www.timberk.com • electric humidifier
7
In case of emergencies use troubleshooting methods, listed in Table 2.
If it is impossible to remedy problems by the listed methods, contact the
manufacturer’s service center.
9. TROUBLESHOOTING
Table 2
Problem
Possible cause
Remedy
Poor atomizing (insufficient capacity)
The unit is operating in the minimized
mode (low atomizing frequency)
There is no problem. If you need
to switch to the intensive mode of
operation, turn the regulator handle
all the way to the right.
The atomizer is clogged
Clean the atomizer.
Temperature of water in the tank
is too low
Set maximum capacity. The
humidifier’s capacity will go up
after a while.
No atomizing
The power cord is poorly connected
to the outlet
Connect the power cord into the
outlet carefully
There is white deposit on objects
around the humidifier (salts,
separating out from water)
1. Lime deposits have formed on the
membrane
2. There is a lot of salts in the water
used (calcium and magnesium)
1. Clean the humidifier’s membrane
with a special brush
2. Use filtered water
Steam has an unpleasant odor
Stale water is used
Clean the unit according to the
cleaning and servicing instructions
and fill the tank with fresh water
Remains of stale water or waste have
accumulated in the unit’s case or
the atomizer
Condensate is formed on the
upper part of the humidifier and
on surrounding objects, when it is
operating.
1. High humidification intensity is set.
2. High room humidity and
temperature.
Lower the humidification intensity by
turning the on/off and steam outflow
intensity regulator counterclockwise.
Water appears next to the humidifier,
when it is operating.
1. High humidification intensity is set.
2. Lime deposits have formed on the
membrane and in grooves for water
(in the unit’s base).
1. Lower the humidification
intensity by turning the on/off and
steam outflow intensity regulator
counterclockwise.
2. Clean the unit according to the
cleaning and servicing instructions.
10. TRANSPORTATION AND STORAGE
1. When transporting, any possible impacts and movements of the
package inside a vehicle must be avoided.
2. Handling symbols on the unit’s package must be strictly observed when
transporting and storing it.
3.
Temperature
requirements*
Humidity
requirements*
Transportation and
storage
-30°C to +50°C
15% to 85%
(no condensate)
We are researching new technologies and constantly improving the quality
of our products. Specifications, design and scope of delivery may be
changed without any prior notice.
* Products must be stored in dry, ventilated storages at the temperature
not lower than -30°C.
The humidifier’s life is 2 years. At the end of life, the humidifier must be
disposed in accordance with regulations, rules and method, effective in
the disposal area.
11. DISPOSAL
Содержание THU MINI 02
Страница 19: ......
Страница 20: ...www timberk com ...