TECHNISONIC INDUSTRIES LIMITED
www.til.ca
AMS-6000 Installation and Operating Instructions
TiL 03RE325 Rev n/c Issue 5
3-9
FIGURE 3-4
Wiring Diagram (Separate Mode)
3.6 HARDWARE INSTALLATION
The AMS-6000 is designed to mount in a standard 5.75" DZUS rail rack. See Figure 3-4 for
physical dimensions. The ‘Y’ harness is of sufficient length to allow the AMS-6000 to be
mounted directly above or below the TDFM-600/6000 series Transceiver. A new ‘Y’
harness will have to be fabricated if the AMS-6000 is to be mounted anywhere else. As
with all avionics installations, be sure to provide sufficient cooling or ventilation.
3.7 POST INSTALLATION TEST PROCEDURE
Follow the post installation procedure outlined in the TDFM-600/6000 Installation and
Operating Instructions. Check each transmit and receive button for proper function. Confirm
operation of the transmit and receive indicators. Test the REPEAT function to ensure there
is no interference from or to other equipment in the aircraft.
7.5 AMPS