Solar Charging Mode

SOLAR CHARGING MODE

1.   Stage 1 - Direct Solar Energy: Charges the battery until the battery voltage 

reaches 14.5V, switches to stage 2.

2.   Stage 2 - Overpressure Pulse Charging: When the battery voltage is lower 

than 14.5V, charger pulses for one sec on and one sec off. This will occur 
for two hours, or until 14.5V average is reached (whichever comes first).  
Then will switch to stage 3. 

3.  Stage 3 - Pulse Floating Charge: Pulse one sec on, one sec off at 13.8V.

Содержание TDR02020

Страница 1: ...is specialty 12 Volt battery charger is a sophisticated multi stage charger utilising fully automatic computerised control designed to charge most 12 Volt Gel Lead Acid and Calcium batteries It is rec...

Страница 2: ...s 4 Important Safety Warnings 5 Installation 6 Specifications 7 Integrated LED Diagram 8 Wiring Diagram 9 8 Stage Charging Mode 10 Solar Charging Mode 11 Warranty Terms Conditions Copyright 2017 GPC A...

Страница 3: ...nd minimises temperature equating to longer battery life Unit will automatically change charge rate mapping for GEL AGM and standard Lead Acid Internal charger temperature monitoring and power output...

Страница 4: ...battery charger is not intended for outdoor operation Do not expose it to moisture or extreme weather conditions 8 If skin or clothing comes in contact with battery acid flush the affected area immed...

Страница 5: ...vehicle chassis If connecting a solar panel connect the positive from the panel to the solar input terminal and the negative of the panel to the negative terminal There is no need for an external reg...

Страница 6: ...ses over 17V the Thunder DC DC will shut off reset will be needed MIN AND MAXIMUM CHARGING VOLTAGES 13 1V 15 2V stops charging when alternator or vehicle battery below 12 2V SOLAR INPUT VOLTAGE RANGE...

Страница 7: ...e of charge and indicator lights These functions include Solar green LED Reverse polarity orange LED including alarm Faulty battery red LED NOTE The percentage display shows the stage at what the DC D...

Страница 8: ...mmended Not Supplied As your auxiliary battery charges its state of charge is reflected by the Thunder logo illuminating in 10 increments A percentage charge is also shown in green This percentage cha...

Страница 9: ...ter one minute If voltage is over 12 6V the Thunder DC DC goes to stage 6 Note If battery is determined to be faulty the Thunder DC DC will stop charge 6 Stage 6 Boost Stage Voltage up to max of 15 2V...

Страница 10: ...switches to stage 2 2 Stage 2 Overpressure Pulse Charging When the battery voltage is lower than 14 5V charger pulses for one sec on and one sec off This will occur for two hours or until 14 5V averag...

Страница 11: ...ir or replace the unit This warranty does not apply to failure or damage to a Thunder product caused by incorrect or faulty fitment accidental or intentional damage failure of other products incorrect...

Страница 12: ...12 GPC Asia Pacific Pty Ltd ABN 97 097 993 283 51 57 Qantas Drive Brisbane Airport QLD 4007 AUSTRALIA thunderauto com au thunderauto co nz...