ТЕПЛОВЕНТИЛЯТОР ЭЛЕКТРИЧЕСКИЙ (ТЕПЛОВАЯ ПУШКА)

 

ELECTRIC FAN HEATER 

 

РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ 

INSTRUCTION

 

MANUAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Модели

/Models: 

 

TIH RE8 2M 

TIH RE8 3M 

Содержание RE8 Series

Страница 1: ...ELECTRIC FAN HEATER INSTRUCTION MANUAL Models TIH RE8 2M TIH RE8 3M...

Страница 2: ...IM2020 2 1 2 1 2 3 1 4 5 0 C 2 6 7 8 9 10...

Страница 3: ...IM2020 3 11 12 13 14 15 180 16 17 18 19 20 21 22 23 93 24 25 26 30 60 27 28 3...

Страница 4: ...4 4 1 1 E TIH RE8 2M TIH RE8 3M 220 50 220 50 9 1 13 7 2000 3000 0 1000 2000 0 1500 3000 3 140 230 22 2 22 2 43 39 IP20 IP20 Class I Class I 3 5 4 0 250 220 340 250 220 340 TIH RE8 2M TIH RE8 3M 5 1 2...

Страница 5: ...IM2020 5 6 1 1 2 1 3 1 4 1 7 1 2 1000 3 4 220 198 242 5 6 1 16 1 5 2 2 5 2 2 16 1 2 5 2 2 25 8 2...

Страница 6: ...IM2020 6 1 2 2 1 2 2 3 3 1 0 40 3 2 1 10 20 2 2 4 3 9...

Страница 7: ...IM2020 7 10 3 EK1 EK2 EK3 M1 SA1 SK1 SK2 XP1 11 2 2...

Страница 8: ...IM2020 8 12 13 1 2 30 C 50 C 15 85 5...

Страница 9: ...with the power supply specifications 3 This appliance heats up to a very high temperature during operation To avoid burns do not touch the hot surfaces of the appliance with your hands and other parts...

Страница 10: ...ols ponds and in places where there is a possibility of falling into water or splashing water or water drops on the device 25 Do not place the device on unstable surfaces It is forbidden to install th...

Страница 11: ...ildings TIH RE8 3M model is intended for intensive heating and ventilation of building sites garages etc 5 DEVICE DESCRIPTION 1 Handle for moving 2 Control panel 3 Body of the device 4 Protection gril...

Страница 12: ...he wiring from overloads ATTENTION 1 The electric wire connected to the outlet from the power panel must have a core cross section of at least 2 5 mm 2 for copper wire 2 A circuit breaker designed for...

Страница 13: ...e device In this case make sure that the device is really defective and contact an authorized service center 4 Turning off Turn the thermostat knob fully counterclockwise and let the device run in ven...

Страница 14: ...ature limiter after the body of the device cools down Malfunction in circuit breaker Change the circuit breaker Power cord is broken Contact an authorized service center to fix it The room temperature...

Страница 15: ...the manufacturer s form The manufacturer and the authorized organization of the manufacturer remove responsibility for any possible harm which can be caused to people animals or property directly or i...

Страница 16: ...IM2020 16 www timberk ru...