The  safety  of  any  system  incorporating  this  equipment  is  the  responsibility  of  the  assembler  of  the  system.  If 
equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may 
be  impaired.  Only  with  written  consent  from  Thorlabs  may  changes  to  single  components  be  carried  out  or 
components not supplied by Thorlabs be used. There are no user serviceable components inside this device. 
 

 

 

Warning: Risk of Electrical Shock 

Before applying power to the instrument, make sure that the protective conductor of the 3 conductor 
mains power cord is correctly connected to the protective earth contact of the socket outlet. Improper 
grounding can cause electric shock with damage to your health or even death. Only use mains cable 
with sufficient current and voltage ratings for this instrument.

 

The local supply voltage must be in the 

range specified on the rear panel, and the correct fuse must be installed in the fuse holder. If not, please 
replace  the main  fuse  (see  Maintenance  Section).

 

Do  not  position  equipment  in  a  way  that  makes  it 

difficult  for  the  user  to  operate  the  disconnecting  device.

 

Do  not  remove  covers.  Refer  servicing  to 

qualified personnel. 

 

 

Warning: Risk of Explosion 

The instrument must not be operated in explosion endangered environments. 

 

 

Warning: Laser Radiation 

Avoid Exposure – Radiation emitted from apertures. Do not look into the 
laser  aperture  while  the  laser  is  on.  Injury  to  the  eye  may  result.  Laser 
should not be turned on unless there is an optical fiber connected to the 
laser output port. 
Caution  –  Use  of  controls  or  adjustments  or  performance  of  procedures 
other than those specified herein may result in hazardous radiation exposure. 

 

 

Caution: ESD Sensitive Component 

The components inside this instrument are ESD sensitive. Take all appropriate precautions to discharge 
personnel and equipment before making any connections to the unit. 

 

 

Caution: Components not Water Resistant 

This  instrument  should  be  kept  clear  of  environments  where  liquid  spills  or  condensing  moisture  are 
likely. It is not water resistant. To avoid damage to the instrument, do not expose it to spray, liquids, or 
solvents. 

 

 

Caution: Follow Intended Usage Guidelines 

Inputs and outputs must only be connected with shielded connection cables. 
 
Do not obstruct the air ventilation slots in housing. 
 
Mobile telephones, cellular phones or other radio transmitters are not to be used within the range of three 
meters  of  this  unit  since  the  electromagnetic  field  intensity  may  then  exceed  the  maximum  allowed 
disturbance values according to IEC 61326-1. 

 

 

Содержание TLX3

Страница 1: ...TLX3 O Band Tunable Laser Source User Guide...

Страница 2: ...tions 8 6 1 Manual Mode 8 6 2 Stepped Sweep Mode 9 6 3 Continuous Sweep Mode 10 6 4 Additional Utility Functions 11 Trigger and Sync Clock Outputs 14 7 1 Trigger Output 14 7 2 Sync Clock Output 15 Rem...

Страница 3: ...C connectors on the back panel provide analog output signals for synchronizing the operation of the laser to external instrumentation The laser has three main modes it can operate in Manual Stepped Sw...

Страница 4: ...not remove covers Refer servicing to qualified personnel Warning Risk of Explosion The instrument must not be operated in explosion endangered environments Warning Laser Radiation Avoid Exposure Radia...

Страница 5: ...icular installation This product has been tested and found to comply with the limits according to IEC 61326 1 for using connection cables shorter than 3 meters 9 8 feet Thorlabs is not responsible for...

Страница 6: ...nual Mode 100 ms Between Any Two Wavelengths Transition Time Step Mode 300 ms In Stepped Mode Dwell Time Step Mode 100 ms 60 s Does Not Include Transition Time Sweep Speed Range 50 400 nm s Continuous...

Страница 7: ...lso available for bench placement Callout Description A Power Switch B Indicator Light for Laser Power C Indicator Light for Laser Output D PM FC APC Fiber Output Callout Description A Main Power Conn...

Страница 8: ...ortcut should appear that looks like this 3 Connect the PC to the TLX3 laser via standard USB cable 4 Run the GUI application by clicking on the desktop shortcut 5 First select the COM port associated...

Страница 9: ...clicking on the radio buttons as shown in the image above 6 1 Manual Mode This mode as shown in the image above allows you to simply set the operating wavelength and step it manually using on screen b...

Страница 10: ...ant to sweep continuously then clicking on the Repeat menu will allow you to select Counted or Infinite sweeps Once the parameters are set the sweeps are initiated by clicking the Start Sweep button T...

Страница 11: ...h indicator labels on the wavelength scale The sweep speed and number of cycles to sweep can also be specified at the bottom of the GUI Similar to the Stepped Sweep Mode you can select whether the num...

Страница 12: ...ain Save Load The Save Load buttons can be used to store and recall the complete instrument settings for any particular mode of operation The settings are stored in a local directory on your PC as XML...

Страница 13: ...nd nothing else needs to be done If the Latest Version is newer then the Installed Version then the Download Update button will become active Simply press the button and follow the instructions Suppor...

Страница 14: ...13 TTN220723 D02 Help The Help button provides system information as well as several useful links to the TLX3 laser webpage the User Manual the Programming Guide and any License Documentation The TLX3...

Страница 15: ...ps to the next wavelength The rising edge indicates the beginning of the transition to the next wavelength then 300 ms later the falling edge indicates the laser is stable at the new wavelength In the...

Страница 16: ...signifies the laser is stable and external measurements can be reliably made The pulse width is variable and should be ignored The graph below shows the relationship between the Trigger and Sync outpu...

Страница 17: ...ation and the user s preference See the Programming Guide for information about the commands and connecting the laser to a PC https www thorlabs com manuals Pin Description 1 N C 2 Transmit Output 3 R...

Страница 18: ...O Band Tunable Laser Source Chapter 9 Mechanical Drawings Page 17 TTN220723 D02 Mechanical Drawings...

Страница 19: ...are no user serviceable components inside Optical patch cords used to connect to the front panel of the instrument should have their end faces cleaned every time a new connection is made The end faces...

Страница 20: ...he fuses for continuity If in doubt replace both fuses Additional replacement fuses can be purchased from Thorlabs or an electronics supply house Always use fuses of the same type as the original 5 Re...

Страница 21: ...please check the following items Ensure that the main AC receptacle has power Ensure that main power cable is fully seated at both ends Check the main power fuse see Maintenance Repair section Make s...

Страница 22: ...abs products such as Pure OEM products that means assemblies to be built into a unit by the user e g OEM laser driver cards Components Mechanics and optics Left over parts of units disassembled by the...

Страница 23: ...USA Canada and South America Thorlabs Inc sales thorlabs com techsupport thorlabs com UK and Ireland Thorlabs Ltd sales uk thorlabs com techsupport uk thorlabs com Europe Thorlabs GmbH europe thorlabs...

Страница 24: ...www thorlabs com...

Отзывы: