www.timberk.com • electrical storage water heater
11
SWH RS1, SWH RS2 series
1. At first, open one of the discharge valves on the outlet of the water
heater, then open the inlet valve. The electric water heater will start filling
with water. When water flows from the outlet valve freely, it means the water
heater is fully filled with water and you can close the discharge tap.
Warning: During normal operation the inlet valve must be set «open».
2. Plug the power cord into the outlet, an indicator light will light up.
3. The appliance can automatically control water temperature. When
water temperature in the water heater reaches the temperature, set by the
user, the heating is automatically switched off, and water temperature will
be maintained due to the heat insulation layer; when water temperature
drops to a certain level, heating is automatically switched off, in such a
way continuous hot water supply is provided. When the water heater
automatically switches off, the indicator light goes out.
4. If you will turn the thermostat handle clockwise, you’ll increase the
temperature of heating. Maximum temperature inside inner tank is +75°C
approx. If you want to reduce the temperature of water, please, turn the
handle anticlockwise.
5. If you choose position of thermostat handle like «optimum» or « » , it
means you choose the most comfortable water tempe58 °(±2 °C).
9. WATER HEATER OPERATION
IMPORTANT!
Power outlet must be designed for rated current not
less than 10A, copper stranded power cord not less
than 3 x 1.5 mm
2
in cross section (for copper).
Power plug of the appliance represents a single unit
with GFCI*.
10. MAINTENANCE
1. Check the power plug and outlet as often as possible. Secure electrical
contact and also proper grounding must be provided. The plug and outlet
must not heat excessively.
2. If the water heater is not used for a long time, especially in regions with low
air temperature (below 0 °C), it is necessary to drain water from the heater to
prevent damage of the water heater (due to water freezing in the inner tank).
3. To ensure long reliable water heater operation, it is recommended to
regularly clean the internal tank and remove deposits on the electric heating
element of the water heater, as well as check condition (fully decomposed
or not) of the magnesium anode and, if necessary, replace it with a new one
in case of full decomposition.
Tank cleaning frequency depends on hardness of water located in this
territory. Cleaning must be performed by special maintenance services. You
can ask the seller for address of the nearest service center or find it on the
website www.timberk.com.
Fig. 11
Fig. 10
Fig. 12
IMPORTANT!
The manufacturer provides an extended guarantee
for particular water heater components provided that
timely and proper routine maintenance is performed
by specialists of an authorized service center (see the
guarantee card).