www.timberk.com • Electric drier for changing of air humidity
6
2. Mode Pad
Press to select the desired operation mode from ehumidifying, Dryer,
Continuous dehumidifying and Smart dehumidifying.
3/4. : Down/Up Pads
Humidity Set Control Pads.
The humidity level can be set within a range of 35%RH(Relative
Humidity) to 85%RH(Relative Humidity) in 5% increments.
For drier air, press the « » pad and set to a lower percent value(%).
For damper air, press the « » pad and set a higher percent value(%).
TIMER Set Control Pads
Use the Up/Down pads to set the Auto start and Auto stop time from
0.0 to 24.
5. Timer Pad
Press to initiate the Auto start and Auto stop feature, in conjuction with
the and key pads.
6. Turbo Pad
Control the fan speed. Press to select either High or Normal fan speed.
Set the fan control to High for maximum moisture removal. When the
humidity has been reduced and quiet operation is preferred, set the fan
control to Normal.
7. Ion Pad(optional)
Press to activate the ionizer. Anions ar automatically generated by
ionization. The anions deactive the airborne chemical vapors and dust
particles. Press it again to stop the function.
8. Display
Shows the set % humidity level from 35% to 85% or auto start/stop
time (0~24) while setting, then shows the actual ( ± 5% accuracy) room
% humidity level in a range of RH(Relative Humidity) to 90%RH(Relative
Humidity).
Error Codes and Protection Codes:
AS - Humidity sensor error--Unplug the unit and plug it back in. If error
repeats, call for service.
ES - Temperature sensor error-- Unplug the unit and plug it back in. If
error repeats, call for service.
P1 - Unit is defrosting-- Allow the unit time to automatically defrost.
The protection will clear after the unit self defrosts.
P2- Bucket is full or bucket is not in right position-- Empty the bucket
and replace it in the right position.
E3 - Unit malfunction-- Unplug the unit and plug it back in. If error
repeats, call for service.
EC -Refrigerant leakage detection-- With this new technology, the
display area will appear EC when the unit detects refrigerant leakage,
call for service.
Other features
Bucket Full Light
Glows when the bucket is ready to be emptied, or when the bucket is
removed or not replaced in the proper position.
Auto Shut OFF
The dehumidifier huts off when the bucket is full, or when the bucket is
removed or not replaced in the proper position.When the setting humidity
is reached, the unit will be shut off automatically. For some models,the fan
motor will continue operating.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off
and the fan will continue to run until the frost disappears.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart opertation in the first 3
minutes. This is to protect the unit. Operation will automatically start after
3 minutes.
Smart dehumidifying mode(optional)
At smart dehumidifying mode, the unit will automatically control room
humidity in a comfortable range 45%~55% according to the room
temperature. The humidity setting function will be invalid.
Auto-Restart
If the unit breaks off unexpectedly due to the power cut, it will restart with
NOTE:
On this operation,the unit can not be set humidity level.