16
TBX-440 Instruction Manual
Dec 2015
Refer to illustrations on pages 15 and 17.
1. Set POWER control to STANDBY. Always use this setting
when connecting the clamp or changing the tip.
2. Ensure the power cord is connected to a suitable 240V
AC power outlet and connected to the TIG Brush power
socket.
3. Turn the On/Off switch to ON. The switch should be
illuminated red.
4. Make sure the brush tip has its insulating shroud and the
insulation on the wand is undamaged.
5. Ensure the TIG Brush is switched on and all equipment is
correctly connected as described above in section 4.2.
6. Select power level and operating mode using the rotary
switches. See section 5 below for details.
7. Dip brush in cleaning fluid and apply brush tip to weld
area to be cleaned. Use only recommended cleaning
fluids, see S7.2.
8. Ensure brush and work area remain wet with the fluid
during cleaning.
9. Apply brush only for as long as necessary to remove
discolouration. Prolonged application may affect
surface quality.
10. Some light sparking may occur where brush tip contacts
workpiece, particularly on higher power settings, and this
is normal. Excessive sparking for a prolonged time in one
area may cause surface pitting.
11. When desired surface finish is achieved, turn the TIG
Brush Power Control to OFF.
12. After use put the brush down on a non-flammable
surface as it may be very hot.
13. Be careful touching the work as it may be hot.
14. Rinse thoroughly with clean water to remove all traces of
cleaning fluid. To ensure acidic residue is removed, use
the recommended Ensitech neutralising fluid, see S7.3.
S4 OPERATION
OPERATION
4.4
Содержание TBX-440