TIL RC-9000 Скачать руководство пользователя страница 13

TECHNISONIC INDUSTRIES LIMITED 

 

 

RC-9000 Operating Instructions 

TiL 13RE481 Rev. C 

 

2.6  

MODE KEY 

This  button  selects  USER  1  or  USER  2  mode  when  the  unit  is  installed  with  both  combined 
input/outputs  connected.  USER  1  or  2  will  be  indicated  at  the  bottom  of  the  display,  and  the 
selected band box will show yellow for USER 1 and blue for USER 2. 

 
 

2.7  

FUNC KEY 

Pressing the FUNC key will bring up the first functions menu. Consult the TDFM-9000 Operating 
Instructions for further details. 

 
 

2.8  

F1 to F4 KEYS 

Four  function  keys  at  the  top  of  the  keypad  (when  not  programmed  for  quick  channels  as 
mentioned above) provide the same actions as the three side buttons and the top button found on 
the APX-7000 portable. They are as follows: 

 

F1

 – Top-side-button (purple button) on the portable. 

F2

 – Centre-side-button (with one dot) on the portable. 

F3

 – Bottom-side button (with two dots) on the portable.

 

F4

 – Top button (orange button) on the portable. 

 
 

Consult the TDFM-9000 Operating Instructions for further details. 

 
 

2.9  

MUP(4) AND MDN(7) KEYS (Memory Up and Down Keys) 

These  keys  provide  the  same  function  as  the  rotary  knob  does  when  it  is  set  to  CHAN.  These 
keys can be used to scroll through the channels. A single press will step the channel by one, but 
a  push  and  hold  will  scroll  to  a  desired  channel  number.  The  function  of  the  rotary  knob  is 
automatically set to CHAN when either of these keys is pressed. 

 
 

2.10   UP(5) AND DN(8) KEYS 

The keys provide the same function as the left and right arrow keys on the portable. The UP key 
equates  to  the  right  arrow  key  and  the  DN  is  the  left.  These  keys  are  used  for  a  variety  of 
functions but in the normal operating mode, they are used to scroll through the soft key menus. 

 
 

2.11   BRT(6) AND DIM(9) KEYS 

Use  these  keys  to  dim  or  brighten  the  display.  The radio powers up at full brightness for normal 
use but can be dimmed for night operations. 

 
 
 
 
 
 
 
 
 

Содержание RC-9000

Страница 1: ... Operating Instructions TiL Document No 13RE481 Rev C SEPTEMBER 2015 Technisonic Industries Limited 240 Traders Boulevard Mississauga Ontario L4Z 1W7 Tel 905 890 2113 Fax 905 890 5338 www til ca Copyright by Technisonic Industries Limited All rights reserved ...

Страница 2: ...TECHNISONIC INDUSTRIES LIMITED RC 9000 Operating Instructions TiL 13RE481 Rev C ii This page is intentionally left blank ...

Страница 3: ...Env Testing Temperature Altitude category Fixed typo in STC Approval Note from DO 160F to DO 160G Oct 2013 H Duff B 3 Updated Figure 1 Corrected Arrows and Yellow Blue Bands which were reversed Jan 14 2014 A L 5 2 6 Corrected Yellow Blue Bands All Corrected Spelling Grammar throughout document C vi Changes made to DO 160G Operational Shock and Crash Safety changed to Category B Flammability Condit...

Страница 4: ...TECHNISONIC INDUSTRIES LIMITED RC 9000 Operating Instructions TiL 13RE481 Rev C iv This page is intentionally left blank ...

Страница 5: ...cluding interference that may cause undesired operation WARNING AND DISCLAIMER Changes or modifications not expressly approved by Technisonic Industries could void the user s authority to operate the equipment This manual is designed to provide information about the RC 9000 Every effort has been made to make this manual as complete and accurate as possible WARRANTY INFORMATION The Model RC 9000 Re...

Страница 6: ...plemental Type Certificate STC approval The above referenced DO 160G test data is also on file and available from Technisonic to support approval requirements in airframes for which Technisonic does not possess an STC Approved aircraft types are listed in the attachments to the formal STC documents These STCs are the exclusive property of Technisonic and require the written authority of Technisoni...

Страница 7: ... 2 FRONT PANEL 3 2 3 POWER 3 2 4 KNOB 4 2 5 SOFT KEYS AND HOME 4 2 6 BAND KEYS 5 2 7 FUNC KEY 5 2 8 F1 to F4 KEYS 5 2 9 MUP 4 AND MDN 7 KEYS Memory Up and Down Keys 5 2 10 UP 5 AND DOWN 8 KEYS 5 2 11 BRT 6 AND DIM 9 KEYS 5 2 12 ESW 0 KEY Ergo Switch Key 6 2 13 TSW KEY Toggle Switch Key 6 2 14 DISPLAY 6 2 15 GENERAL OPERATION 6 WARRANTY 7 FIGURE TITLE PAGE 1 Front Panel Controls RC 9000 Remote Cont...

Страница 8: ...TECHNISONIC INDUSTRIES LIMITED RC 9000 Operating Instructions TiL 13RE481 Rev C viii This page is intentionally left blank ...

Страница 9: ...rs It is a secondary slave control point and is not intended to replace the function of the front panel of the radio 1 3 TECHNICAL CHARACTERISTICS Specification Characteristic Model Designation RC 9000 Physical Dimensions Approx 5 75 x 4 5 x 1 3 Weight 16 oz 455g Operating Temperature Range 45 C to 60 C Power Requirement Voltage 28 0 VDC 15 Current 60 mA minimum 100 mA maximum Communication Protoc...

Страница 10: ...TECHNISONIC INDUSTRIES LIMITED RC 9000 Operating Instructions TiL 13RE481 Rev C 2 This page is intentionally left blank ...

Страница 11: ...e Zone Name Band Soft Keys For Band Selection and Menu Functions Key Pad Knob function and value Soft Menu Items below assume these The Soft Keys functions Power Switch can control Volume Channels and main Multifunction Knob Green Squelch Open Red TX User 1 User 1 or 2 indication X Power Indicator H FIGURE 1 Front Panel Controls RC 9000 Remote Control 2 3 POWER To switch the unit on momentarily pr...

Страница 12: ... will prompt you for an on or off entry using the soft keys to mute the tones Tones refer to the beeps heard when pressing buttons PWR Selecting PWR will allow the power output of the radio to be set to high or low PROG Selecting PROG brings you to user programmable features of the radio such as telephone numbers or scan lists The ability for the user to program phone numbers scan lists etc can be...

Страница 13: ...e F3 Bottom side button with two dots on the portable F4 Top button orange button on the portable Consult the TDFM 9000 Operating Instructions for further details 2 9 MUP 4 AND MDN 7 KEYS Memory Up and Down Keys These keys provide the same function as the rotary knob does when it is set to CHAN These keys can be used to scroll through the channels A single press will step the channel by one but a ...

Страница 14: ...n zone select or pl disabled mode 2 14 DISPLAY The transceiver has full colour LCD display The zone name channel name condition symbols scan direct call secure monitor etc and switch settings will be displayed for each module The active band as selected by the soft keys will be highlighted The bottom line displays the menu items associated with the module selected and the mode of the knob 2 15 GEN...

Страница 15: ...hanges or charges relating to the removal and re installation of equipment from the aircraft Technisonic will repair or replace at Technisonic s discretion any defective transceiver or part thereof found to be faulty during the Warranty Period Faulty equipment must be returned to Technisonic or its authorized Warranty Depot with transportation charges prepaid Repaired or replacement equipment will...

Отзывы: