5. Water heater with the mounted valve must be connected to the water
main – install a shut-off valve at the water inlet point. You need to connect
a drain pipe to the opening of the pressure relief of safety valve. Next you
should put a drain pipe to the sewer.
6. Connect the desired number of consumption points to the outlet nozzle,
marked red.
7. Check leak integrity of joints: open the shut-off cock and one of the cock
assemblies. After the tank is filled with water, as evidenced by issue of water
from the cock assembly, shut the cock assembly and check the leak integrity
of all joints.
NOTE:
Do not mount additional accessories, such as a shut-
off valve, between the relief valve and the inlet nozzle.
Connection to electric main
IMPORTANT!
Prior to connecting the tank water heater, make sure
that the water heater is properly grounded. Proper
grounding is important to minimize electric shocks
and risk of fire. The power cord is equipped with a plug
with a grounding pin. The appliance must be used
with a properly grounded power outlet. If the outlet,
you are intending to use, is not properly grounded or
grounded by a time-delay fuse or a circuit breaker,
contact a qualified electrician to install a proper outlet.
IMPORTANT!
If water in the installation location contains a large
amount of calcium, manganese or iron salts, then
IT IS NECESSARY to mount a respective filter in
the delivery system to reduce the amount of scale
generated in the tank and on the heating element.
bolts, enclosed with the water heater, insert bolts, turn the hook upwards,
securely tighten nuts and then hang the electric water heater on these hooks
(see Fig. 6).
3. Fix a power outlet to the wall. Requirements to the outlet are as follows:
220V/10A, single-phase, three-wired. It is recommended to place the outlet
on the right side above the water heater.
4. If a bathroom is too small, the water heater can be installed elsewhere,
unexposed to direct sunlight and unavailable for moisture. However, to
reduce heat losses in pipelines, the location, where a water heater is to be
installed, must be as close to the place, where hot water is used, as possible.
Connection to water main
1. The heater must be connected to water main with at least 0.1 MPa
pressure; maximum pressure is 0.7 MPa.
NOTE:
In places or on the wall, where water may get to, the
power outlet installation height must be not less than
1.8 m.
2. G1/2 diameter pipes are used to connect the water heater to the water
pipeline.
3. To prevent a leakage when connecting pipes, use rubber sealing gaskets
on the threaded pipe ends.
4. Screw a relief valve to the inlet nozzle, marked blue and embossed arrow
of the water flow direction, so that the water flow direction coincides with
direction of the arrow on the valve’s case.
NOTE:
The water heater is the appliance, operating in such
a manner that pressure of water in the water heater
corresponds to the pressure of water in water main.
If pressure in the main exceeds 0.7 MPa, then it is
necessary to mount a pressure reducer before the
water heater so that pressure doesn’t exceed 0.7MPa.