H-DVB-S2X-MOD
Thor Fiber 2018 Tel: (800) 521-8467 Email: [email protected] http://www.thorbroadcast.com
than 450Kg/
㎡
)
Environment
Temperature
5~40
℃
(sustainable)
,
0~45
℃
(short time)
installing air-conditioning is recommended
Relative Humidity
20%~80% sustainable 10%~90% short time
Pressure
86~105KPa
Door & Window
Installing rubber strip for sealing door-gaps and dual
level glasses for window
Fire Protection
Fire alarm system and extinguisher
Power
Device power, HVAC and lighting should be independent to
each other. Device power requires AC 110V±10%, 50/60Hz
or AC 220V±10%, 50/60Hz. Please carefully check before
running.
2.2.3 Grounding Requirement
Must be operated and maintained in an area free of dust and debris.
The cover should be securely fastened, do not open the cover of the chassis when the power is on. This
will also void Thor’s manufacturer’s warranty.
After installation, securely stow away all loose cables, external antenna, and others.
Be careful when connecting a power source to the device.
Do not operate in wet or damp areas. Make sure the extension cable is in good condition
Make sure the power switch is off before you start to install the device
It is important to keep this device grounded to ensure all of the modules function correctly. Correctly
grounding the device will also help prevent any electrical interference, lightening. Etc. Also it helps
reject minor interference that may disrupt the devices ability to function smoothly. General rule of
them, make sure the device is grounded when installing anywhere.
Always use copper wire. When applied correctly the ground must be wrapped well to ensure
maximum conduction so it can reduce any high frequencies. The copper ground wire should also be
as short and thick as possible
Installer must make sure that the two ends of the ground are well conducted and have appropriate
anti-rust properties.