7. MAINTENANCE

During use of the water heater, scale may appear in nozzle openings of the 
shower or kitchen spout. This reduces efficiency of heating, deteriorated 
water spraying, and increases water pressure in the heating vessel.
For prevention of such phenomena, it is necessary to periodically clean the 
nozzle  using  household  chemical  agents  and  soft  brushes.  Do  not  use 
abrasive cleaning substances and inappropriate chemical agents.

a) Outer care:
- Switch off the appliance and allow it to fully cool down.
- Clean the outer surface of the appliance enclosure using a slightly moist-

ened soft cloth and then wipe it dry. Do not use abrasive cleaning sub-
stances.

b) Filter cleaning:
If water flow rate from the heater decreases, it is necessary to clean the 
coarse filter installed at the cold water inlet to the water heater. Use the 
following procedure:
- Switch off the appliance and allow it to fully cool down.
- Shut off cold water feeding.
- Unscrew the cold water feed hose from the water heater, remove the 

coarse strainer and flush it under a jet of flowing water.

- Restore the inlet connections in the reverse sequence.

8. TROUBLESHOOTING

Table 3

9. DISPOSAL

Upon  expiration  of  service  life,  the  water  heater  shall  be  disposed.  For 
more details regarding disposal of the water heater, please contact a repre-
sentative of the local authorities.

Water is too hot

Water is too cold

Increase water flow rate
Clean spout openings

Check electric power supply
Decrease water flow rate
Reset the thermal switch

10

www.timberk.com 

    

electric i

nstant water heater

Содержание WHEL-3OC

Страница 1: ...OC Electrical instant water heater Instruction manual Outlook of devices aslo colour scores can be revised without any special advance notices WHEL 3 OSC WHEL 6 OSC WHEL 7 OSC WHEL 3 OS WHEL 6 OS WHEL 7 OS Primalux series Серия Primalux ...

Страница 2: ...cord and do not con nectthewaterheaterviaelectricextensioncables 5 Neverusethewaterheater ifitisfaulty 6 Immediatelydisconnectthewaterheaterfromtheelectric mainsincase ofstrangesounds odor orsmokefromit 7 Always disconnect the water heater from the electric mains during storms CONTENTS 1 Importantinformation 2 Precautions 3 Specifications 4 Packagecontents 5 Waterheaterinstallation 6 Waterheaterco...

Страница 3: ...ter and excludetheircontactwithit 10 To avoid hazard of electric shock the damaged power cord shall be replacedonlybyqualifiedspecialists 11 To avoid hazard of electric shock do not place the power cord near heatingappliancesandflammableorcombustiblematerials 12 Do not use the water heater for purposes not specified in this instruc tionmanual 13 Do not use the water heater in explosive or corrosiv...

Страница 4: ...kW Mpa Mpa L min mm2 mm H W H kg WHEL 3 crane 220 50 16 3 5 0 0 03 0 6 1 9 I IPX4 3 1 5 159x272x112 1 35 WHEL 3 OS shower 220 50 16 3 5 0 0 03 0 6 1 9 I IPX4 3 1 5 159x272x112 1 35 WHEL 3 OSC crane and shower 220 50 16 3 5 0 0 03 0 6 1 9 I IPX4 3 1 5 159x272x112 1 35 Table1 4 www timberk com electric instant water heater IMPORTANT Technical characteristics of the water heater you purchased as of t...

Страница 5: ...4 159x272x112 1 19 Table1c PARAMETER Version Rated voltage Rated current Rated power consumption Rated pressure Operating pressure Flow rate at t 20 C Electric protection class Moisture protection class Wire section of electric connection cabel Dimensions Net weight Unit of measure V Hz A kW Mpa Mpa L min mm mm H W H kg PARAMETER Version Rated voltage Rated current Rated power consumption Rated pr...

Страница 6: ...s screw dowel pin Water heater assembly Instruction manual Warranty card pcs 1 1 1 1 1 1 3 2 1 3 1 1 1 WHEL 3 WHEL 6 OC WHEL 7 OC WHEL 3 S WHEL 6 OS WHEL 7 OS WHEL 3 S WHEL 6 OSC WHEL 7 OC Table2 Electicity connection cabel for WHEL 3 series 5 WATER HEATER INSTALLATION Location 1 The water heater can be installed in any place provided that temperature in the room is not below 0 C 2 Possible instal...

Страница 7: ... with screws from the set of installation fixtures includedbythemanufacturertothepackage NOTE Installation of the water heater in the operation place and arrange ment of a power supply line shall be performed by a specialized organization representatives of the manufacturer s service department or specialists having permits for installation of electric equipmentwithobservationsofsafetyrequirements...

Страница 8: ...ection of the electric circuit 16 25 30Adependingonseriesofthewaterheater Leadtheelectriccableintothewaterheater Fix bare ends of the electric cable in a connection box hardly tightening them with screws and in strict correspondence with the box marking re fertoFig 3 Check connection tightness of all internal electric contacts including re movable contact groups and bolt contact connections on hea...

Страница 9: ...flow rate of water usingtheflowcontrolvalveatthewaterinlettothewaterheater To switch off the appliance place the switch to the OFF position and closethecoldwaterfeedvalve ATTENTION Donotswitchonthewaterheater ifyoususpectfreezingofwaterin it Thewaterheaterisequippedwiththefollowinginstrumentation Theheatingelementisactivatedonlyatoptimumwaterpressureinrange from 0 03 to 0 6 MPa Its lower range val...

Страница 10: ...eaning If water flow rate from the heater decreases it is necessary to clean the coarse filter installed at the cold water inlet to the water heater Use the followingprocedure Switchofftheapplianceandallowittofullycooldown Shutoffcoldwaterfeeding Unscrew the cold water feed hose from the water heater remove the coarsestrainerandflushitunderajetofflowingwater Restoretheinletconnectionsinthereverses...

Страница 11: ...11 2 1 2 3 5 3 220 50 4 1 2 3 4 5 6 7 8 9 10 Timberk 0 TIMBERK 1 11 11 13 15 15 18 19 19 19 20 www timberk com ...

Страница 12: ...17 18 19 20 21 22 23 IN OUT 24 25 26 27 28 29 35 30 31 5 6 7 8 9 10 11 12 13 14 15 16 12 www timberk com ...

Страница 13: ...EL 3 220 50 16 3 5 0 0 03 0 6 1 9 I IPX4 1 5 159x272x112 1 35 WHEL 3 OS 220 50 16 3 5 0 0 03 0 6 1 9 I IPX4 1 5 159x272x112 1 35 WHEL 3 OSC 220 50 16 3 5 0 0 03 0 6 1 9 I IPX4 1 5 159x272x112 1 35 1 www timberk com 1 1 1 ...

Страница 14: ...X4 3 2 5 159x272x112 1 19 WHEL 6 OSC 220 50 25 5 5 0 0 03 0 6 4 0 I IPX4 3 2 5 159x272x112 1 19 1 t 20 E WHEL 7 220 50 30 6 5 0 0 03 0 6 4 5 I IPX4 3 4 159x272x112 1 19 WHEL 7 OS 220 50 30 6 5 0 0 03 0 6 4 5 I IPX4 3 4 159x272x112 1 19 WHEL 7 OSC 220 50 30 6 5 0 0 03 0 6 4 5 I IPX4 3 4 159x272x112 1 19 1 www timberk com ...

Страница 15: ...4 2 1 1 1 1 1 1 3 2 1 3 1 1 1 WHEL 3 WHEL 6 OC WHEL 7 OC WHEL 3 S WHEL 6 OS WHEL 7 OS WHEL 3 S WHEL 6 OSC WHEL 7 OC 2 5 1 0 2 1 15 www timberk com 1 5 WHEL 3 ...

Страница 16: ...16 0 6 2 2 0 03 0 6 4 1 www timberk com ...

Страница 17: ... 220 15 3 1 5 16 WHEL 3 3 2 5 25 WHEL 6 3 4 30 WHEL 7 WHEL 3 16 25 30 WHEL 3 220 16 25 30 220 2 2 17 www timberk com ...

Страница 18: ...18 220 В к контуру заземления 6 WHEL 3 4 WHEL 6 WHEL 7 5 LOW MEDIUM HIGH Рис 4 Рис 5 4 5 10 20 3 20 ON Low WHEL 6 7 OFF ON High WHEL 6 7 OFF 0 03 0 6 0 03 3 www timberk com WHEL 3 3 5 16 18 ...

Страница 19: ... Timberk www timberk com 7 8 3 9 5 19 www timberk com ...

Страница 20: ...3 115162 28 4 74956044266 74956044266 P 60335 2 35 2000 P51318 14 1 2006 4 P51318 14 2 2006p 5 7 P51317 3 3 2008 P51317 3 2 2006p 6 7 RUC IL AB71 B 00051 09 02 2012 08 02 2015 20 www timberk com 10 88000 972 8 637 88 311 111024 5 2 1 74996537356 7 495 6275285 ...

Страница 21: ...RU Timberk Timberk KZ AK BY OS TJ UA KG CIS c 10 21 www timberk com ...

Страница 22: ... Timberk Timberk www btpart ru www timberk com Timberk 22 www timberk com ...

Страница 23: ...23 www timberk com www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com ...

Страница 24: ...ÀÂ71 www timberk com ...

Отзывы: