TECHNISONIC INDUSTRIES LIMITED
www.til.ca
TDFM-9100 Installation Instructions
TiL 13RE483A
2-23
CONDITIONS
SECTION
CATEGORY
COMMENTS
Decompression
4.6.2
50,000 feet
Overpressure
4.6.3
– 15,000 feet
Temperature Variation
5.0
B
+/– 5 degrees C per minute
Humidity
6.0
A
Standard Humidity Environment
Operational Shock and Crash Safety
7.0
A
Standard Operational Shocks
Vibration
8.0
S
Sinusoidal Vibration – curve M
S
Random Vibration – curve B
U
Sine-On-Random Vibration – curve G
Explosive Atmosphere
9.0
X
not tested
Waterproofness
10.0
X
not tested
Fluids Susceptibility
11.0
X
not tested
Sand and Dust
12.0
X
not tested
Fungus
13.0
X
not tested
Salt Fog Test
14.0
X
not tested
Magnetic Effect
15.0
Z
distance result was 0.21 meters
Power Input
16.0
B
see NOTE-2
Voltage Spike
17.0
B
Audio Frequency Susceptibility
18.0
B
Induced Signal Susceptibility
19.0
AC
Radio Frequency Susceptibility
20.0
T
see NOTE-1
Radio Frequency Emission
21.0
M
see NOTE-1
Lightning Induced Transient Susceptibility
22.0
X
not tested
Lightning Direct Effects
23.0
X
not tested
Icing
24.0
X
not tested
Electrostatic Discharge
25.0
A
10 discharge locations were used
Fire, Flammability
26.0
X
not tested
Other Tests
Remarks:
All testing was performed at Technisonic Industries unless otherwise indicated.
NOTE-1
Indicated test was performed by ULTRATECH LABS.
NOTE-2
Testing included subparagraph 16.6.1.3b: Requirement for Equipment with Digital Circuits.
Содержание TDFM-9100
Страница 2: ......
Страница 4: ...iv ...
Страница 35: ...TECHNISONIC INDUSTRIES LIMITED www til ca TDFM 9100 Installation Instructions TiL 13RE483A 2 24 NOTES ...
Страница 37: ......