background image

TECHNISONIC INDUSTRIES LIMITED 

www.til.ca 

 

 

AMS-6000 Installation and Operating Instructions 

TiL 03RE325 Rev n/c Issue 5

3-2 

 

3.3.2 Separate Mode 

 

In this mode, the TDFM-600/6000 and AMS-6000 will be connected to two or three 
positions on the existing audio panel. The ‘Y’ harness is used to connect the TDFM-
600/6000 transceiver to the AMS-6000 as well as to the aircraft audio system. The aircraft 
harness shall be wired as if it were to be plugged directly into the TDFM-600/6000 but 
instead will be plugged into the third connector on the ‘Y’ harness. 

28Vdc Power to the 

Transceiver is supplied directly via a separate 5A fused connection. 

See Table 3-2, Figure 3-

2 and Figure 3-4. 

 

 

 

FIGURE 3-2

 Separate Mode Installation 

 
 

3.4 

AMS-6000 15-PIN CONNECTOR PINOUTS (J2) 

 

The following are the pinouts for the 15-pin connector (J2) and the function of each pin. 

 
 

Pin # 

Description 

1 600 

Ohm 

Output 

2 No 

Connection 

Panel Lighting (28VDC or 5VAC) 

4 Memory 

UP 

5 Memory 

Down 

Mic Signal Input 

7 Main 

Power 

+28VDC 

8 Main 

Ground 

4 ohm Speaker Out 

10 

4 ohm / 600 ohm output ground 

11 No 

Connection 

12 No 

Connection 

13 

PTT (Ground Keying) 

14 Main 

Power 

+28VDC 

15 Main 

Ground 

 

TABLE 3-1

 Wire connections on a 15-Pin MALE D Connector (J2) 

 

Содержание AMS-6000

Страница 1: ...nstructions TiL Document No 03RE325 Revision n c Issue 5 AUGUST 2005 Technisonic Industries Limited 240 Traders Boulevard Mississauga Ontario L4Z 1W7 Tel 905 890 2113 Fax 905 890 5338 www til ca Copyright by Technisonic Industries Limited All rights reserved ...

Страница 2: ......

Страница 3: ...arate mode drawings for simplicity Corrected pinouts on drawings and tables Reference CR 07069 Issue 5 CR 10073 Global Incorporate New Document Template affecting Title Page Revision History headers and Footers adds Warranty page Corrected typo in Revision History page Figures 3 3 and 3 4 wiring diagram changes 5A fuse to 7 5A 29 07 2010 FM NOTE Editing may have caused pages to be added or re sequ...

Страница 4: ...This page left intentionally blank ...

Страница 5: ... authority to operate the equipment This manual is designed to provide information about the A790 Every effort has been made to make this manual as complete and accurate as possible WARRANTY INFORMATION The Model AMS 6000 is under warranty for one year from date of purchase Failed units caused by defective parts or workmanship should be returned to Technisonic Industries Limited 240 Traders Boulev...

Страница 6: ...elivered in the US and Canada as well as a number of single engine fixed wing aircraft The above referenced DO 160C test data is also on file and available from Technisonic to support approval requirements in airframes for which Technisonic does not possess an STC Approved aircraft types are listed in the attachments to the formal STC documents These STCs are the exclusive property of Technisonic ...

Страница 7: ...RUCTIONS 3 1 General 3 1 3 2 Equipment Packing Log 3 1 3 3 Wiring Instructions 3 1 3 3 1 Combined Mode 3 1 3 3 2 Separate Mode 3 2 3 4 15 Pin Connector J2 3 2 3 5 37 Pin Connector J1 3 4 3 6 Hardware Installation 3 9 3 7 Post Install Test Procedure 3 9 LIST OF FIGURES FIGURE TITLE PAGE 2 1 AMS 6000 Operator s Controls and Indicators 2 1 2 2 Smart RIB Cable Wiring Diagram 2 3 2 3 Key Loading Cable ...

Страница 8: ...TECHNISONIC INDUSTRIES LIMITED www til ca AMS 6000 Installation and Operating Instructions TiL 03RE325 Rev n c Issue 5 vi This page left intentionally blank ...

Страница 9: ...f an AMS 6000 If the AMS 6000 is used in the separate radio mode all three RF bands of the TDFM 6000 are connected to three different audio controller positions Receive indication on any of the three bands is annunciated on the AMS 6000 Transmit selection would be made via the audio controller in the separate radio mode Given that the TDFM 6000 will only display information about a single band at ...

Страница 10: ...utput in Separate mode TX Audio inputs TX Audio outputs Physical Dimensions Weight Mounting Operating Temperature Range Power Requirement Voltage Current Back Lighting Display Colour AMS 6000 3 Combined or Separate 500mW into 600 ohms 500mW into 600 ohms supplied by the TDFM 6000 0 145vrms 10 dBm nominal 0 145vrms 10 dBm nominal Approx 5 2 X 1 1 X 5 75 Approx 13 oz 370 g Panel Mount via DZUS faste...

Страница 11: ...ion 2 Displays squelch indication for each band in the TDFM 600 6000 simultaneously 3 Displays transmit indication for each band in the TDFM 600 6000 simultaneously 4 The ability to simulcast on any two or all three bands 5 The ability to cross band repeat between any two or all three bands 6 The program connector on the front panel allows for up or downloading of channels or encryption keys and i...

Страница 12: ...audio panel To simulcast on two or three bands the two or all three TX buttons will have to be pressed at the same time The RX buttons have a toggle on off function and provides the option of receiving multiple bands at the same time regardless of the TX button selection Selecting the REPEAT button while two or more TX buttons are selected will result in a simulcast condition and a repeat conditio...

Страница 13: ...2 3 PROGRAMMING CONNECTOR Mini DIN On the front panel of the AMS 6000 is an 8 pin mini DIN socket which provides access to the TDFM 600 6000 programming lines Through this connector channel information can be uploaded or downloaded to the transceiver The connector can also be used to upgrade the firmware in the transceiver modules and load encryption keys into units with encryption installed To pr...

Страница 14: ...TECHNISONIC INDUSTRIES LIMITED www til ca AMS 6000 Installation and Operating Instructions TiL 03RE325 Rev n c Issue 5 2 4 FIGURE 2 3 Key Loading Cable for the AMS 6000 TDFM 600 6000 P N 037348 1 ...

Страница 15: ...in combined mode The Y harness P N 077415 supplied with the AMS 6000 will be needed in either mode while a 15 pin D connector will also be required for a combined mode installation The following sections describe the specific wiring for each mode of operation IMPORTANT NOTE The Y harness PN 047394 has been replaced by PN 077415 The new harness does not support routing of the 28Vdc input supply for...

Страница 16: ...ugged into the third connector on the Y harness 28Vdc Power to the Transceiver is supplied directly via a separate 5A fused connection See Table 3 2 Figure 3 2 and Figure 3 4 FIGURE 3 2 Separate Mode Installation 3 4 AMS 6000 15 PIN CONNECTOR PINOUTS J2 The following are the pinouts for the 15 pin connector J2 and the function of each pin Pin Description 1 600 Ohm Output 2 No Connection 3 Panel Li...

Страница 17: ... dimmer bus to dim or brighten the front panel legend and indicators accordingly Note that the indicator lighting goes to full brightness when Daytime operation is selected This occurs when the dimmer bus voltage is turned off or drops below a minimum level e g 2v on 28v lighting system 3 4 3 Memory Up Memory Down Pins 4 5 Both pins are routed back out through the Y harness to the Transceiver Grou...

Страница 18: ...ection 22 PTT 1 4 No Connection 23 PTT 2 5 No Connection 24 PTT 3 6 No Connection 25 TX Audio Out 1 7 Ground 26 TX Audio Out 2 8 No Connection 27 TX Audio Out 3 9 Ground 28 Backlight Dimmer Bus 10 No Connection 29 Memory Up 11 No Connection 30 Memory Down 12 No Connection 31 LH DATA 13 No Connection 32 SB9600 BUSY 14 No Connection 33 OPT B 15 RX Audio 1 34 CTS OUT 16 No Connection 35 BOOT DIN 17 R...

Страница 19: ... controller when wired in the separate mode The PTT lines are bidirectional 3 5 6 TX Audio Out 1 2 and 3 Pins 25 26 27 The TX Audio Out lines are connected to the transceiver via the Y harness 3 5 7 Backlight Dimmer Bus Pin 28 The back lighting is connected to the transceiver via the Y harness If wired in the separate mode the back light signal comes in the third Y harness connector from the aircr...

Страница 20: ...TECHNISONIC INDUSTRIES LIMITED www til ca AMS 6000 Installation and Operating Instructions TiL 03RE325 Rev n c Issue 5 3 6 FIGURE 3 3 Wiring Diagram Combined Mode Continued on next page ...

Страница 21: ...TECHNISONIC INDUSTRIES LIMITED www til ca AMS 6000 Installation and Operating Instructions TiL 03RE325 Rev n c Issue 5 3 7 FIGURE 3 3 Wiring Diagram Combined Mode 7 5 AMPS ...

Страница 22: ...TECHNISONIC INDUSTRIES LIMITED www til ca AMS 6000 Installation and Operating Instructions TiL 03RE325 Rev n c Issue 5 3 8 FIGURE 3 4 Wiring Diagram Separate Mode Continued on next page ...

Страница 23: ...low the TDFM 600 6000 series Transceiver A new Y harness will have to be fabricated if the AMS 6000 is to be mounted anywhere else As with all avionics installations be sure to provide sufficient cooling or ventilation 3 7 POST INSTALLATION TEST PROCEDURE Follow the post installation procedure outlined in the TDFM 600 6000 Installation and Operating Instructions Check each transmit and receive but...

Страница 24: ...TECHNISONIC INDUSTRIES LIMITED www til ca AMS 6000 Installation and Operating Instructions TiL 03RE325 Rev n c Issue 5 3 10 FIGURE 3 5 Outline Drawing for the AMS 6000 ...

Страница 25: ...and re installation of equipment from the aircraft Technisonic will repair or replace at Technisonic s discretion any defective transceiver or part thereof found to be faulty during the Warranty Period Faulty equipment must be returned to Technisonic or its authorized Warranty Depot with transportation charges prepaid Repaired or replacement equipment will be returned to the customer with collect ...

Страница 26: ......

Отзывы: