9
Installation (Continued)
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON.
1.
The Gas Ovens do not require an electrical connection, as they function totally on the gas
supply only.
2.
It is essential that the gas supply is correct for the appliance to be installed and that
adequate supply pressure and volume are available. The following checks should
therefore be made before installation:-
a. Gas Type required for the appliance is shown in the rating label. Check that this is correct for
the gas supply the appliance is being installed for. The gas conversion procedure is detailed
in this manual.
b. Supply Pressure required for this appliance is shown in the ‘Gas supply requirements’ section
of this manual. Check the gas supply to ensure adequate supply pressure exists.
c. Input Rate of this appliance is stated on the Rating label .The input rate should be checked
against the available gas supply line capacity. Particular note should be taken if the appliance is
being added to an existing installation.
NOTE: It is important that adequately sized piping runs directly to the connection joint on the
appliance with as few tees and elbows as possible to give maximum supply volume.
NOTE: Ensure the regulator is converted to the correct gas type that the appliance will operate on. The
regulator outlet pressure is fixed ex-factory for the gas type .
3.
Correctly locate the appliance into its final operating position and using a spirit level, adjust
the legs so that the unit is level and at the correct height.
4.
Connect the gas supply to the appliance through the regulator. A suitable jointing compound
which resists the breakdown action of propane must be used on every gas line connection,
unless compression fittings are used.
5.
Check all gas connections for leakages.
WARNING:
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.
6.
Check that the gas operating pressure.
7.
Turn off the mains gas supply and bleed the gas out of the appliance gas lines.
8.
Turn on the gas supply and the appliance.
9.
Verify the operating pressure remains correct.
Low Flame Setting
Check the low flame setting by lighting the oven and heating to a set temperature. When the set temperature
has been reached the thermostat will reduce the oven burner flame to its low rate. Check that rapid closing of
the oven door does not extinguish the flame. If necessary, adjustment to the low flame setting is made by
removing the oven knob and turning the bypass adjustment screw (Clockwise to decrease and anti-clockwise
to increase the flame). Care should be taken, as the appliance will become hot during commissioning.
Note: To obtain the above burner pressures adjust the regulator as supplied with the unit. When the correct
operating pressure has been obtained then re-assemble unit.
WARNING: Failure to check and set the oven low flame setting may initiate an un-necessary
service call due to the oven burner "going out".