background image

V.  

USING YOUR tia

• 

Install battery

Pull out gently but firmly on battery compartment cover on front of 

unit near trigger (Note that the cover remains attached by a hinge at 

the base of the handgrip. 

Attach standard 9V battery to connectors as shown inside the 

compartment

Nest battery inside the compartment

Close compartment

• 

Before first use or after changing the battery, wait 5-10 minutes for the 

device to warm up

• 

Push back hair from the forehead

• 

Wipe away any perspiration

• 

Avoid drafts (e.g. vents, another person’s breath, etc.)

• 

If a temperature change of the environment occurs, allow your tia NC-

9900 to reach current room temperature (about 15 – 20 minutes) before 

using

• 

Aim toward the forehead from 2 - 6 inches (5 -15cm) away.

• 

Press the trigger button and temperature is displayed in half a second.

• 

Note: temperature may also be taken from behind the earlobe. 

• 

Allow at least 15 seconds (1 minute is recommended) between 

measurements

VI.  SETTINGS

* During any setting functions, if your unit times out and goes 

back to its resting state, simply press the trigger and begin 

again.

1. Choosing Celsius or Fahrenheit as your Unit of Measure

• 

Press trigger to activate unit

• 

Select degrees Celsius by pressing the “°C” button, or degrees 

Fahrenheit by pressing the “°F” button 

• 

Wait several seconds

• 

Press trigger again to confirm selection and exit

6. Fahrenheit

7. Memory 

8. Celsius

9. Laser & backlight on/off

Содержание NC-9900

Страница 1: ......

Страница 2: ......

Страница 3: ...escription tia NC 9900 V Using your tia VI Settings o Unit of Measure o Alarm Setup o Body or Surface Mode o Total Variation o Laser Light Setup o Memory Data o Battery Changing VII Functions VIII Specifications IX Included with tia NC 9900 X Troubleshooting CONTENTS ...

Страница 4: ...not be used outside Do not drop Should a problem occur please contact the store where you purchased your tia Do not attempt to repair device yourself IMPORTANT SAFEGUARDS Do not dismantle MANUFACTURER RESERVES THE RIGHT TO ALTER SPECIFICATIONS WITHOUT PRIOR NOTIFICATION II INTRODUCTION The tia NC 9900 no contact thermometer has been developed with the latest infrared technology which allows tempor...

Страница 5: ...ays wait at least 15 seconds one minute is recommended between measurements PRACTICAL CONSIDERATIONS WHEN TAKING A TEMPERATURE In order to ensure that accurate consistent temperature measurements are obtained it is essential that each user become familiar with correct operation of the tia NC 9900 Keep in mind that taking someone s temperature is simple yet important Temperature should be taken und...

Страница 6: ...lower by 0 5 F 0 8 F 0 3 C 0 4 C than when standing NORMAL TEMPERATURES ACCORDING TO AGE 0 2 years 97 5 F 100 4 F 36 4 C 38 0 C 3 10 years 97 0 F 100 0 F 36 1 C 37 8 C 11 65 years 96 6 F 99 7 F 35 9 C 37 6 C 65 years 96 4 F 99 5 F 35 8 C 37 5 C IV DESCRIPTION OF tia NC 9900 1 Laser pointer lens 2 Infrared Sensor 3 Trigger 4 Battery compartment cover 5 Backlit LCD display 6 Fahrenheit 7 Memory 8 Ce...

Страница 7: ... the environment occurs allow your tia NC 9900 to reach current room temperature about 15 20 minutes before using Aim toward the forehead from 2 6 inches 5 15cm away Press the trigger button and temperature is displayed in half a second Note temperature may also be taken from behind the earlobe Allow at least 15 seconds 1 minute is recommended between measurements VI SETTINGS During any setting fu...

Страница 8: ...s F2 Press M button to display current setting Press C button to increase threshold by 0 2 F 0 1 C Press F button to decrease threshold by 0 2 F 0 1 C Confirm by pressing trigger Press trigger to exit Note Default value is 1 2 F 0 8 C Manufacturer recommends that you keep this setting Important Reminder Whenever there is a significant change in ambient room temperature please allow the tia NC 9900...

Страница 9: ...reen displays F1 o Press F button once to display F3 o Press M button to view current setting o Press F button to change from BODY to SURFACE or vice versa o Press M button to select desired choice of mode o Press trigger to exit 5 Laser and Backlight controls Press trigger to activate unit If laser beam is off press button once to turn back light on only Press button again to also activate laser ...

Страница 10: ...ss M button and then C button to view up to the 32 previous readings Note Display shows a count up from 1 to 32 in between temperature displays To view a count down from the 32nd reading down to the most recent follow the same procedure as above but press the F button instead of the C button To clear memory press and hold M button for approximately 3 seconds Press trigger to exit 7 Whenever you ar...

Страница 11: ...er use rechargeable batteries in the tia NC 9900 VII FUNCTIONS Specially designed to take the body temperature of a person regardless of the room temperature Quick reliable results as it uses the HEIMMANN infrared detection system Unique beep if temperature is exceeded Stores 32 previous measurements LCD back lit digital screen Data displayed in either Celsius or Fahrenheit Energy saving automatic...

Страница 12: ... the aorta via the carotid artery tia NC 9900 thermometer has been designed to produce an instant forehead temperature reading without any contact to the body The efficiency speed and comfort of taking a temperature in this way make it ideal VIII SPECIFICATIONS Normal operating conditions o 50 F 140 F 10 C 40 C o Humidity 80 Power 1 DC 9V battery Size L 6 3 x W 3 94 x H1 57 160mm x 100mm x 40mm We...

Страница 13: ...department at cs americocorp com Display shows temperature greater than 95 F oTemperature is in Fahrenheit oChange measurement to Celsius Press trigger to activate unit Press C button to change from Fahrenheit to Celsius Display shows body temperature less than 89 6 F 32 C o Thermometer is in SURFACE mode giving you a reading of external surface temperature o To take internal body temperature chan...

Страница 14: ...y to show LO Temperature reading is impeded by the presence of hair please brush away before measuring temperature Temperature reading is impeded by the presence of perspiration please wipe away before measuring temperature Temperature reading is skewed by the presence of air flow please use thermometer away from drafts Measurements are taken too rapidly please wait at least 15 seconds between mea...

Страница 15: ......

Страница 16: ......

Отзывы: