background image

ELL10 Linear Stage Evaluation Kit

 

Chapter 8: Thorlabs Worldwide Contacts 

Page 16

 

 

ETN039959-D02 

 

Thorlabs verifies our compliance with the WEEE (Waste Electrical and Electronic Equipment) directive of 

the European Community and the corresponding national laws. Accordingly, all end users in the EC may 

return “end of life” Annex I category electrical and electronic equipment sold after August 13, 2005 to 

Thorlabs, without incurring disposal charges. Eligible units are marked with the crossed out “wheelie bin” 

logo (see right), were sold to and are currently owned by a company or institute within the EC, and are 

not dissembled or contaminated. Contact Thorlabs for more information. Waste treatment is your own 

responsibility. “End of life” units must be returned to Thorlabs or handed to a company specializing in 

waste recovery. Do not dispose of the unit in a litter bin or at a public waste disposal site.

 

 

Annex I 

Chapter 8     Thorlabs Worldwide Contacts

USA, Canada, and South America 

Thorlabs, Inc. 

56 Sparta Avenue 

Newton, NJ 07860 

USA 

Tel: 973-300-3000 

Fax: 973-300-3600 

www.thorlabs.com 

www.thorlabs.us (West Coast) 

Email: sales@thorlabs.com 

Support: [email protected] 

UK and Ireland 

Thorlabs Ltd. 

1 Saint Thomas Place 

Ely

 CB7 4EX 

Great Britain 

Tel: +44 (0)

 

1353-654440 

Fax: +44 (0)

 

1353-654444 

www.thorlabs.com 

Email: [email protected] 

Support: [email protected] 

Europe 

Thorlabs GmbH 

Hans-Böckler-Str. 6 

85221 Dachau 

/ Munich

Germany 

Tel: +49-(0)

 

8131-5956-0 

Fax: +49-(0)

 

8131-5956-99 

www.thorlabs.de 

Email: europe@thorlabs.com

 

Scandinavia 

Thorlabs Sweden AB 

Bergfotsgatan 7 

431 35 Mölndal 

Sweden 

Tel: +46-31-733-30-00 

Fax: +46-31-703-40-45 

www.thorlabs.com 

Email: [email protected]

 

France 

Thorlabs SAS 

109, rue des Côtes 

78600 Maisons-Laffitte 

France 

Tel: +33 (0) 970 444 844 

Fax: +33 (0) 825 744 800 

www.thorlabs.com 

Email: [email protected] 

Brazil

 

Thorlabs Vendas de Fotônicos Ltda. 

Rua Riachuelo, 171 

São Carlos, SP 13560-110 

Brazil 

Tel: +55-16-3413 7062 

Fax: +55-16-3413 7064 

www.thorlabs.com 

Email: [email protected] 

Japan 

Thorlabs Japan, Inc. 

3-6-3, Kitamachi, 

Nerima-ku, Tokyo 179-0081 

Japan 

Tel: +81-3-6915-7701 

Fax: +81-3-6915-7716 

www.thorlabs.co.jp 

Email: [email protected] 

China

 

Thorlabs China 

Room A101, No. 100

, Lane 2891

South Qilianshan Road 

Putuo District 

Shanghai 

China 

Tel: +86 (0) 21-60561122 

Fax: +86 (0)

 

21-32513480 

www.thorlabschina.cn 

Email: [email protected]

Содержание ELL10(K)

Страница 1: ...ELL10 K Linear Translation Stage Operating Manual Original Instructions ...

Страница 2: ......

Страница 3: ...er 7 4 2 2 Software Control 8 4 2 3 Communications Protocol 9 4 2 4 Connecting Multiple Devices 9 4 2 5 Controlling the stage without the handset 9 Frequency Search 11 Periodic Cycling of Devices Over Full Range of Travel 11 Restoring Factory Settings 11 Simultaneous Movement of Devices 11 Chapter 5 Troubleshooting and FAQ 12 Chapter 6 Specifications 13 Chapter 7 Regulatory 15 Declarations of Conf...

Страница 4: ......

Страница 5: ...i drop serial communication protocol and a set of digital IO lines allows the user to control the movement and state manually by switching the lines high 5V or low 0V The stage is designed for closed loop applications requiring linear positioning over a 60 mm 2 36 travel range with 0 5 µm of resolution The module is powered via an external 5V power supply supplied in the kit A hand held controller...

Страница 6: ...t may be impaired In particular excessive moisture may impair operation The equipment is susceptible to damage from electrostatic discharge When handling the device anti static precautions must be taken and suitable discharge appliances must be worn Spillage of fluid such as sample solutions should be avoided If spillage does occur clean up immediately using absorbent tissue Do not allow spilled f...

Страница 7: ... exposed to corrosive agents or excessive moisture heat or dust Do not expose the stage to magnetic fields as this could affect the positioning and homing sensor operation If the unit has been stored at a low temperature or in an environment of high humidity it must be allowed to reach ambient conditions before being powered up The unit is not designed to be used in explosive environments The unit...

Страница 8: ... to the sensor should be below 5mT When handling the stage take care not to touch the wires to the motors Do not bend the wires over the motor spring as this affects the performance of the unit Do not allow the wires to contact other moving parts The recommended mounting orientation is horizontal A base plate is shipped fitted to the stage to allow mounting to a standard 1 or 25 mm pitch optical t...

Страница 9: ...ion Figure 3 Fixing the ELL10 to the work surface 1 Slide the moving world to one end of travel to gain access to the mounting holes as shown above 2 Attach the stage to the work surface by passing appropriate standard fixings not supplied through the exposed hole in the PCB and base plate 3 Slide the moving world to the other end of travel and repeat item 2 ...

Страница 10: ...n 3 2 2 Connect the handset to the stage if required Caution The unit is easily damaged by connections with incorrect polarity Pin 1 of the connector on the PCB is marked with an arrow see Figure 4 and Figure 6 which should be adjacent to the red wire in the connecting cable 3 Connect the stage to a 5V supply and switch ON A 5V PSU is supplied with the ELL10K 4 Connect the unit to your PC if requi...

Страница 11: ...sition The ELL10K Evaluation Kit also contains a hand held controller which features two buttons marked FW and BW that allow control of the stage position The handset also provides for connection to the host PC and to the external 5V power supply The external PSU connector allows the stage to be used in the absence of a PC with control being achieved via the handset buttons LED1 green is lit when ...

Страница 12: ...ler to the stage unit 3 Connect the hand held controller to the 5V Power Supply and switch on 4 Connect the hand held controller to the PC USB port and wait for the drivers to be installed 5 Run the Elliptec software 6 In the top left of the GUI panel displayed select the COM port to which the device is connected and click Connect The software will search the comms bus and enumerate the device 7 C...

Страница 13: ... instructions are contained in the help file supplied with the software Connect the first device to the PC USB port then run the Elliptec software and load the device Change the address of the first device Connect the next device to the first device Change the address of the second device Multiple devices can be controlled individually either via a remote handset connected to each device via the E...

Страница 14: ... IN RX receive 3 3V TTL RS232 4 OUT In Motion open drain active low max 5mA 5 IN JOG Mode active low max 5V 6 IN BW Backward active low max 5V 7 IN FW Forward active low max 5V 8 PWR VCC 5V 10 850mA Connector model number MOLEX 90814 0808 Farnell order code 1518211 Mating connector model number MOLEX 90327 0308 Farnell order code 673160 Figure 5 Connector J1 pin out details ...

Страница 15: ...p of debris on the track and will prevent the motors digging a groove over the most used area of contact Typically a travel cycle should be performed every 10K operations Restoring Factory Settings Factory settings can be restored during the start up calibration test as follows 1 Remove power from the stage 2 Press and hold the BW button do not release until item 6 3 POWER UP 4 WAIT for red led to...

Страница 16: ...on Integrators should search for optimal frequency on every power up sequence commands s1 s2 see ELL protocol document How do I restore the factory default settings Factory settings can be restored at any time see Section 4 5 What is the product lifetime ELL10 product lifetime is restricted by the wearing of moving surfaces and the motor contact as motion is started due to resonance build up and p...

Страница 17: ...Load c 60 to 100 Max Total Load d 200 g Minimum Lifetime e 100 km of travel Electrical Motor Type Elliptec Resonant Piezo DC Voltage Input 4 5 to 5 5V Typical Current Consumption During Movement No Load 0 85 A Typical Standby Current 0 034 A Notes a Performance specifications are given for the case when the linear stage is mounted as recommended in the Section 2 3 b Deviation from the Ideal Path R...

Страница 18: ...Command Format Mnemonic Character 8 Conductor Ribbon Cable Length Supplied 250 mm 8 Conductor Ribbon Cable Length Maximum 3 m General Operating Temperature Range 15 to 40 C 59 to 104 F Dimensions at center travel with bracket fitted 102 3 x 67 0 x 18 4 mm 4 03 x 2 64 x 0 73 Dimensions at end of travel with bracket fitted 114 0 x 67 0 x 18 4 mm 4 49 x 2 64 x 0 73 Dimensions of interface board 66 0 ...

Страница 19: ...against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user wil...

Страница 20: ... www thorlabs us West Coast Email sales thorlabs com Support techsupport thorlabs com UK and Ireland Thorlabs Ltd 1 Saint Thomas Place Ely CB7 4EX Great Britain Tel 44 0 1353 654440 Fax 44 0 1353 654444 www thorlabs com Email sales uk thorlabs com Support techsupport uk thorlabs com Europe Thorlabs GmbH Hans Böckler Str 6 85221 Dachau Munich Germany Tel 49 0 8131 5956 0 Fax 49 0 8131 5956 99 www t...

Страница 21: ......

Страница 22: ...www thorlabs com ...

Отзывы: