Thunder TDR02026 Скачать руководство пользователя страница 8

8

DISPLAY

The top left icon shows current flow when the unit is charging the auxiliary battery and 

will be blue when any of the charging modes are charging the auxiliary battery. The 

top left icon will only turn green when solar input is charging the starting battery as 

seen in the image below.
The centre top of the LCD screen shows the selected Ah of the connected auxiliary 

battery, this must be adjusted pressing the “AH select” button on the bottom left 

corner of the LCD touch screen. The AH value increments by 5 Ah every time “AH 

select” is pressed.
The top right icon shows output current from anything connected through the shunt.
The oval shape progress bar on the middle of right side of the screen will show the 

time remaining until auxiliary battery is depleted along with the remaining hours before 

the connected auxiliary battery is depleted,(only when the shunt is connected) and 

also the percentage charged  left for the auxiliary battery.
The symbols on the middle of left side will indicate which charging process is 

currently activated, and will have the orange/red ring surrounding the current charging 

mode. If the current charging mode is 240VAC, and is switching to solar, the solar 

symbol will rotate to the top to indicate the current charging mode.
The voltage value shown in the middle of the screen (right next to current charging 

mode) is only for the auxiliary battery voltage.
The bottom right corner will only display a faulty battery icon if the auxiliary battery is 

detected to be faulty during stage 5.
The icon on the middle of bottom of the screen shows whether lithium battery 

charging has been activated or not and will only be displayed when the blue Lithium 

charging wire has been connected. 

Display unit parameters:

Input current displays: 0-30A
Output load current displays: 0-200A
Output voltage displays: 0-16V (Auxiliary Battery)
Auxiliary Battery Ah selected displays: 40-500 Ah (Each click increases 5Ah)
Auxiliary Battery percentage displays: 0-100%
Auxiliary Battery remaining lifetime: 0-100 hours

80

%

5

A

13.5

V

35

A

60

HR

100

AH

A/H

LITHIUM

AH SELECT

LITHIUM

BATTERY

FAULTY

BATTERY

80

%

5

A

13.5

V

35

A

60

HR

100

AH

A/H

LITHIUM

AH SELECT

LITHIUM

BATTERY

FAULTY

BATTERY

LCD screen with input charging icon turned 
green when charging starting battery and will 
turn blue when charging auxiliary battery.

Содержание TDR02026

Страница 1: ...For your personal safety read understand and follow the information provided in this instruction manual THANK YOU FOR CHOOSING THE THUNDER BATTERY MANAGEMENT SYSTEM...

Страница 2: ...Benefits 4 Installation 5 Operation 5 Charging Stages 7 LCD Display Operation 8 Display 9 Wiring 10 Specifications 11 Warranty Terms Conditions Copyright 2020 GPC Asia Pacific Pty Ltd ABN 97 097 993...

Страница 3: ...trol Over charging short circuit and over temperature protection Output reverse polarity protection Removable 3 5 inch Bluetooth colour LCD display with touch screen functionality Automatically switch...

Страница 4: ...um battery the Blue wire on the front of the TDR02026 will need to be connected to battery earth see specification table on page 9 If not charging a Lithium battery do not connect this wire Once corre...

Страница 5: ...ife 2 Soft Start The soft start function improves the batteries charging capability reduces gas and heat build up and can improve electrolyte consistency which can become uneven in the battery cells f...

Страница 6: ...g voltage and constant output current Stage 2 Perform constant voltage charging at 14 5V when current is lower than 3A switch to stage 3 Stage 3 Performs float charging with 13 5V If batteries voltage...

Страница 7: ...mote location of your choosing you can use the spare empty LCD case to install onto the main body of the unit where the original LCD screen was kept to keep the unit tidy Supplied with the unit are 2...

Страница 8: ...rently activated and will have the orange red ring surrounding the current charging mode If the current charging mode is 240VAC and is switching to solar the solar symbol will rotate to the top to ind...

Страница 9: ...Stud 12 24V Input Small Stud Solar Positive Input Front Wiring Red 12V Output Black 12V Earth output 12V input Earth Solar negative Blue wire Lithium Mode connect to earth Note Only connect the Lithiu...

Страница 10: ...put voltage 13V 50V Solar Regulator MPPT Auxiliary battery start charging voltage Battery voltage 0V Maximum Operating Temperature 55 C Display unit Bluetooth connection for removable LCD touch screen...

Страница 11: ...e the unit This warranty does not apply to failure or damage to a Thunder product caused by incorrect or faulty fitment accidental or intentional damage failure of other products incorrect application...

Страница 12: ...oria 3178 Australia 510 Mt Wellington Hwy Auckland New Zealand thunderauto com au thunderauto co nz GPC Asia Pacific 22 Enterprise Drive Rowville Victoria 3178 Australia 510 Mt Wellington Hwy Auckland...

Отзывы: