TIANJIN BAILI ERTONG MACHINERY QBR3 Скачать руководство пользователя страница 6

C. Manually close the valve; loosen the screw on the Closing Cam; in the direction of valve closing, to 

rotate the cam until a “crack” sound is heard, fasten the screws on the cam. 

D. Manually open the valve, making the Closing Cam to be away from micro switch’s contact. Then, 

electrically close the valve to check if valve’s closing position is precise. With a precise limit position and a 

sensitive control, user can fasten the screw on the Closing Cam. Loosening the screw is forbidden.(To 

adjust the cam if there is error with valve’s closing position and repeatedly check until requirement is met.) 

Adjustment for the closing position of valve. 

E. Manually operate the valve to the fully open position and unscrew the screw on the Open Cam; turn the 

cam to contact micro switch in the direction of opening valve as long as a “crack” sound is heard, user can 

fasten screw. (The steps below are the same with “D” and be care of the direction.) 

F. Electrically operate the valve for one stroke to make sure the controlling is in good condition. Check 

again if the screws on the cams are fastened firmly. Till now, adjustment for open stroke and closing stroke 

are finished. (See Fig.1) 

3.2Adjustment for the pointer and potentiometer 

A. When the valve is at a limit position, unscrew the pointer’s screws to have it pointed at the 

corresponding scale and then fasten the screw. See Fig.1 

B. When the valve is at a limit position(fully open or closed), uplift the potentiometer’s gear to make it to 

be separated. Then, fasten the screws; rotate the potentiometer to the corresponding valve position 

(potentiometer rotates to the end position) and go back a little. Unscrew the screw on the potentiometer’s 

gear and make it to be meshed. To confirm it is meshed before fasten the screw.(Take care of the limit 

position ,or it would be damaged.)   

3.3Adjustment for the mechanical limit screws 

A. To make sure in which valve position the screw limits before adjusting the mechanical limit screw. 

While turning the valve right is to close, the limit screw on the right side is closing limit and the limit screw 

on the left side is open limit. 

B. When the valve is adjusted on a limit position, rotate the screws inward until it touches the upper part of 

the driving shaft, and then, rotate back for 0.5-1 turn. Finally, fasten the outside screw and nut. Till now, 

adjustment for mechanical limit is finished. 

 

4. Additional Instruction for Explosion-proof product 

4.1 Instruction for explosion-proof type

 

QBR3Ex-QBR5Ex series explosion-proof type is produced on the basis of GB3836.1-2010

General 

Requirement for the Equipment Used in Explosive Environment, Part I

and GB3836.2-2010 

The 

Equipment Protected by Explosion-proof Enclosure “d” Used in Explosive Environment, PartII

Meanwhile, this series have been tested, experimented and finally verified by the national verified 

explosion-proof organization and get Conformity Certificate of Explosion-Proof. 

The explosion-proof grade of QBR explosion-proof type is Ex d II B T4 Gb. Ex d II B T4 Gb---Class 

IIB, Temperature T4,Electrical apparatus. The sign “Ex” shows that the electric apparatus comply with the 

Explosion-proof Standard; “d” shows that the explosion-proof type is enclosure explosion-proof; II class 

represents that electric apparatus used in explosive gas environment except for gas made from coal; II B 

represents that the gas is ethylene; T4 indicates that the permissible surface temperature is 135

Gb is 

apparatus protection degree. 

There are 3 seating numbers and 6 types of this product: QBR3Ex

QBR3Ex.IN

QBR4Ex

QBR4Ex.IN

QBR5Ex

QBR5Ex.IN.  

Содержание QBR3

Страница 1: ...d this Operation Manual carefully before using this product SM 20 QBR3 QBR5 Quarter turn Electric Valve Actuator Operation Manual Tianjin Baili Ertong Machinery Co Ltd Former Tianjin No 2 General Machinery Factory ...

Страница 2: ...Content 1 Product instruction 1 2 Electric wiring 2 3 Product adjusting 3 4 Additional Instruction for Explosion proof product 4 5 Comprehensive test and notice 5 ...

Страница 3: ...e medium 1 2 9 Electric port total number of M33 1 5 is 2 1 3Majorstructureandfunction 1 3 1 Motor YDF specialized electric valve motor This kind of motor complies with relatednationalstandardanditstorqueperformancecomplieswithvalve sloadingperformance 1 3 2Reducermechanism it applies first class spur gear first class worm gear and first class NN type planetary reducer 1 3 3Limitcontrolandposition...

Страница 4: ...ensure that the cable will not influence other working parts in the control case 2 1 4 Put the sealing ring and gasket into the case s screw hole rotate gland nut and compress sealing ring so as to make it closely contact with cable s edge 2 1 5 Inner grounding and external grounding should be fixed and reliable 2 2 Wiring steps for explosion proof type of electric actuator see Fig 4 2 2 1 Remove ...

Страница 5: ... rain leaking into the electric actuator the first two connection patterns are right in the following picture 3 Product adjusting The torque mechanism has been tested and set up before delivered from the factory It complies with the maximum torque value written on the nameplate User does not need to readjust see Fig 2 Besides fasten two mechanical limit screws on the main case body It is better no...

Страница 6: ...s gear and make it to be meshed To confirm it is meshed before fasten the screw Take care of the limit position or it would be damaged 3 3Adjustment for the mechanical limit screws A To make sure in which valve position the screw limits before adjusting the mechanical limit screw While turning the valve right is to close the limit screw on the right side is closing limit and the limit screw on the...

Страница 7: ... Besides the Manual Operation a copy of electric schematic diagram has been provided User shall strictly follow the terminal diagram while wiring Wiring lug shall be applied The wiring lug shall not exposed or loosened Uplift the plastic jacket of the wiring lug same direction to make sure an appropriate leakage distance Any electric conductor cannot be left in the wiring case 5 Comprehensive test...

Страница 8: ...inal protection function in the above conditions 2 At the end of operation replace the cover When fastening the clamp nuts at wire inlet and outlet make sure that no adverse elements such as severe damp water and dust etc that could weaken protective performance left in the inner space 3 In the course of mounting covers make sure that rubber seal rings are not damaged and fasteners are securely sc...