ELLB Distribution Board for Resonant Piezo Motor Products
Chapter 3: Operation
Rev C Jan 2020
Page 3
Chapter 3
Operation
3.1.
Environmental Conditions
Warning
Operation outside the following environmental limits may adversely affect operator safety.
Location
Indoor use only
Maximum altitude
2000 m
Temperature range
15°C to 40°C
Maximum Humidity
Less than 80% RH (non-condensing) at 31°C
To ensure reliable operation the unit should not be exposed to corrosive agents or excessive moisture, heat or
dust.
If the unit has been stored at a low temperature or in an environment of high humidity, it must be allowed to
reach ambient conditions before being powered up.
The unit is not designed to be used in explosive environments.
3.2.
Getting Started
Warning
The safety of any system incorporating this equipment is the responsibility of the person performing the
installation.
Caution
Although the module can tolerate up to 8 kV of air discharge, it must be treated as ESD sensitive device. When
handling the device, anti-static precautions must be taken and suitable discharge appliances must be
worn.
When power is applied, do not connect or disconnect the ribbon cable connecting the interface board to the
distribution board. Always remove power before making connections.
The ribbon cable connector is made of plastic and is not particularly robust. Do not use force when making
connections. Unnecessary or repeated plugging in and unplugging should be avoided or the connector may fail.