Using the Front Panel
TDR60 Procedures
This section provides detailed steps for performing various TDR60 tasks.
Saving a User Configuration
To save a user-defined configuration set:
1. Configure the TDR60 with the required parameters.
2. Once all parameters are correctly set, select Control>Configs>Save.
3. Use the Up or Down buttons to scroll through the list until the correct label
displays.
4. Press Enter. The configuration process may take up to one minute. When the
system has completed its configuration process, the asterisk will disappear.
Any configuration parameters previously stored under the selected label will be overwritten once the
save process is executed.
When you save a user-defined configuration, write down the configuration label (USER0, USER1,
or USER2) and all configuration settings that are saved under that label.
Time
Sets the time.
hh.mm.ss
where:
■
hh
= hours, in 24-hour format, as a value
between 0 and 23, (where 0 is midnight and 23
is 11 PM)
■
mm
= minutes; value between 0 to 59
■
ss
= seconds; value between 0 to 59
Control>Reset: used to reset the TDR60 to the last-saved configuration set. When a reset is performed, the TDR60 reloads all
programmable logic and firmware, restarts the unit, and clears the fault history log.
Press Enter to
reset
Resets the TDR60 to the last configuration set; reloads all
programmable logic and firmware; restarts the unit; and clears the
fault history log
Additional Information: As an aid to troubleshooting, the fault
history log should be reviewed and recorded before resetting or
turning the TDR60 power off.
Returns to MPEG2 Receiver/Decoder main menu
after reset
Control>RS232: used to configure the remote port
Baud
Sets the baud rate for the remote port
1200, 2400, 4800, 9600, 19200, 38400
Data Bits
Sets the number of data bits for the remote port
7, 8
Parity
Sets the parity for the remote port
None, Even, Odd
Stop Bits
Sets the number of stop bits for the remote port
1, 1.5, 2
Flow Control
Sets the remote port flow control.
■
soft flow control: software XON/XOFF (default)
■
hard flow control: hardware RTS/CTS
Version: used to display the version of firmware currently in use on the TDR60
Firmware
Query-only; displays the version of firmware currently in use on the
TDR60.
Firmware version
TDR60 Front Panel Menu Summary (continued)
Menu>SubMenu
Description
Parameters or Response Format
NOTE
NOTE
Содержание TDR60
Страница 10: ...viii 01 0868 401B 12 02 Preface...
Страница 14: ...4 01 0868 401B 12 02 TDR60 Overview...
Страница 48: ...38 01 0868 401B 12 02 Using a Remote Unit...
Страница 66: ...56 01 0868 401B 12 02 Technical Specifications...
Страница 74: ...64 01 0868 401B 12 02 QPSK Demodulator Application Notes...