IM2020
12
3. Before connecting the device, make sure it is properly grounded. Proper grounding is important to
minimize electric shock and fire danger.
4. The device is designed to be connected to an alternating current electric network with a single
-
phase
voltage of 220V ~ (allowable voltage fluctuations from 198V~ to 242V~) and an earth loop.
5. To connect to the electric network, the device is equipped with a power cord with a plug.
6. To connect the device to the electrical network, insert the plug of the power cord into a socket with a
grounding wire.
ATTENTION!
1. The electrical outlet must be enough for rated current of at least 16A, and the electrical wire supplied to
the outlet from the power board must have a core section of at least 1.5 mm
2
for copper wire and at least 2.5
mm
2
for aluminum wires.
2. A circuit breaker designed for rated current of 16A must be installed in the power panel to protect the
wiring from overloads.
ATTENTION!
1. The electric wire connected to the outlet from the power panel must have a core cross section of at least
2.5 mm
2
(for copper wire).
2. A circuit breaker designed for a rated current of 25A must be installed in the power panel to protect the
wiring from overloads
8.
OPERATION OF THE DEVICE
Fig. 2*
*The appearance of the control panel may differ from the images in the manual
Operating mode selection knob
Used to select the following operating modes: ventilation mode
, low heating power
, high heating
power
Thermostat knob
Used to set the room heating temperature
Operation of the fan heater
1. Turning on
Make sure that the operating mode selection knob is set to
position, then connect the device to the
power source and set the operating mode selection knob to
position, the electric motor of the device will
turn on and the device will start operating in ventilation mode.
2. Heating power selection
2.1. Set the operating mode selection knob to
position to select low heating power mode.
2.2. Set the operating mode selection knob to
position to select high heating power mode.
Содержание RE8 Series
Страница 1: ...ELECTRIC FAN HEATER INSTRUCTION MANUAL Models TIH RE8 2M TIH RE8 3M...
Страница 2: ...IM2020 2 1 2 1 2 3 1 4 5 0 C 2 6 7 8 9 10...
Страница 3: ...IM2020 3 11 12 13 14 15 180 16 17 18 19 20 21 22 23 93 24 25 26 30 60 27 28 3...
Страница 5: ...IM2020 5 6 1 1 2 1 3 1 4 1 7 1 2 1000 3 4 220 198 242 5 6 1 16 1 5 2 2 5 2 2 16 1 2 5 2 2 25 8 2...
Страница 6: ...IM2020 6 1 2 2 1 2 2 3 3 1 0 40 3 2 1 10 20 2 2 4 3 9...
Страница 7: ...IM2020 7 10 3 EK1 EK2 EK3 M1 SA1 SK1 SK2 XP1 11 2 2...
Страница 8: ...IM2020 8 12 13 1 2 30 C 50 C 15 85 5...
Страница 16: ...IM2020 16 www timberk ru...