IM2020
14
EK1, EK2, EK3 –
heating element
M1 –
fan motor
SA1 –
operating mode switch
SK1 –
thermal limiter
SK2 –
thermostat
XP1 –
electrical plug
11. TROUBLESHOOTING
If it is impossible to fix these malfunctions with these methods, contact the authorized service center.
Malfunction
Possible cause
Solution
The device is connected
to the network but doesn’t work
No power
Check whether the power
supply is disconnected from
the device and, if necessary,
connect device to power supply
Defective operation mode switch
Contact an authorized service
center
Defective motor
Low heating temperature is set on
thermostat
Set the temperature higher on
thermostat by rotating the handle
clockwise
Faulty contact connection in
wiring scheme of electrical circuit
Contact an authorized service
center or restore reliable
contact connection
Temperature limiter parted
electrical circuit and shut off
the heating elements
Ensure that the air inlet or
outlet grille is not blocked by
foreign objects and wait for
turning on of the temperature
limiter, after the body of
the device cools down
Malfunction in circuit breaker
Change the circuit breaker
Power cord is broken
Contact an
authorized service center to fix it
The room temperature is higher
than the temperature set by the
thermostat
Turn the thermostat handle
clockwise until the heaters turn on
The device is connected to
electric network, heating mode is
set, the electric motor works, but
there is no heating
Low heating temperature is set on
thermostat
Set the temperature higher on
thermostat by rotating the handle
clockwise
Temperature limiter parted
electrical circuit and shut off
the heating elements
Ensure that the air inlet or
outlet grille is not blocked by
foreign objects and wait for
turning on of the temperature
limiter, after the body of
the device cools down
Defective operation mode switch
Contact an authorized service
center
Defective thermostat
Defective heating element
The room temperature is higher
than the temperature set by the
thermostat
Turn the thermostat handle
clockwise until the heaters turn on
Unnatural sound during operation
of the fan, vibration
The fastening of the fan parts has
loosened
Fas
ten fan parts or contact an
authorized service center
Содержание RE8 Series
Страница 1: ...ELECTRIC FAN HEATER INSTRUCTION MANUAL Models TIH RE8 2M TIH RE8 3M...
Страница 2: ...IM2020 2 1 2 1 2 3 1 4 5 0 C 2 6 7 8 9 10...
Страница 3: ...IM2020 3 11 12 13 14 15 180 16 17 18 19 20 21 22 23 93 24 25 26 30 60 27 28 3...
Страница 5: ...IM2020 5 6 1 1 2 1 3 1 4 1 7 1 2 1000 3 4 220 198 242 5 6 1 16 1 5 2 2 5 2 2 16 1 2 5 2 2 25 8 2...
Страница 6: ...IM2020 6 1 2 2 1 2 2 3 3 1 0 40 3 2 1 10 20 2 2 4 3 9...
Страница 7: ...IM2020 7 10 3 EK1 EK2 EK3 M1 SA1 SK1 SK2 XP1 11 2 2...
Страница 8: ...IM2020 8 12 13 1 2 30 C 50 C 15 85 5...
Страница 16: ...IM2020 16 www timberk ru...