108
Section 6: Electrical System
Generator
The factory-installed generator will produce 120-volt AC power for use when camping in
areas where shore power is unavailable. 120-volt power from the generator is output to the
AC distribution center by way of a factory-installed automatic transfer switch. In the default
mode, the automatic transfer switch connects the generator to the AC distribution center
when the generator is operating and shore power is disconnected.
50 amp Power Cord
The 50-amp external utility power cord is commonly referred to as the “shore” power cord.
It is designed to mate and properly function with 50-amp “shore” power receptacles avail-
able at most campgrounds.
The shore power cord is designed to continuously carry the 50-amp current flow required to
power each leg of the electrical system. It also creates a critical ground connection between
the vehicle electrical system and the campground shore power receptacle.
Always test the external power source (i.e., the campsite power receptacle or electrical box)
with a ground monitor before connecting your power cord to it. If the ground monitor indi-
cates ‘reverse polarity’ or an ‘open ground’,
DO NOT connect the power cord.
Regularly inspect the shore power cord for cuts, cracks, worn insulation and other damage.
Have the power cord replaced immediately if problems exist.
Calculating 50 amp Electrical Load (if so equipped)
When connecting appliances to the electrical system, 120-volt power usage is limited to 50
amps per electrical system leg for a total of 100 amps. Operating appliances collectively
places an added load on your 120-volt electrical system.
A circuit breaker “trip” may occur if you overload the recreation vehicle and/or campground
electrical system. The amperage rating of individual appliances can be calculated by di-
viding appliance wattage consumed (normally listed on the appliance) by nominal design
voltage (120 for a 120-volt appliance). For example: 1200 watts divided by 120-volts equals
10 amps.
Do not hook up the power cord to any receptacle
until
you have verified
proper polarity and grounding. Polarity indicators can be purchased in
most electrical and hardware stores.
Do not use any cheater plug, adapter or extension cord to reconfigure
incoming AC power or break the continuity of the circuit connected to
the grounding pin.
Do not connect the power cord into an outlet that is not grounded, or
adapt the power cord plug to connect it to a receptacle for which it is not
designed.
Do not remove the grounding pin to connect to a non-grounded recep-
tacle. Removal of the ground pin disables an important safety feature
designed to prevent shock and electrocution hazards.
Do not connect the power cord to an extension cord. Use of an improper
extension cord will cause overheating of the cord as well as potentially
causing premature failure of the AC equipment.
It is the responsibility of the owner of the electrical receptacle to ensure that the
receptacle is properly wired and grounded. Reverse polarity and/or improper
grounding of your recreation vehicle can cause personal injury or death.
Содержание Jayco NORTH POINT 2021
Страница 1: ...Owner s Manual 2021 FIFTHWHEELS 0263154 2021 A subsidiary of Thor Industries Inc...
Страница 2: ......
Страница 10: ...8...
Страница 24: ...22 Section 1 Warranty Service Notes...
Страница 34: ...32 Section 2 Occupant Safety Notes...
Страница 42: ...40 Section 3 Pre Travel Information Notes...
Страница 72: ...70 Section 4 Vehicle Operation Notes...
Страница 122: ...120 Section 7 Fuel Propane System Notes...
Страница 162: ...160 Section 8 Plumbing System Notes...
Страница 166: ...164 Section 9 Heating Cooling Notes...
Страница 178: ...176 Section 10 Appliances Notes...
Страница 184: ...182 Section 11 Electronics Notes...
Страница 204: ...202 Section 14 Travel Camping Storage Checklists Notes...
Страница 209: ...207 Section 15 Additional Information Notes...