18
SME70-O-Manual-04-2020
A S S E M B L Y S E Q U E N C E
—
Required tools
The operations of assembling require the use of suitable tools:
• Hex Allen key 6 mm size (for fix extension sensors)
• Fixed wrenches (N.8 for junction box mounting, extension N.13 to tighten the nuts of extension
sensors, N.19 for fixing the CVS-P-24-O RGDAT to the shelf)
• Socket wrench N.19 (for use with the N.19 fixed wrench for fixing the CVS-P-24-O RGDAT to the shelf)
• Adjustable wrench for tightening the Nylon couplings to the sensors
• Phillips screwdriver PH2 for fixing the SME panel with M5 screws.
—
Mounting of CVS-P-24-O RGDAT sensors on the shelf
The fixing of the sensors must be made using the supplied components:
-n.6 screws M12x40 Stainless Steel - 2 for each sensor
-n.6 nuts M12 Stainless Steel - 2 for each sensor
-n.6 washers M12 Stainless Steel - 2 for each sensor
-n.6 grower washers M12 Stainless Steel - 2 for each sensor
—
Installation of couplings on the sensors
Verify that the connections and gaskets are correctly fitted; check that the connections are properly
tightened and eventually provide for clamping with the aid of an adjustable wrench.
n.1 support shelf
for sensors
n. 3 CVS-P-24-O RGDAT
P1
P2
flat gasket for DN28 M25 couplings