1.4 Major components and function 

1.4.1Motor: Input power supply of electric actuator. YDF specialized motor for electric valve. 

Technical parameters comply with related national regulations. Its torque performance complies 
with valve’s loading performance. 

1.4.2 Reducer: NQB1 and NQB1.IN applies one stage spur gear pair and two stages worm gear 

pair. For NQB2 and NQB2.IN, NGW planetary reducer is added to the lower part of NQB1 and 
NQB1.IN. The range of output speed of the above products is wide and the output shaft has a good 
self-locking function. 

1.4.3Stroke control and position indication mechanism: they are used to control valve’s end 

position and they send electric contact signal of position to control room. They can indicate 
valve’s position on site and send consecutive electric signal of the position to control room. This 
mechanism composes of stroke cam, micro switch, dial and potentiometer. Adjustment against 
this mechanism shall be made after electric actuator is combined with valve. 

1.4.4 Torque control mechanism: it is used to protect electric actuator and valve when overload 

at the valve side happened. Torque signal comes from the axial displacement generated when the 
axial force on the worm compresses the disc spring. The torque switch is composed of cam and 
micro switch. User does not need to re-adjust this mechanism since it has been set up before 
factory delivery. 

1.4.5 Manual/Electrical switching handle and manual mechanism: Used for the manual 

operation under the repair, commissioning and emergency state. Adoption of semi-automatic 
electrical priority mode, the operation method is to push the switching handle arm and hold its 
position to complete the Manual/Electrical switching handle, rotate the handle to carry out manual 
operation; release the switching handle arm after the manual operation, this mechanism will return 
to the electrical position (When pushing the switching handle arm, the handle may be rotated 
properly to make the internal mechanism engaged). 

1.4.6 Mechanical limit mechanism: used to restrain the limit position of the output shaft. Since 

it has been adjusted before factory delivery, it should not be loosened at will in case of 
over-adjustment disengage the worm segment and worm. The mechanical limit of NQB2 and 
NQB2IN is on NGW planetary reducer. 

1.4.7 Spline joint: used to connect valve worm and output shaft of electric actuator. This can be 

easily taken out and be processed according to the dimension of worm’s hole and key, which is 
beneficial for the mount and dismantle for the valve against electric actuator. 

1.4.8 Integral controller: for the integral type of this product (NQB1.IN, NQB2.IN), the integral 

controller is a part of the main product body. There is AC contactor and other electric components 
in this controller. There are switching buttons, control buttons, and valve position signal on the 
product’s body cap. 

1.4.9 Sealing wire plug: used for the introduction of power cable and control cable. It can 

ensure the sealing performance of the electric wiring of electric actuator. The input sealing wiring 
plug of the standard type product is on the main body of actuator. For the integral type, it is in the 
integral controller. For the explosion-proof type and integral, explosion-proof type of electric 
actuator, the sealing input wire plug is in the wiring box. 

1.4.10 Wiring terminal board: used to connect the wires with power cable and control cable. For 

the standard type of product, the wiring terminal board is in the stroke and torque control cavity; 
for the integral type of product, it is in the wiring cavity which is at the back of integral controller. 

2.Product mounting 

2.1 Mounting position of electric actuator 

Electric actuator can be mounted at any position, but the following two positions are better. 
2.1.1 Vertical: the flange connected with the valve is parallel to the floor. That is, the center 

Содержание NQB1

Страница 1: ...0 SM 20 Please read this Operation Manual carefully before using this product NQB1 NQB2 Quarter turn electric valve actuator Operation Manual TIANJIN BAILI ERTONG MACHINERY CO LTD ...

Страница 2: ...Content 1 Product instruction 1 2 Product mounting 2 3 Electric wiring 3 4 Product debugging 4 5 Additional instruction for explosion proof type 5 6 Precautions 7 ...

Страница 3: ...elp to ensure that product mounting debugging and maintenance are dealt in right ways Please refer to Fig 1 Fig 4 for product outline For the dimension of the flange coupling with valve the dimension of driving shaft s whole and key refer to the Catalogue of the manufacturer Notify the specific technical parameters when ordering Please refer to product s nameplate for driving output power of the e...

Страница 4: ...echanism will return to the electrical position When pushing the switching handle arm the handle may be rotated properly to make the internal mechanism engaged 1 4 6 Mechanical limit mechanism used to restrain the limit position of the output shaft Since it has been adjusted before factory delivery it should not be loosened at will in case of over adjustment disengage the worm segment and worm The...

Страница 5: ...e of cables with connection wiring terminal board 3 and wiring should be reliable and shall not be exposed Pull the cable outwards in a proper amount to ensure it will not interfere with other operating components in the cavity Rotate the input sealing wire plug into the thread hole of the case body firmly screw the gland nut on the sealing wire plug so as to ensure the sealing performance of cont...

Страница 6: ...and the cam on the bottom is used to control close of the valve The adjustment of stroke control and position indication mechanism 4 1 1 Operate the valve manually to the neutral position 4 1 2 Start the electric actuator confirm that movement direction of the valve matches to the control when it is electrically controlled If there is any error change the phase sequence of the power supply this op...

Страница 7: ...er to the nameplate of the electric actuator is OPEN limit and CLOSE limit for the other one After the end position of the valve is decided adjust the screw inwards to make it contact with the limit section on the drive shaft first and then rotate it back by 0 5 to 1 turns At last tighten the retention screw or nut at outside this completes the adjustment of mechanical limit Note The limit screw i...

Страница 8: ...nameplate For the outline dimension flange dimension connected with valve and the position and dimension of inlet wire position of explosion proof wiring box please refer to the catalogue from our Company 5 2 Notice for usage and maintenance Refer to Fig 1 for the structure 5 2 1 Power must be cut off when actuator s any cover is open Please see the warning plate Forbid to open the box cover when ...

Страница 9: ...perating condition to determine whether to replace or replenish 6 3 After this product is removed from the valve for repairing or replacing the lubrication grease the stroke control and position indication mechanism should be inspected and adjusted The torque control mechanism should be inspected and calibrated if necessary making it be in accordance to the requirement 6 4 When using in the enviro...

Страница 10: ...8 Fig 1 Fig 3 Fig 2 ...

Страница 11: ...9 Fig 4 ...

Страница 12: ...d hole size and their positions should be specified Whether the hole for stem is required or not should be clarified Specify whether there is a special requirement or not such as explosion proof Introduce the operation condition in brief The controller should be specified separately when placing an order TIANJIN BAILI ERTONG MACHINERY CO LTD Address Block B No 180 Hanghai Road Tianjin Pilot Free T...

Отзывы: