IGNITION AND LIGHTING

 

 

Before the first firing, wipe all painted surfaces with a clean and dry cloth, in order to avoid 
burning of impurities on the stove and creation of unpleasant smells.

 

Start the fire in the stove by following order:   

 

• pull the primar air regulator handle counterclockwise to the maximum point

 

• secundary air regulator leave open untill the flame gets stabile and afterwards fire intensity 
control wih regulator 

   

 • open the firebox door

 

   

 • insert the firing material in the firebox (tiny chopped wood on dry wrinkled paper)

 

   

 • light the fire

 

   

 • close the firebox door,

 

   

 • after creating a basic glow in the firebox,  insert larger pieces of wood or coal,

 

     

 close the firebox door and push the handle of the draft regulator to the stove

 

     

 If fuel briquettes are used as a fuel, you must wait until entire amount of a fuel lightens up       

and only then reduce draft on half

 

   

 • when adding fuel,open the firebox door for just few degrees,wait for 4-5 seconds and 

then slowly open them wide. Do not open the door

 

suddenly, because when there is a high 

flame in the firebox, it can could easily reach in to room.

 

Regulating the draft in the stove, you can regulate temperature, power and the combustion of 
fuel. Recommended fuels are briquettes and wood.

 

You must not use gasoline and similar fuels, because by using liquid fuels you crate 
conditions for damaging the stove and to provoce an explosion.

 

 

Attention!

 

• Do not use organic wasteas fuel, food residue, plastic, combustible or explosive materials, 
which combustion disturbs the proper functioning of the cooker and may cause damage and 
environmental pollution.

 

 

• Increased ambient temperature can cause poor air circulation (drafts) in the chimney, and in 
that case is recommended more frequent firing in smaller quantities.

 

 

Содержание NIKA- HYDRO

Страница 1: ...NIKA HYDRO Fireplace stove on solid fuel Owners s manual INSTALATION ADJUSTMENT AND OPERATING INSTRUCTION EN 13240...

Страница 2: ...our stove Keep it handy and refer to it as needed You will find in it information that will be useful now and in the years to come Make sure that when installing the stowe all security standards have...

Страница 3: ...Bookmark not defined INSTALLING THE STOVE INTO THE SYSTEM FOR WATER HEATING Error Bookmark not defined Installaion on closed central heating system Error Bookmark not defined Installaion on opened cen...

Страница 4: ...g it Do not allow children to handle and play near the stove Only spare partes reccomended and allowed by the manufacturer should be installed on the stove You must not make any changes on the stove W...

Страница 5: ...The upper plate of the fireplace is made of steal figure 1 position 1 Firebox doors figure 1 position 4 are made of cast iron with fireproof glass Connection for smoke drain figure 1 position 2 is mad...

Страница 6: ...entral on upper plate Consuption by nominal power kg h 2 65 Emission temperature C 241 Air regulation Primary Automatski Rathgeber Secundary Manual Required amount of water in the boiler l 12 5 Requir...

Страница 7: ...eeply into the chimney that would reduce the cross sectional area and thus undermined draft in the chimney Do not use reducers which reduce the cross section of pipe smoke The stove requires insertion...

Страница 8: ...raft in the chimney Figure 3a check the chimney functioning The chimney should be located inside the building and if it s located on the external walls of the building it s highly recommended insulati...

Страница 9: ...ut 2 Excessive slope 3 A sudden change of direction of the channel 4 Stove or some other evice is connected to the same flue channel 5 Bulges in the channel 6 Cracks 7 Alien body or acumulated grime 8...

Страница 10: ...must wait until entire amount of a fuel lightens up and only then reduce draft on half when adding fuel open the firebox door for just few degrees wait for 4 5 seconds and then slowly open them wide D...

Страница 11: ...inserted only after the previous volume burn Do not allow that ashes and unburned accumulate on the grid and to ta pit that way Clean the grid Open the door slowly and carefully allowing that way equa...

Страница 12: ...clean the rost grid in order to provide the fresh air supply Regularly clean the ash tray making sure that there is always enough place for ashes The stove is designed to operate in periodic mode To...

Страница 13: ...ulation of secondary air Secondary air regulator put into position open Figure 7a during firing and keep in this position until establishing the stable operation of the stove after loading some larger...

Страница 14: ...ed to 4 bar The connecting line of the safety valve must be as short as possible and must not have the possibility of closing In this connecting line also there must not be any single valve or any oth...

Страница 15: ...Figure 8 closed central heating system...

Страница 16: ...ional service in charge that guarantees the correct operation of the entire heating system In case of bad design of the system and possible shortcomings while installing it by the entity that did the...

Страница 17: ...Figure 9 Open central heating system...

Страница 18: ...eaning use protective gloves Clean the bottom of the ovenfrom accumulated ash and pick up small unburned pieces of the grid clean the ashtray and ash accumulated in the interior of the fireplace Clean...

Страница 19: ...ke reenters into a room Closed regulator of air supply Insufficient draft Remainings of ashes on a grid Open the regulator of air supplyand provide a supply of a primary air Read carefully the instruc...

Страница 20: ...the manufacturer s service only If unauthorized persons carry out any servicing or repairs and alterations to the stove the owner loses the right to the manufacturer s warranty Supply of spare parts h...

Страница 21: ...is forbiden burning an inorganic and organic materials plastics plywood textile oiled wood etc because the combustion releases carcinogenic materials and other toxics FIREPLACE SOLID FUEL STOVE NIKA H...

Страница 22: ...cleaner structure 12 Authomatic regulation of a primar air 13 Pin 14 The base structure 15 Grid 16 Lever 17 Ashtray 18 Firebox door 19 Firebox door handle 20 Firebox door glass 21 Secondary air handl...

Страница 23: ...Dimensions of the stove...

Страница 24: ...the seller Detail protocol must be released by the offitial seller of TIM SISTE product This warranty will be accepted only if Product has been used according to this manual Product is not fisicaly d...

Страница 25: ...___________________________ __________________________________________________________________________ __________________________________________________________________________ ______________________...

Страница 26: ......

Страница 27: ......

Страница 28: ...TIM SISTEM d o o Prva industrijska 9 22330 Nova Pazova Serbia tel 381 22 328 076 e mail office timsistem rs www timsistem rs...