pipe by compressing the pipe between parallel bars until the inside surfaces make 
contact.  The fl exibility and toughness of most polyethylene pipes allow the pipe to 
recover from a properly made squeeze-off without a measurable loss in service life.  
Squeeze-off is useful for making installation tie-ins and emergency repairs.

Timberline squeeze-off tools are made from high strength aluminum for superior 
durability and will not bend or break under normal use. However, care must be taken 
to ensure that the pipe is free of foreign material and the pipe setting on the rotating 
sleeve matches the diameter and wall thickness / SDR of the pipe to be squeezed. *  

Please read the following suggested procedure for squeezing off polyethylene plastic 
pipe using Timberline Squeeze-off Tools.

Содержание TC2-SR

Страница 1: ...Instruction Manual Model TC2 SR TopSide Clamp top side clamp SAVE these instructions for future reference For your personal safety READ and UNDERSTAND instructions before using tools...

Страница 2: ...inks A5 Rotating Jaw Sleeve A6 Safety Locking Bar A7 Slow Release Nut A8 Slow Release Threaded Rod 2 SPECIFICATIONS Table 1 Squeeze off Tool for 1 2 CTS to 2 CTS 12 7mm CTS 51 8mm CTS 1 2 IPS 2 IPS 12...

Страница 3: ...BERLINE TC2 SR 3 INTRODUCTION Timberline squeeze off tools are designed to temporarily stop the pressurized flow of liquid or gas in polyethylene PE pipe Squeeze off is a technique used to control the...

Страница 4: ...the hazards involved Workplace Safety Prior to using any squeeze off tool consult ASTM Standards F1041 02 F1563 01 and F1734 03 Always follow applicable company and OSHA safety procedures Observe pip...

Страница 5: ...ght affect the operation of the tool Accidents may be caused by improperly maintained tools Always use the Timberline TC2SR with the grounding rod inserted in the ground when working with natural gas...

Страница 6: ...round the tool with the Grounding Rod Fig 1 2 Turn the Slow Release Nut counter clockwise until it is close to the end of the threaded rod so the jaw can completely open Fig 2 3 Rotate the Jaw Sleeve...

Страница 7: ...ng Bar by moving the Quick Release Pin from the UNLOCK position to the LOCK position Fig 7 Make sure the tool is perpendicular to the pipe during squeeze off 8 Close the handles until the tool goes ov...

Страница 8: ...r move the Quick Release Pin from the hole marked LOCK to the hole marked UNLOCK and remove any lock out tag out devices Open the handles slowly until you feel the tool go back over center 12 To contr...

Страница 9: ...tool and or performing a test squeeze on a pipe pressurized with air If you have questions please feel free to contact our customer service representatives at 1 800 735 6845 or by email at service tim...

Страница 10: ...others Repairs are required because of normal wear and tear The tool has been abused misused or improperly maintained Alterations have been made to the tool IN NO EVENT SHALL TIMBERLINE TOOL BE LIABL...

Страница 11: ...This page intentionally left blank TIMBERLINE TC2 SR 11...

Страница 12: ...406 755 4258 406 257 2711 www timberlinetool com 90 Conestoga Ct Kalispell MT 59901 USA...

Отзывы: