EZ Flow Cylinder Disconnect *Emergency Operation*(if equipped)
1.
Locate poppet valve buttons. (Fig A)
a.
Top Button (1) is for front door.
b.
Bottom Button (2) is for rear door.
2.
Push & hold each button individually for approx.
15 secs or until system is depressurized.
3.
When system has been depressurized, unlatch
quick release pin from clevis & remove. (Fig B)
Repeat this step on all cylinders as needed.
4.
Door(s) are now disconnected from the
cylinders and can now be operated manually
with crank handle if equipped.
Poppet Valves
(2)
Figure A
(1)
Figure B