![THORLABS KSC101 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/thorlabs/ksc101/ksc101_user-manual_1110756029.webp)
29
K-Cube Solenoid Controller
Mode Buttons
- these buttons set the operating mode
of the unit as follows.
Note.
The captions for each mode are not displayed on
the GUI, and are provided here for reference only.
However, hovering the mouse over a particular button on
the GUI will generate a pop up window stating its function.
Manual
- In this mode, operation of the solenoid is via the top panel wheel, or
by the buttons on the GUI panel.
Single
- In this mode, the solenoid will open and close each time the top panel
wheel is moved, or the ‘Output ON’ button on the GUI panel is clicked. The ON
and OFF times are entered in the ‘Settings’ panel - see Section 6.3.
Auto
- In this mode, the solenoid will open and close continuously after the top
panel wheel is moved, or the ‘Output ON’ button on the GUI panel is clicked.
The ON and OFF times, and the number of cycles performed, are those
entered in the ‘Settings’ panel - see Section 6.3.
Triggered
- In Triggered mode, a rising edge (logic high) on rear panel TRIG
IN BNC input will open the shutter, which will remain open until a falling edge
(logic low) is detected. In this way, the shutter can be opened and closed in
relation to the duty cycle of the trigger input signal. The unit must be primed
(i.e. the top panel wheel has been moved up) before the unit can respond to
the external trigger.
Close and Open Buttons
- when manual mode is selected, these
buttons are displayed to close/open the solenoid. When the
solenoid is open, the associated Open LED
is lit.
Stop and Start Buttons
- when Single, Auto or Triggered mode
is selected, these buttons are displayed to stop and start the
solenoid sequence. When the Start button is pressed, the Active
LED
is lit. When the solenoid is open, the Open LED
is lit.
Cycle Parameters
- the present setting for the On and
OFF times.
These settings can be adjusted as described previously,
or by clicking the Settings button to display the settings
window, see Section 6.3.2.
Key Enabled
- Lit when the key-operated enable switch is
turned on.
Is Ready
- Lit when the unit is ready for use.