LTS Series Long Travel Stages
7.3.2 Stage/Axis tab
Fig. 7.6 Stepper Motor Controller - Stage/Axis Settings
Stage and Axis Type
- For LTS series stages, the stage type is annotated
automatically when the stage is connected.
Min Pos
- the stage/actuator minimum position (typically zero).
Max Pos
- the stage/actuator maximum position.
Pitch
- the pitch of the motor lead screw (i.e. the distance (in millimetres) travelled per
revolution of the leadscrew).
Units
- the ‘real world’ positioning units (mm).
Note
This tab contains a number of parameters which are related to the physical
characteristics of the particular stage associated with the GUI panel. They need to
be set accordingly such that the stage is driven properly by the system.
For LTS series stages, the APT server will automatically apply suitable defaults for the
parameters on this tab during boot up of the software. These parameters should not be
altered subsequently, as this may adversely affect the performance of the stage.
For background information, the individual parameters are described in the following
paragraphs.
Caution
Extreme care must be taken when modifying the stage related settings that
follow. Some settings are self consistent with respect to each other, and illegal
combinations of settings can result in incorrect operation of the stage.