background image

 

IM2020

 

14

 

 

EK1, EK2, EK3 – 

heating element

 

M1 – 

fan motor

 

SA1 – 

operating mode switch

 

SK1 – 

thermal limiter

 

SK2 – 

thermostat

 

XP1 – 

electrical plug 

 

 

11.  TROUBLESHOOTING 

If it is impossible to fix these malfunctions with these methods, contact the authorized service center. 

 

Malfunction 

Possible cause 

Solution 

The device is connected 

to the network but doesn’t work 

No power 

Check whether the power 

supply is disconnected from 

the device and, if necessary, 

connect device to power supply 

Defective operation mode switch 

Contact an authorized service 

center  

Defective motor 
Low heating temperature is set on 

thermostat 

Set the temperature higher on 

thermostat by rotating the handle 

clockwise 

Faulty contact connection in 

wiring scheme of electrical circuit 

Contact an authorized service 

center or restore reliable 

contact connection 

Temperature limiter parted 

electrical circuit and shut off 

the heating elements 

 

Ensure that the air inlet or 

outlet grille is not blocked by 

foreign objects and wait for 

turning on of the temperature 

limiter, after the body of 

the device cools down 

Malfunction in circuit breaker 

Change the circuit breaker 

Power cord is broken 

Contact an 

authorized service center to fix it 

The room temperature is higher 

than the temperature set by the 

thermostat 

Turn the thermostat handle 

clockwise until the heaters turn on 

The device is connected to 

electric network, heating mode is 

set, the electric motor works, but 

there is no heating 

Low heating temperature is set on 

thermostat 

Set the temperature higher on 

thermostat by rotating the handle 

clockwise 

Temperature limiter parted 

electrical circuit and shut off 

the heating elements 

 

Ensure that the air inlet or 

outlet grille is not blocked by 

foreign objects and wait for 

turning on of the temperature 

limiter, after the body of 

the device cools down 

Defective operation mode switch 

Contact an authorized service 

center  

Defective thermostat 
Defective heating  element 

The room temperature is higher 

than the temperature set by the 

thermostat 

Turn the thermostat handle 

clockwise until the heaters turn on 

Unnatural sound during operation 

of the fan, vibration 

The fastening of the fan parts has 

loosened 

Fas

ten fan parts or contact an 

authorized service center 

 

 

 

 

 

 

Содержание RE8 Series

Страница 1: ...ELECTRIC FAN HEATER INSTRUCTION MANUAL Models TIH RE8 2M TIH RE8 3M...

Страница 2: ...IM2020 2 1 2 1 2 3 1 4 5 0 C 2 6 7 8 9 10...

Страница 3: ...IM2020 3 11 12 13 14 15 180 16 17 18 19 20 21 22 23 93 24 25 26 30 60 27 28 3...

Страница 4: ...4 4 1 1 E TIH RE8 2M TIH RE8 3M 220 50 220 50 9 1 13 7 2000 3000 0 1000 2000 0 1500 3000 3 140 230 22 2 22 2 43 39 IP20 IP20 Class I Class I 3 5 4 0 250 220 340 250 220 340 TIH RE8 2M TIH RE8 3M 5 1 2...

Страница 5: ...IM2020 5 6 1 1 2 1 3 1 4 1 7 1 2 1000 3 4 220 198 242 5 6 1 16 1 5 2 2 5 2 2 16 1 2 5 2 2 25 8 2...

Страница 6: ...IM2020 6 1 2 2 1 2 2 3 3 1 0 40 3 2 1 10 20 2 2 4 3 9...

Страница 7: ...IM2020 7 10 3 EK1 EK2 EK3 M1 SA1 SK1 SK2 XP1 11 2 2...

Страница 8: ...IM2020 8 12 13 1 2 30 C 50 C 15 85 5...

Страница 9: ...with the power supply specifications 3 This appliance heats up to a very high temperature during operation To avoid burns do not touch the hot surfaces of the appliance with your hands and other parts...

Страница 10: ...ols ponds and in places where there is a possibility of falling into water or splashing water or water drops on the device 25 Do not place the device on unstable surfaces It is forbidden to install th...

Страница 11: ...ildings TIH RE8 3M model is intended for intensive heating and ventilation of building sites garages etc 5 DEVICE DESCRIPTION 1 Handle for moving 2 Control panel 3 Body of the device 4 Protection gril...

Страница 12: ...he wiring from overloads ATTENTION 1 The electric wire connected to the outlet from the power panel must have a core cross section of at least 2 5 mm 2 for copper wire 2 A circuit breaker designed for...

Страница 13: ...e device In this case make sure that the device is really defective and contact an authorized service center 4 Turning off Turn the thermostat knob fully counterclockwise and let the device run in ven...

Страница 14: ...ature limiter after the body of the device cools down Malfunction in circuit breaker Change the circuit breaker Power cord is broken Contact an authorized service center to fix it The room temperature...

Страница 15: ...the manufacturer s form The manufacturer and the authorized organization of the manufacturer remove responsibility for any possible harm which can be caused to people animals or property directly or i...

Страница 16: ...IM2020 16 www timberk ru...

Отзывы: