THORLABS OTM211 Скачать руководство пользователя страница 17

270&KDSWHU7KRUODEV:RUOGZLGH&RQWDFWV

5HY$2FWREHU

Page 1

Chapter 

  Thorlabs Worldwide Contacts 

 

USA, Canada, and South America 

Thorlabs, Inc. 
56 Sparta Avenue 
Newton, NJ 07860 
USA 
Tel: 973-300-3000 
Fax: 973-300-3600 
www.thorlabs.com 
www.thorlabs.us (West Coast) 
Email: [email protected] 
Support: [email protected] 
 

UK and Ireland 

Thorlabs Ltd. 
1 Saint Thomas Place 
Ely CB7 4EX 
Great Britain 
Tel: +44 (0) 1353-654440 
Fax: +44 (0) 1353-654444 
www.thorlabs.com

 

Email: [email protected] 
Support: [email protected] 

Europe 

Thorlabs GmbH 
Hans-Böckler-Str. 6 
85221 Dachau / Munich 
Germany 
Tel: +49-(0) 8131-5956-0 
Fax: +49-(0) 8131-5956-99 
www.thorlabs.de 
Email: [email protected] 
 

Scandinavia 

Thorlabs Sweden AB 
Bergfotsgatan 7 
431 35 Mölndal 
Sweden 
Tel: +46-31-733-30-00 
Fax: +46-31-703-40-45 
www.thorlabs.com 
Email: [email protected] 
 

France 

Thorlabs SAS 
109, rue des Côtes 
78600 Maisons-Laffitte 
France 
Tel: +33 (0) 970 444 844 
Fax: +33 (0) 825 744 800 
www.thorlabs.com 
Email:

 

[email protected] 

 

Brazil

 

Thorlabs Vendas de Fotônicos Ltda. 
Rua Riachuelo, 171 
São Carlos, SP 13560-110 
Brazil 
Tel: +55-16-3413 7062 
Fax: +55-16-3413 7064 
www.thorlabs.com

 

Email: [email protected] 
  

Japan 

Thorlabs Japan, Inc. 
3-6-3 Kitamachi, 
Nerima-ku, Tokyo 179-0081 
Japan 
Tel: +81-3-6915-7701 
Fax: +81-3-6915-7716 
www.thorlabs.co.jp

 

Email: [email protected] 
 

China

 

Thorlabs China 
Room A101, No. 100, Lane 2891, 
South Qilianshan Road 
Putuo District 
Shanghai 200331 
China 
Tel: +86 (0) 21-60561122 
Fax: +86 (0) 21-32513480 
www.thorlabschina.cn 
Email: [email protected] 

 

Содержание OTM211

Страница 1: ...OTM211 Optical Tweezer System User Guide...

Страница 2: ...erface 10 4 3 SDK 11 Chapter 5 Operating Conditions and Environmental Requirements 12 5 1 Selecting a Suitable Operation Environment 12 Chapter 6 System Connections and Care 13 6 1 Module Connections...

Страница 3: ...tion Direct Current Alternating Current Both Direct and Alternating Current Earth Ground Terminal Protective Conductor Terminal Frame or Chassis Terminal Equipotentiality On Supply Off Supply In Posit...

Страница 4: ...th Ensure that the line voltage switch is set correctly for your local supply and that the appropriate fuses are installed Fuses should only be changed by qualified service personnel The OTM211 contai...

Страница 5: ...nipulate micron sized dielectric particles in water Ashkin et al Optics Letters Vol 11 No 5 may 1986 This technique has become an important tool in a wide range of fields such as bioengineering materi...

Страница 6: ...In the Stokes method the sample is translated in a range of velocities A force balance between viscous drag on the particle and the trap force is computed 3 3 Key System Features Multiple traps with c...

Страница 7: ...0 x 1200 CCD Camera with Imaging Adapter Electronics Control Module Power Supply Module Nikon Eclipse Ti S Inverted Microscope with high resolution XYZ Piezo Stage Force Module Computer with Monitor a...

Страница 8: ...odule The optics module includes all the optical and opto electronic components for creating and controlling multiple optical traps The conditioned output beam is coupled into the microscope A schemat...

Страница 9: ...optics and power supply modules The bottom right of the front panel of the electronics control module has a key and an emergency shut off switch for the laser Three LEDs at the top are used to indicat...

Страница 10: ...will turn on 3 Turn the key switch on the Electronics Module to the ON position 4 Check the emergency stop button and make sure it is in the Enable position 5 Make sure all interlocks are closed 4 2...

Страница 11: ...can be set by clicking on the camera image The tool section allows the user to select information which will be display for the traps on the camera display such as the trap label and position The spee...

Страница 12: ...store or operate in damp condensing environments Do not expose to direct sunlight Do not use solvent on or near the equipment Keep away from dust dirt and air borne pollutants The system is not desig...

Страница 13: ...Module Power Supply 12 Interlock Cable to Microscope The Shutter Control cable NE Power Out USB Laser Control 1 and 2 Galvo Controls cables A B C and D for all four scanners are labeled on the Optics...

Страница 14: ...bs OTM211 Microscope Tweezers System can be offered in several configurations e g different wavelength optical power levels integrated with additional imaging modalities To achieve the listed specific...

Страница 15: ...0 2 Output Beam Shape Gaussian with M2 1 1 7 2 Power Requirements Power Specifications Voltage 120 240 V Maximum Power Consumption 1000 VA 7 3 Dimensions and Weights Dimensions and Weights Dimensions...

Страница 16: ...oducts such as Pure OEM products that means assemblies to be built into a unit by the user e g OEM laser driver cards Components Mechanics and optics Left over parts of units disassembled by the user...

Страница 17: ...rlabs com Scandinavia Thorlabs Sweden AB Bergfotsgatan 7 431 35 M lndal Sweden Tel 46 31 733 30 00 Fax 46 31 703 40 45 www thorlabs com Email scandinavia thorlabs com France Thorlabs SAS 109 rue des C...

Страница 18: ...www thorlabs com...

Отзывы: