IM2021
27
2. The main socket must be designed for rated current of at least 10A and electric
cable with core cross section of at least 3x1.5 mm
2
(for copper).
3. The plug and socket must be kept dry to avoid electrical leakage.
NOTE!
Install the electric socket in places or on walls that may be splashed with water at a
height of at least 1.8 m.
Make sure that the electric plug is tightly connected to the socket on a regular basis.
Check it as follows: insert the electric plug into the socket, turn off the water heater
after 30 minutes of operation and remove the plug from the socket; check with your
hand whether the plug is hot. If the plug is hotter than 50
°C, replace the socket to
avoid damage, accidents, or fire due to poor electrical contact. Checks must be
conducted by a specialist.
RCD (residual current device)
not included in the delivery package.
1. Connect the power cord to the electric main; the indicator (1) will come on.
2. Press button (2) to test, voltage will not be applied, the indicator (1) will turn off and
the reset button (3) will go up.
3. To restart, press button (3), voltage will be applied again and the indicator (1) will
come on.
NOTE!
- if voltage is not disconnected and/or the indicator (1) does not turn off once you press
the test button (2), the RCD does not work properly.
- if voltage is not connected and/or the indicator (1) does not come on once you press
the reset button (3), the water heater does not work properly. In either case, disconnect
the water heater and call the service center.
- to reduce the risk of electrocution, do not disassemble, remove or pour liquid into the
product.