TECHNISONIC INDUSTRIES LIMITED
RC-9100 Installation Instructions
TiL 14RE508 Rev. B Issue 1
11
NOTES
Страница 1: ...on Instructions TiL Document No 14RE508 Rev B Issue 1 NOVEMBER 2015 Technisonic Industries Limited 240 Traders Boulevard Mississauga Ontario L4Z 1W7 Tel 905 890 2113 Fax 905 890 5338 www til ca Copyright by Technisonic Industries Limited All rights reserved ...
Страница 2: ......
Страница 3: ...10 Changes made to DO 160G Operational Shock and Crash Safety changed to Category B Flammability Condition added Sep 09 2015 A L v Table of Contents was missing Subsections 2 6 1 to 2 6 8 and 2 7 1 to 2 7 5 All Page Numbers are now sequential All Corrected Spelling Grammar throughout document B iv Flammability Category C refers to Mod 6 only Nov 09 2015 A L 10 Added NOTE 3 to Environmental Qualifi...
Страница 4: ...TECHNISONIC INDUSTRIES LIMITED RC 9100 Installation Instructions TiL 14RE508 Rev B Issue 1 ii This page is intentionally left blank ...
Страница 5: ...ived including interference that may cause undesired operation WARNING AND DISCLAIMER Changes or modifications not expressly approved by Technisonic Industries could void the user s authority to operate the equipment This manual is designed to provide information about the RC 9100 Every effort has been made to make this manual as complete and accurate as possible WARRANTY INFORMATION The Model RC ...
Страница 6: ...by an effective Airworthiness Approval Technisonic has secured Supplemental Type Certificate STC approval The above referenced DO 160G test data is also on file and available from Technisonic to support approval requirements in airframes for which Technisonic does not possess an STC Approved aircraft types are listed in the attachments to the formal STC documents These STCs are the exclusive prope...
Страница 7: ...N GROUND PIN 1 J1 4 2 6 2 DEBUG PIN 2 J1 4 2 6 3 RESET PIN 3 J1 4 2 6 4 28 VOLTS DC PIN 4 J1 4 2 6 5 VCC PIN 5 J1 4 2 6 6 BACKLIGHT PIN 6 J1 4 2 6 7 TX AND RX DATA PINS 7 AND 8 J1 4 2 6 8 AUTO ON PIN 9 J1 4 2 7 POST INSTALLATION EMI TEST 6 2 7 1 PURPOSE 6 2 7 2 TEST CONDITIONS 6 2 7 3 METHODOLOGY 6 2 7 4 RESULTS 6 2 7 5 PROCEDURE 6 APPENDIX A Support Notes 9 ENVIRONMENTAL QUALIFICATION FORM 9 WARR...
Страница 8: ...TECHNISONIC INDUSTRIES LIMITED RC 9100 Installation Instructions TiL 14RE508 Rev B Issue 1 vi This page is intentionally left blank ...
Страница 9: ...It is a secondary slave control point and is not intended to replace the function of the front panel of the radio 1 3 TECHNICAL CHARACTERISTICS Specification Characteristic Model Designation RC 9100 Physical Dimensions Approx 5 75 x 3 x 1 3 Weight 12 oz 344g Operating Temperature Range 30 C to 60 C Power Requirement Voltage 28 0 VDC 15 Current 60 mA minimum 150 mA maximum Communication Protocol RS...
Страница 10: ...TECHNISONIC INDUSTRIES LIMITED RC 9100 Installation Instructions TiL 14RE508 Rev B Issue 1 2 This page is intentionally left blank ...
Страница 11: ...amage or warranty claims Check that each item on the packing slip has been shipped in the container 2 3 INSTALLATION The RC 9100 Remote Control is designed to be Dzus mounted and should be installed in conjunction with an IN RC91 installation kit See Figure 1 for an outline drawing of the unit with dimensions to facilitate the installation 2 4 INSTALLATION KIT CONTENTS The IN RC91 installation kit...
Страница 12: ...used for software updates at the factory 2 6 3 RESET PIN 3 J1 Do not connect This pin is also used for software updates at the factory 2 6 4 28 VOLTS DC PIN 4 J1 Connect to the 28 volt DC avionics bus through a 1 amp breaker 2 6 5 VCC PIN 5 J1 Do not connect This is a 3 3 volt output to supply the programmer for software updates at the factory Output current is rated at 200 mA 2 6 6 BACKLIGHT PIN ...
Страница 13: ...TECHNISONIC INDUSTRIES LIMITED RC 9100 Installation Instructions TiL 14RE508 Rev B Issue 1 5 FIGURE 2 Wiring Connections and Notes for the RC 9100 ...
Страница 14: ... navigation station Switch the RC 9100 on and off as often as required Observe the GPS for any degradation in satellite status or availability or flags Listen for any noise or detected audio signals on the VHF comm s Listen for any noise or detected audio signals on the VOR LOC receiver audio look for any movement of flags or needles on the VOR LOC GS navigation display s List the power plant fuel...
Страница 15: ...d other electric instruments not already included in the chart below and note any anomalies that occur due to operation of the RC 9100 Assess the results STEP SYSTEM PASS FAIL NOTES 1 Com 1 2 2 Transponder Encoder 3 ADF 1 2 4 VG 5 Glideslope 1 2 6 VOR LOC 1 2 7 Compass 8 Directional Gyro 9 Fuel Pressure 10 Oil Temp 11 Amps 12 Bus Voltage ...
Страница 16: ...D RC 9100 Installation Instructions TiL 14RE508 Rev B Issue 1 8 13 Fuel 14 Ng 15 TOT 16 Torque 17 Enunciators 18 Digital Clock 19 Oil Pressure 20 DME 1 2 21 GPS 22 Autopilot 23 Stability Augmentation Systems 24 Coupled ILS Approach ...
Страница 17: ...100 Part No 131281 1 2 Description Airborne Transceiver Remote Control Manufacturer Technisonic Industries Limited 240 Traders Blvd Mississauga Ontario Canada L4Z 1W7 Tel 905 890 2113 Fax 905 890 5338 Tested to RTCA DO 160G December 8 2010 Date Tested Feb xx 2014 March xx 2014 Test Report No 14RExxx CONDITIONS SECTION CATEGORY COMMENTS Temperature and Altitude 4 0 A2 B1 C4 D1 Low Temperature Survi...
Страница 18: ... 0 X Not tested Magnetic Effect 15 0 Z Distance result was 0 21 meters Power Input 16 0 B See NOTE 2 Voltage Spike 17 0 B Audio Frequency Susceptibility 18 0 B Induced Signal Susceptibility 19 0 AC Radio Frequency Susceptibility 20 0 T See NOTE 1 Radio Frequency Emission 21 0 M See NOTE 1 Lightning Induced Transient Susceptibility 22 0 X Not tested Lightning Direct Effects 23 0 X Not tested Icing ...
Страница 19: ...TECHNISONIC INDUSTRIES LIMITED RC 9100 Installation Instructions TiL 14RE508 Rev B Issue 1 11 NOTES ...
Страница 20: ... are changes or charges relating to the removal and re installation of equipment from the aircraft Technisonic will repair or replace at Technisonic s discretion any defective transceiver or part thereof found to be faulty during the Warranty Period Faulty equipment must be returned to Technisonic or its authorized Warranty Depot with transportation charges prepaid Repaired or replacement equipmen...