Chapter 4: Connecting the system
The CAN backbone
33
4444
Co
n
n
ec
ti
ng t
h
e
sy
st
em
4.3 The CAN backbone
When connecting the CAN backbone, be aware of the following requirements:
•
The CAN bus is already terminated with 120
inside the GMDSS Terminal.
You must provide the CAN bus with a termination resistance of 120
at
the other end of the CAN backbone, either with a separate termination
resistance or inside the last device on the CAN backbone.
•
The cable length from each device to the CAN T-connector must be
maximum 6 m.
•
The total length of the backbone must be maximum 200 m.
•
The distance between the GMDSS Terminal and the power supply must be
maximum 55 m.
•
Make the ground connection to ship ground (hull) at the power supply -
and only there.
•
Connect the shield of the CAN cable to the connectors throughout the
system, but only connect to ship ground at the power supply.
Max.
6 m
Max.
6 m
Max.
6 m
Max.
6 m
Max. 200 m
120
120
here or
here
Max. 55 m
GND
(ship hull)
Содержание SAILOR 6110
Страница 1: ...INSTALLATION MANUAL SAILOR 6110 GMDSS System...
Страница 2: ......
Страница 3: ...SAILOR 6110 GMDSS System Installation manual Document number 98 130752 A Release date December 22 2010...
Страница 31: ...Chapter 3 Installing the system Mounting the SAILOR 3027 21 3333 Installing the system Horizontal pole...
Страница 36: ...Chapter 3 Installing the system 26 Mounting the SAILOR 1252 printer...
Страница 66: ...Chapter 5 Installation check and test 56 Generating a diagnostic report...
Страница 78: ...Glossary 68...
Страница 81: ......
Страница 82: ...98 130752 A Thrane Thrane A S info thrane com www thrane com...