THORLABS SLSLLG2 Скачать руководство пользователя страница 6

Liquid Light Guide Adapter with Shutter

 

Chapter 3: Description 

Rev A, September 8,, 2016 

Page 3 

Chapter 3 

Description 

The SLSLLG2 Liquid Light Guide (LLG) Adapter with Shutter is designed to 
integrate with Thorlabs’ SLS301, SLS401, and SLS402 Light Sources. The LLG 
adapter couples the output of these light sources into Ø3 mm or Ø5 mm core liquid 
light guides. The adapter includes an integrated shutter, , focusing lens, a Ø3 mm 
LLG to SM1 Adapter, and a Ø5 mm LLG to SM1 Adapter. An external controller, 
switching power supply, AC cord, and manual are included with the LLG adapter. 

The shutter connects to the controller through a shielded four-conductor cable 
using a four-pin, mini-DIN connector. An included controller provides the drive 
levels required for optimal performance and monitors the state of the shutter. It 
features a BNC connector for external modulation and an interlock output jack for 
safety. A power supply (input AC 100-240V, output DC 5V) is included. 

The SLSLLG2 can also be directly controlled using either the buttons on the 
controller or via an external modulation source. Two buttons are on top of the 
controller unit, one turns the power on and off while the button labeled ENABLE 
opens or close the shutter. Manually depressing the ENABLE button will open and 
close the shutter. To use the modulation input, press and hold the ENABLE button 
for 3 seconds. The SLSLLG2 will power on in the last used mode, either Manual 
or External Modulation Mode. 

The external modulation port can drive the shutter up to a maximum frequency of 
15 Hz. In normal operation, when the voltage of the external modulation pulse is 
high, the shutter will open. When the voltage is low, the shutter will be closed. In 
normal operation, the shutter will shut down if it is operated at the maximum 
frequency for long periods of time in order to prevent overheating. In Unprotected 
Mode, this safety feature is disabled and the unit may be damaged if operated for 
long periods of time without thermal control. 

Along with overheating protection, the SLSLLG2 is equipped with laser and blade 
jam safety features. The controller detects the state of the shutter using an internal 
optical sensor inside the shutter package. An optical sensor detects the position of 
the shutter blade, confirming if the shutter is open or closed. This feature, when 
used with the interlock connector, is ideal for applications where a laser safety 
lockout is required. In the event of a failure such as a blade jam, the SLSLLG2 
shutter will shut down and the state of the interlock will be indicated by a red LED 
light. The SLSLLG2 shutter can detect when the blades are not operating at the 
set frequency and will shut down to prevent damage to the shutter.

Содержание SLSLLG2

Страница 1: ...SLSLLG2 Liquid Light Guide Adapter with Shutter User Guide...

Страница 2: ...djusting the Position of the LLG Adapter 7 4 3 Manual Shutter Operation 8 4 4 External Modulation Input 9 4 5 Protected Mode 10 4 6 Unprotected Mode 10 4 7 Default to On 11 4 8 Interlock Output 11 4 9...

Страница 3: ...quid Light Guide Adapter with Shutter 9 1 LLG Adapter and Shutter 20 9 2 Shutter Controller 21 Chapter 10 Regulatory 22 Chapter 11 Certificate of Conformance 23 Chapter 12 Thorlabs Worldwide Contacts...

Страница 4: ...ce Symbol Description Direct Current Alternating Current Both Direct and Alternating Current Earth Ground Terminal Protective Conductor Terminal Frame or Chassis Terminal Equipotentiality On Supply Of...

Страница 5: ...ere are no user serviceable parts in this product CAUTION DO NOT OPEN HOUSING The SLSLLG2 shutter and controller has no user serviceable parts Do not operate without cover installed WARNING Do not ope...

Страница 6: ...on will open and close the shutter To use the modulation input press and hold the ENABLE button for 3 seconds The SLSLLG2 will power on in the last used mode either Manual or External Modulation Mode...

Страница 7: ...Liquid Light Guide Adapter with Shutter Chapter 3 Description Page 4 CTN008800 D02 3 1 Overview Figure 1 SLSLLG2 Side View Figure 2 SLSLLG2 Mounted on SLS401 Light Source...

Страница 8: ...er Chapter 3 Description Rev A September 8 2016 Page 5 Figure 3 Controller Front View Figure 4 Controller Rear View Enable Button Status LED Power LED Power Button Interlock Jack External Modulation I...

Страница 9: ...AC DC switching power supply rated at 100 240 VAC 47 63 Hz and 5 VDC at 2 4 A maximum output 4 Place the controller on a flat surface Connect the mini DIN connector from the shutter head with the arro...

Страница 10: ...id light guide adaptor Item AD3LLG or AD5LLG to get the strongest light from the light source The adjustment can be done as shown in below 1 Use a spanner wrench Item SPW602 to loosen the retaining ri...

Страница 11: ...ning of the LED colors and modes please see the table on page 8 and page 12 Condition Shutter State Open Closed Depressing the ENABLE button Closes Opens Power plugged into either wall outlet or contr...

Страница 12: ...ted TTL signal connect the signal source to the shutter controller at the BNC TTL Input connector Activate the TTL signal source The shutter will be in the last state it was in when powered on therefo...

Страница 13: ...n this mode the unit will disable the blades turn the Status LED red and trip the interlock when the unit is run over 10 Hz and the time limit is reached see Specifications on page 15 for more informa...

Страница 14: ...act Thorlabs Tech Support if you believe your unit may need to be updated to include this feature 4 8 Interlock Output An interlock output is provided In the event of a failure the interlock circuit w...

Страница 15: ...n the mode When the Status LED turns red the device will shut down until the user cycles the power However when the device is in Unprotected Mode the Status LED will still turn amber 15 seconds before...

Страница 16: ...ully opening D E 15 17 Delay from fall of input pulse to initiation of shutter fully closing E G 9 11 Falling edge to 100 closed D G 24 26 Delay from fall of input drive to shutter fully closed Minimu...

Страница 17: ...delay from the initiation of the starting pulse to the shutter responding IA is typically 11 ms Similarly the closing time DE is typically 15 ms The mechanical rise time of the shutter is given as AC...

Страница 18: ...ecifications Specification Value Lens ACL5040U A Glass Type B270 Optical Crown Glass Wavelength Range 350 700 nm Effective Focal Length 40 mm Back Focal Length 26 mm Clear Aperture 45 mm Typical Coupl...

Страница 19: ...Hz 1 7 ms Typ 4 ms Max Jitter Falling Edge 10 Hz 1 7 ms Typ 4 ms Max Jitter Rising Edge 11 15 Hz 4 ms Typ 8 ms Max Jitter Falling Edge 11 15 Hz 4 ms Typ 8 ms Max Rise Time 10 ms Typ 12 ms Max Fall Tim...

Страница 20: ...e connector on the SLSLLG2 is a 4 pin Mini DIN shielded female connector that accepts the 4 pin Min Din male connector The pin descriptions are as follows Pin Description 1 Shutter Detect 2 Modulation...

Страница 21: ...ades to rust The SLSLLG2 use five blades for the shutter These blades are thin 0 003 and lightweight making them very delicate Please do not insert any objects into the shutter where the blades may be...

Страница 22: ...Protection Mode Status LED should be green under normal operating conditions and turn amber as a warning to state there is 3 minutes until shutdown at modulation frequencies of 11 to 15 Hz See Section...

Страница 23: ...Adapter and Shutter 62 0 mm 2 4 79 3 mm 3 12 61 9 mm 2 44 Cable Length 889 mm 1 0 mm of Adjustment Loosen Retaining Ring to Adjust 26 5 mm 1 04 SM2 2 035 40 Series External Thread 16 0 mm 0 63 Retaini...

Страница 24: ...Liquid Light Guide Adapter with Shutter Chapter 9 Mechanical Drawings Rev A September 8 2016 Page 21 9 2 Shutter Controller 3 00 76 2mm 3 42 86 7mm 3 50 88 9mm 1 38 35 1mm...

Страница 25: ...other Thorlabs products such as Pure OEM products that means assemblies to be built into a unit by the user e g OEM laser driver cards Components Mechanics and optics Left over parts of units disasse...

Страница 26: ...Liquid Light Guide Adapter with Shutter Chapter 11 Certificate of Conformance Rev A September 8 2016 Page 23 Chapter 11 Certificate of Conformance...

Страница 27: ...ormation USA Canada and South America Thorlabs Inc sales thorlabs com techsupport thorlabs com Europe Thorlabs GmbH europe thorlabs com France Thorlabs SAS sales fr thorlabs com Japan Thorlabs Japan I...

Страница 28: ...www thorlabs com...

Отзывы: