15
www.timberk.
com
i
nstant
water heater
Water Heater Operation
1. During the first water heater start-up or after long-term non-use, fill
the device with water by opening the cut-off tap at cold water
supply line, and make sure that there is a steady cold water flow at
water outlet at the consumption point, after that switch on the
device power supply, indicating lamp 1 at the control panel (see
Fig.15) starts blinking.
2. To switch on the device, press « » button at the control panel,
power supply indicator 1 (see Fig.15) will be constantly lit up.
3. Water temperature can be set 35° to +60° range with the
help of « » button (value increase) and « » (value decrease). If
water heater does not heat up to the temperature set, water flow
shall be reduced with the help of the tap at the inlet nozzle.
4. Water flow is controlled by the tap at water inlet to or outlet from
water heater. When there is water flow, and water pressure is not
less than 0.1 MPa, heating is switched on automatically, and
indicating lamp 2 located at the control panel lights up (see Fig.15).
5. After
heating
is
switched
on
,
you
need
to
wait
for
10-20
seconds
to
let
temperature
of
heated
water
stabilize
.
6. Incoming water is heated up inside the heating flask when it is
flowing through the heating element. Water temperature in the
water supply main may vary depending on a season from +3° to
+20° , so, in winter water flow shall be less than in summer to
assure the optimum water temperature.
To switch off the water heater, simply close water flow at the inlet
to or outlet from the device; electronic flow sensor automatically
opens the circuit of power supply to heating element, and
indicating lamp 2 located at the control panel goes down (see
Fig.15), and power supply indicator 1 starts blinking. For the
subsequent switching on of heating it is enough to reopen the
water supplying or water draining tap.
7. Temperature switch stops the power supply to heating element in
the event of water overheating inside water heater. If water heater
is connected to the electric main, and water heating is switched on,
ATTENTION
!
Do not switch on the water heater if there are grounds to suspect
that water inside it has frozen.
but water is not heated up, it means that the temperature switch
has tripped out or was not enabled. To return the water heater to
operating mode, the button at temperature switch shall be pressed.
Proceed as follows:
- Switch off the power supply to water heater, remove the front
panel, press the black button located in the central part of
temperature switch till it clicks; the temperature switch is located at
water heater flask.
ENGLISH
ATTENTION
!
If these activities have not resulted in any positive outcome or tem-
perature switch trips out repeatedly within a short period of time,
switch off power supply to water heater, close water supply to water
heater and address the Authorized Timberk Service Center located
at your region to receive any advice or maintenance. For the address
of the Authorized Service Center, please, consult with the seller or
visit our web-site at
.
www.timberk.com
Содержание 0 XTNZ1
Страница 5: ......
Страница 6: ......
Страница 19: ...19 www timberk com 6 7 8 9 10 11 12 13 14 15 16 17 18 19 27 20 IN OUT 21 22 23 24 35 25 26 ...
Страница 21: ......
Страница 22: ...3 ...
Страница 35: ...35 www timberk com Timberk Timberk 1 2 3 1 2 3 c 10 4 RU BY KG KZ UA AK TJ OS CIS ...
Страница 36: ...www timberk com 71 ...