![Tibbo DS100 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/tibbo/ds100/ds100_tutorial_1114115009.webp)
9
•
Connect the power to the DS100/EM100SK and wait until it enters the Normal mode (Red and
Green Status LEDs blink three times)
•
Push the Setup Button (it is on the back of the DS100 and on the PCB of the EM100SK) - both
Status LEDs will start blinking (Red-Green-Red-Green-…)- the DS100 is now in the Serial
Programming mode (read all about it in
Section 4.2
. of the
DS100 Tech Manual
)
•
Try this command: in the
HyperTerminal’s
window press <Ctrl-B> (to mark the beginning of a new
command packet; the character on the screen will look like a smiley face), then capital “V” , then
<Enter>. The DS100 will respond with its firmware version string:
☺
V
☺
A<V2.20>
Input all other commands is a similar way: start every command with a <Ctrl-B> and finish it off by
pressing <Enter>. Note, that you cannot correct input errors by pressing <Backspace>, <
#
#
#
#
>, etc. If you’ve
made a mistake you have to start the whole command over again (press <Ctrl-B>, etc.).
2.5. Setting up the DS100/EM100SK
To make sure that all the Settings of the DS100/EM100SK are correct you are advised to initialize the
DS100 first. This will bring the DS100 back to its default factory state. After that, you only need to change
one Setting: IP-address of the DS100. Procedure below assumes that the desired IP-address is
192.168.100.40:
☺
I
/you initialize the DS100/EM100SK
☺
A
/OK
☺
SIP192.168.100.40
/you set new IP-address
☺
A
/OK
☺
GIP
/you verify new IP-address
☺
A192.168.100.40
/yes, it is 192.168.100.40