TIDELAND TIBC-10 Скачать руководство пользователя страница 17

 

MAINTENANCE AND OPERATION MANUAL 

 

TIBC-10 011.1255-00   

 

Tideland Signal Corporation 

 

Page 12 of 14 

0111255-00REVA_TIBC-10MANUAL20SEPT11.doc 

ix.

 

Verify battery voltage is correct, and that all LEDs are GREEN. 

 

 

Figure 6 Adjustment Setup 

 
3. MAINTENANCE 

3.1 Routine 

Maintenance 

 

Since the TIBC-10 will always be used with a battery or batteries, the routine maintenance 
required is mainly that required for the batteries. 
 

 

Check the electrolyte in the batteries periodically to ensure proper level. 

 

 

Check the connections at the batteries periodically to ensure that they are clean and tight. 

 

Содержание TIBC-10

Страница 1: ...C 10 BATTERY CHARGER INSTALLATION and MAINTENANCE MANUAL PN 011 1255 00 Mike Kovalerchik Paul F Mueller Engineering Mgr Project Engr Checker A RELEASED FOR PRODUCTION 20SEPT11 PFM Rev Description Date...

Страница 2: ...MAINTENANCE AND OPERATION MANUAL TIBC 10 011 1255 00...

Страница 3: ...ent Procedure with Discharged Battery 11 2 4 3 Charger Alarm Level Calibration Procedure 11 3 Maintenance 12 3 1 Routine Maintenance 12 3 2 Field Service 13 3 3 Exploded Diagram and Spare Parts List 1...

Страница 4: ...ed a warning SHALL result in personnel injury or equipment damage WARNING Failure to heed this warning SHALL result in exposure to dangerous voltage CAUTION Failure to heed a caution MAY result in per...

Страница 5: ...delandsignal com Tideland Signal Limited Kendal House Victoria Way Burgess Hill Sussex RH15 9NF UK Phone 44 0 1444 872 240 Fax 44 0 1444 872 241 E mail sales tidelandsignal ltd uk Tideland Signal Cana...

Страница 6: ...ked on a label GMU and explosion protected versions of the charger use the same panel layout and are configured in the same way The charger is available un housed as a panel product for use in user su...

Страница 7: ...20 to 90 RH Non condensing Panel version Over Temperature Protected Self resetting with hysteresis Cooling fan set to run at 60 C Battery Types Flooded Lead Acid Sealed AGM Lead acid Gelled Lead Acid...

Страница 8: ...redrilled with 3x 25 mm gland holes plugged for shipment See Figure 2 Mounting Dimensions Note No cable glands or bushings are provided with explosion protected enclosure All external wiring must comp...

Страница 9: ...MAINTENANCE AND OPERATION MANUAL TIBC 10 011 1255 00 Tideland Signal Corporation Page 4 of 14 0111255 00REVA_TIBC 10MANUAL20SEPT11 doc Figure 1 TIBC 10 Charger Panel View...

Страница 10: ...MAINTENANCE AND OPERATION MANUAL TIBC 10 011 1255 00 Tideland Signal Corporation Page 5 of 14 0111255 00REVA_TIBC 10MANUAL20SEPT11 doc Figure 2 Mounting Dimensions...

Страница 11: ...The TIBC 10 is set at the factory according to the sales order All settings are marked on a label An example label is shown in Figure 3 Configuration Label Figure 1 TIBC 10 Charger Panel View shows t...

Страница 12: ...andard Mains Color Coding Input power may now be applied to operate the TBC 10 2 1 1 Other connections There are a number of status outputs that are indications of charger health and are made availabl...

Страница 13: ...ised when healthy Ve EARTH GREEN DC Ve Earth Fault Alarm Energised when earth fault is detected Ve EARTH RED System Healthy Energised when healthy FAULT GREEN System Fault Energised when fault detecte...

Страница 14: ...ry is charged or nearly charged A higher current indicates charging Charging a deeply discharged battery may show the maximum current setting on the meter 2 3 Testing The charger is tested as follows...

Страница 15: ...t available a discharged battery can be used in an alternative procedure given below Start with the appropriate adjustment procedure to set the battery float voltage and maximum current levels During...

Страница 16: ...rrent level promptly to avoid overheating either the battery or the charger i Disconnect the AC mains supply and disconnect the battery ii Make the connections as shown in Figure 6 Adjustment Setup wi...

Страница 17: ...LEDs are GREEN Figure 6 Adjustment Setup 3 MAINTENANCE 3 1 Routine Maintenance Since the TIBC 10 will always be used with a battery or batteries the routine maintenance required is mainly that require...

Страница 18: ...are not located in a position where they are likely to be cut or broken Check the TIBC 10 to make sure there is no water in the enclosure and there is no corrosion on the terminals 3 2 Field Service...

Страница 19: ...10MANUAL20SEPT11 doc 3 3 Exploded Diagram and Spare Parts List Figure 7 Exploded Diagram Spare Part Part Number Description Fuse 15 Amp ATC 181 1194 00 FUSE ATC 15 Battery Charger 160 1021 00 BATT CH...