background image

www.timberk.com • Electric air conditioner

www.timberk.com • Electric air conditioner

6

7

4. APPLIANCE DESCRIPTION

5. DELIVERY SET

6. APPLIANCE CONTROL

The conditioner consists of indoor and outdoor units connected by 

pipelines. The conditioner is controlled from a remote control board or from 

a control panel of the indoor unit. 

Complete set of air conditioner (split system) includes:
Conditioner unit for indoor installation  - 1 piece
Conditioner unit for outdoor installation - 1 piece
Remote control - 1 piece
Batteries for remote control board - 2 pcs.
Operator’s manual -1 piece
Warranty card- 1 piece
Packing of indoor-installation unit - 1 piece
Packing of outdoor-installation unit - 1 piece

The conditioner is controlled from a remote control board or from a control 

panel of the indoor unit.
Figure 2. Description of indoor unit control board
Control and indication board of your conditioner may visually differ from a 

layout view shown below. Its functions will remain the same.

18. Select-mode button “MODE”. Using this button, you may select a 

required mode: Auto, Cool, Dry, Heat, Fan.
19. Button “TEMP” (decrease/increase) for setting of the required air 

temperature from 16 to 32°С. Using this button, you may set the required 

air temperature indoors.
20. Button “ON/OFF”. Using this button, you may turn the conditioner on 

or off.
21. Button “FAN SPEED”. Using this button, you may select rotation speed 

of the indoor unit fan: “Auto”, “High”, “Middle”, “Low”.
In “Auto” mode the fan speed will change automatically. In dry mode the 

fan speed will remain unchanged  “Low”.  
22. Button “SWING”. Using this button, you may regulate position of air-

relief blinds and forward treated air to various directions. *
23. Button “AIR FLOW”. Using this button, you may turn the blind swinging 

on and off. *
24. Button “TIMER”. Using this button, you may set the time for turning the 

conditioner on and off (from 1 to 24 hours). If the conditioner is off, you may 

set the time for automatic turning on in a set time interval. And vice versa, if 

the conditioner is on, you may set the time for automatic turning off.
25. Button “SLEEP”. Using this button, you may turn the sleep mode on 

and off. In this mode the fan speed will be low.
26. Button “TURBO”. Using this button, you may turn the turbo mode on 

and off. In this mode the conditioner shows the maximum cooling (in cool 

mode) or heating (in heat mode) capacity. This mode cannot be used in 

modes: Auto, Dry, Fan. 
27. Button “HOLD”. Using this button, you may lock all other buttons of the 

control board, including the button on indoor unit control panel. To unlock 

this mode you should press this button once more. 
28. Button “CLEAN”. This button is not used for this series of conditioners.
29. Button “LAMP”. This button is not used for this series of conditioners.
Indication of the control board display shall correspond to selected modes.
Work with remote control board
Mounting and replacement of batteries: mount two LR03 alkaline batteries, 

according to polarity indicated on the remote control board.
In order to avoid malfunction of the remote control board do not insert used 

batteries or batteries of various types.

12. The receiver of infrared signals from the remote control.
13. Running indicator light.
14. Defrosting-Preheating indicator light.
15. The timer indicator.
16. Indicator alarm status.
17. Button controls in the absence remote control.
Emergency control shall be used if the remote control board is lost or 

broken, or batteries are low. Using an emergency control button (17, Fig. 

2) situated on the indoor unit control panel you may select COOL or AUTO 

mode of the conditioner work. Pressing this button, select a mode of the 

conditioner work: AUTO, COOL, the conditioner is OFF, AUTO again, etc.

1. Air outlet
2. Air inlet
3. Drain pipe
4. Liquid pipe
5. Gas pipe
6. Electric control cabinet
7. Hook
8. Indoor unit
9. Outdoor unit
10. Intake grilles outdoor unit.
11. Air discharge grill outdoor unit. 

1

9

8

8

8

2

7

6

3

5

4

2

1

4

5

3 6

7

9

10

11

11

11

10

1

7

5

4

6

3

1

2

RUN  DEFROST   TIMER   PROTECTION

EMERGENCY

14

13

12

15

16

17

18

20

21

24

26

19

22

23

25

27

28

29

Fig. 1

Fig. 2

Fig. 3

* not used for these models

Содержание AC TIM 18LC DT3

Страница 1: ...Outlook of devices aslo colour scores can be revised without any special advance notices AC TIM 18LC DT3 AC TIM 24LC DT3 AC TIM 36LC DT3 AC TIM 48LC DT3 AC TIM 60LC DT3 AC TIM 18LC DT3 O1 AC TIM 24LC...

Страница 2: ...life To repair the product contact an authorized service center 7 Do not use if it is defective or if it is dropped or damaged 8 Do not open the front panel of the device during its operation 9 Do no...

Страница 3: ...DT3 AC TIM 36LC DT3 AC TIM 48LC DT3 AC TIM 60LC DT3 Indoor unit AC TIM 18LC DT3 AC TIM 24LC DT3 AC TIM 36LC DT3 AC TIM 48LC DT3 AC TIM 60LC DT3 Outdoor unit AC TIM 18LC DT3 01 AC TIM 24LC DT3 01 AC TI...

Страница 4: ...a set time interval And vice versa if the conditioner is on you may set the time for automatic turning off 25 Button SLEEP Using this button you may turn the sleep mode on and off In this mode the fan...

Страница 5: ...rs or other chemically active substances Before a sustained interruption in the conditioner work Turn the conditioner on for several hours in the FAN mode It will allow you to dry its inner cavities S...

Страница 6: ...ized in accordance with norms regulations and procedures effective in the place of utilization 1 10 TRANSPORTATIOM AND STORAGE Temperature requirements Humidity requirements We are exploring new techn...

Страница 7: ...4 16 6 5 9 7 7 11 5 15 4 16 1900 2400 3800 5000 5700 1690 2100 3600 5100 5800 220 50 220 50 220 50 220 50 220 50 8 26 7 35 10 6 9 2 6 9 6 5 8 2 8 4 10 0 10 2 3 900 1200 1900 2300 2300 3 2800 3800 6000...

Страница 8: ...600 4000 18 43 18 43 18 43 18 43 18 43 7 24 7 24 7 24 7 24 7 24 32 0 33 0 44 0 45 0 45 0 41 0 52 0 92 0 99 0 99 0 36 0 37 0 48 0 49 0 49 0 43 0 56 0 100 0 110 0 110 0 1189x260x663 1189x260x663 1425x26...

Страница 9: ...FAN SPEED Auto High Middle Low Auto Low 22 SWING 23 AIR FLOW 24 TIMER 1 24 RUN DEFROST TIMER PROTECTION EMERGENCY 14 13 12 15 16 17 25 SLEEP 26 TURBO 27 HOLD 28 CLEAN 29 LAMP LR03 18 20 21 24 26 19 22...

Страница 10: ...timberk om 18 19 8 TURBO TURBO TIMER TIMER TIMER TIMER TIMER SLEEP SLEEP 1 2 2 8 SLEEP 2 1 2 2 8 SLEEP DRY ON OFF MODE DRY ON OFF Timberk Timberk www btpart ru www timberk com Timberk www btpart ru Ti...

Страница 11: ...ww timberk om www timberk om 20 21 www timberk com 26 TIMBERK TIMBERK 45 TIMBERK TIMBERK www timberk com 7 495 627 5285 www timberk com ru service timberk com TIMBERK 10 TIMBERK ID Timberk 25 TIMBERK...

Страница 12: ...www timberk om www timberk om 22 23 TIMBERK 3 c Timberk ID www timberk com 1 Timberk Timberk ID 171 21 12 2004 18 5 Timberk ID Timberk...

Страница 13: ...www timberk om www timberk om 24 25 1 1 2 3 Timberk Timberk ID Timberk Timberk Timberk www timberk com Timberk 25 502 11 19 01 1998 55 26...

Страница 14: ...www timberk om www timberk om 26 27 1 2 3 10 4 5 __________________________________ _____________________ ______________________________ 45 Timberk...

Страница 15: ...www timberk om www timberk om 28 29...

Страница 16: ...www timberk om www timberk om 30 31 TIMBERK c 10 www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com...

Страница 17: ...www timberk com...

Отзывы: