The Thunder 30A Battery Management System comes with a Bluetooth LCD interface 

screen, allowing you to have a better visibility of your batteries health and charging 

inputs. You can now monitor the health and usage of your battery allowing you to 

know what is charging your batteries and how long you have left until they are flat, 

At a glance you can tell if you need to start the generator or move the Solar to ensure 

you get the maximum input to your batteries. A lithium charging profile has been 

added so you can decide what battery system you would like to run.  If there is a fault 

with the auxiliary battery the LCD screen will show a fault symbol to let you know it 

has found an issue. 

The LCD screen is wirelessly paired with the TDR02026 using Bluetooth technology. 

The LCD screen can either be attached to the TDR02026 main unit or be remotely 

installed at a suitable location. The distance can be 8- 10m away from the main unit 

and must have a 12V power supply. 

The LCD screen has a light sensor in the top so when it senses the light reducing, the 

brightness of the display will also be reduced by 30%. 

When the main LCD screen is removed and installed in a remote location of your 

choosing, you can use the spare empty LCD case to install onto the main body of the 

unit where the original LCD screen was kept to keep the unit tidy.

Supplied with the unit are 2 types of power lead for the LCD display:

•  1 x 0.3M direct connection cable – a 0.3M cable can be pulled out from the LCD 

screen which can be directly connected to the TDR02026 main unit and moved 

0.3m from the main unit without requiring any 12V power, used in applications that 

do not have a separate power source convenient to power the LCD.

• 1 x 1.7m power cord – used to install the LCD screen at a suitable location and 

connect a 12V power source from ignition power or battery positive.

Note:

  Do not mount the LCD screen in direct sunlight. Doing so will cause damage  

to the screen.

LCD SCREEN OPERATION

1

4

3

2

10

9

12

11

8

7

5

6

1.  Input/Charging Current 
2.  Bluetooth active
3.  Battery Capacity
4.  Output/Load Current
5.  Charging Input Active
6.  Auxiliary Battery voltage

7.  Battery Percentage
8.  Time to Empty
9.  Battery Capacity setting button
10.  Lithium Mode
11.  Battery fault indicator
12.  Display switch

Display Screen

1. Press AH Select.
2.  By pressing the AH select button it will increase the AH by 5, increase the 

value to your desired level. 

3.  After you are happy with your AH level the TDR02026 will lock this figure in 

and begin to monitor.

Battery Amp Hour Setting Screen

Содержание TDR02026

Страница 1: ...For your personal safety read understand and follow the information provided in this instruction manual THANK YOU FOR CHOOSING THE THUNDER BATTERY MANAGEMENT SYSTEM...

Страница 2: ...Benefits 4 Installation 5 Operation 5 Charging Stages 7 LCD Display Operation 8 Display 9 Wiring 10 Specifications 11 Warranty Terms Conditions Copyright 2020 GPC Asia Pacific Pty Ltd ABN 97 097 993...

Страница 3: ...trol Over charging short circuit and over temperature protection Output reverse polarity protection Removable 3 5 inch Bluetooth colour LCD display with touch screen functionality Automatically switch...

Страница 4: ...um battery the Blue wire on the front of the TDR02026 will need to be connected to battery earth see specification table on page 9 If not charging a Lithium battery do not connect this wire Once corre...

Страница 5: ...ife 2 Soft Start The soft start function improves the batteries charging capability reduces gas and heat build up and can improve electrolyte consistency which can become uneven in the battery cells f...

Страница 6: ...g voltage and constant output current Stage 2 Perform constant voltage charging at 14 5V when current is lower than 3A switch to stage 3 Stage 3 Performs float charging with 13 5V If batteries voltage...

Страница 7: ...mote location of your choosing you can use the spare empty LCD case to install onto the main body of the unit where the original LCD screen was kept to keep the unit tidy Supplied with the unit are 2...

Страница 8: ...rently activated and will have the orange red ring surrounding the current charging mode If the current charging mode is 240VAC and is switching to solar the solar symbol will rotate to the top to ind...

Страница 9: ...Stud 12 24V Input Small Stud Solar Positive Input Front Wiring Red 12V Output Black 12V Earth output 12V input Earth Solar negative Blue wire Lithium Mode connect to earth Note Only connect the Lithiu...

Страница 10: ...put voltage 13V 50V Solar Regulator MPPT Auxiliary battery start charging voltage Battery voltage 0V Maximum Operating Temperature 55 C Display unit Bluetooth connection for removable LCD touch screen...

Страница 11: ...e the unit This warranty does not apply to failure or damage to a Thunder product caused by incorrect or faulty fitment accidental or intentional damage failure of other products incorrect application...

Страница 12: ...oria 3178 Australia 510 Mt Wellington Hwy Auckland New Zealand thunderauto com au thunderauto co nz GPC Asia Pacific 22 Enterprise Drive Rowville Victoria 3178 Australia 510 Mt Wellington Hwy Auckland...

Отзывы: