NOTICE.

The  unit  can  evaporate  condensed  water  and  automatically  drain  it 
through the hose*.
1. When the unit is in cooling mode, it is not necessary to install the 
condensate drainage pipe since condensate evaporates automatically. 
Make  sure  that  when  the  unit  is  operating,  the  rubber  plug  of  the 
drainage hose is securely fixed (see Fig. 10).
2. In heating mode, remove the rubber plug (2) of the drainage hose 
(Fig.  10),  install  the  respective  drainage  hose  to  improve  heating 
efficiency.
3.  In  dehumidification  mode,  remove  the  rubber  plug  (2)  of  the 
drainage hose, install the respective drainage hose.
Disconnect  the  air  outlet  hose,  connect  the  drainage  hose  to  the 
drainage  hole  and  drain  water  from  the  unit  to  ensure  maximum 
dehumidification efficiency.

E4  signal is shown on the LCD display at the maximum water level. 

To resume the operation, remove the rubber plug (2) of the drainage 
hose to drain water at first. After water is drained

Ðèñ. 10

Fig

.

 10

6.

 

Maintenance

IMPORTANT!

Disconnect the unit from the mains prior to cleaning.

1. When cleaning the air conditioner, do not use gasoline, solvents and 

other chemically active substances.
2. To avoid electric shock and damage to electrical components, do not 

pour water on the air conditioner from a tap or a hose.

*

not included

3. Do not use the air conditioner if the power cord is damaged. On the 

subject of replacing a damaged power cord, contact an authorized service 

center.

Air filter

Air filter clogging with dust particles impairs the air conditioner operation 

efficiency, therefore clean the filter no less than once in two weeks.

Filter removal/installation

Remove the air filter in the direction, indicated by the arrow. Slightly push 

it and then take it out from the device for cleaning. (See Fig. 11 and 12).

Fig

1

2

Fig

1

1

Installation of the filter is performed in the reverse order.

Filter cleaning

At first, carefully clean the filters by means of vacuum cleaners. Then 

immerse the filter in warm water (about 40°C) with a soft detergent, wash 

it and dry it without exposure to direct sunlight.

Air intakes (heat exchangers)

Use a vacuum cleaner for cleaning.
Case
Wipe the surface by a damp cloth and dry it by a soft dry cloth.

Automatic condensate removal

Condensate is automatically removed from the unit. Moisture inside the 

unit starts to evaporate and is removed from the unit through an air duct 

(or an air diffuser) in the form of steam.

18

10. 

 

 

 

 

 

 «Power» 

 

 

Ìèãàåò èíäèêàòîð çàïîëíåíè  åìêîñòè, ëîòîê 
äë  ñáîðà êîíäåíñàòà çàïîëíåí
Ôàêòè÷åñêà  òåìïåðàòóðà âîçäóõà â 
ïîìåùåíèè âûøå çàäàííîé (â ðåæèìå 
îáîãðåâà)

 

   

                                                                      

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 70°  

 

 

 

,   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   LCD-

 

 

E1

 

 

 

 

   

 

   

 

 

E2

 

 

 

 

 

 

   

 

 

   

 

 

E4

 

 

 

 

 

 

 

 

 

 

 

,   

 

 

 

 

 

.

 

 

   

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

   

 

,   

 

 

 

 

 

 

 

 

 

 

 

.

www.timberk.com

   

electric floor standing air  onditioner  ortable type (single case) 

www.timberk.com

   

 

 

 

 

 

 (  

 

)

Содержание AC TIM 12H P5BU

Страница 1: ...e revised without any special advance notices 17 18 17 18 Models AC TIM 12H P5BU AC TIM 12H P5R AC TIM 14H P5 AC TIM 14H P5R www timberk com Electric floor air conditioner portable type single case El...

Страница 2: ...be performed by a specialized company and qualifiedspecialists 2 PRECAUTIONS 1 Do not block vents 2 Make sure the inlet and outlet vent is not blocked 3 Do not insert foreign objects into the air dif...

Страница 3: ...nology as well as change its technical characteristics to improve its consumer and technical properties without prior notice Model AC TIM 12H P5BU AC TIM 12H P5R AC TIM 14H P5 AC TIM 14H P5R Capacity...

Страница 4: ...t the air outlethose theninsertitinthehole 2 Rotatetheairoutlethoseinthedirection indicatedbyarrow1andtakeit outfromtheremovablegrill 3 Rotate the air outlet hose in the direction indicated by arrow 2...

Страница 5: ...e Press the timer button when the unit is not operating to set the desired time buttons3and4 Theunitwillbeautomaticallyswitchedonwhenthesettimeexpires Press POWER button before the set time expires Ti...

Страница 6: ...eunitwillbeautomaticallyswitchedoff 3 Press ON OFF button before the set time expires Time setting will be canceledandtheunitwillbeswitchedoff 6 Automaticfanspeedbutton automaticventilationmode 7 High...

Страница 7: ...trical components do not pour water on the air conditioner from a tap or a hose not included 3 Do not use the air conditioner if the power cord is damaged On the subject of replacing a damaged power c...

Страница 8: ...inthesocketsecurelytoavoidoverheatingandriskoffire Donotpullthepowercordwithexcessiveforce itmaydamageit notincluded IMPORTANT At high humidity additional condensate removal will be required E4 symbol...

Страница 9: ...1 Short circuit on a temperature sensor or a processor board Contact an authorized service center E2 Short circuit between a copper pipe of the temperature sensor and the processor board wiring Contac...

Страница 10: ...4 5 5 6 7 6 8 7 9 8 9 9 9 10 10 11 11 6 7 8 9 10 11 1 2 3 4 5 6 15 3 4 ON OFF 4 SLEEP 1 SLEEP 2 1 2 SLEEP 2 2 3 4 3 3 5 9 E4 1 FUNC SET 2 TEMP 1 1 3 POWER 4 SLEEP 1 SLEEP 2 1 2 SLEEP 2 2 3 4 5 1 2 3 O...

Страница 11: ...11 7 0 17 32 0 5 23 8 9 10 3 5 11 10 12 13 14 15 1 2 1 50 1 2 2 3 DF 14 7 7 1 POWER 2 SET 3 TEMP 1 30 1 25 4 TEMP 1 17 1 15 5 LCD 7 3 4 POWER 1 8 2 3 4 6 7 5 6 SPEED www timberk com www timberk com...

Страница 12: ...X0 27 5 30 477x330x630 507x360x660 12000 3 5 12000 3 5 1480 1300 220 230 50 6 7 5 9 400 55 55 R410A B B I IPX0 27 5 30 477x330x630 507x360x660 14000 4 0 14000 4 0 1700 1500 220 230 50 7 7 6 8 450 70 5...