Specification
General
Commercial heavy duty hot plate with cast iron trivets and burners, and fitted with full pilot and flame failure
protection.
Pack Contents
The following is included:
Thor Gas Hot Plate
Feet
Instruction Manual
Gas Supply Requirements
2
The burner operating pressure is to be measured at the manifold test point with two burners
operating at full setting. The operating pressure is ex-factory set, through the appliance regulator
and is not to be adjusted.
Minimum input Heat of burner:
21MJ for LPG AND NG
Size of the pan:
The biggest pan for open burner is 280mm.
Natural Gas
Propane
GH107-N
GH107-P
Single burner Heat Input
32.5 MJ
32.5 MJ
Heat Total
130.0 MJ
130.0 MJ
Burner Operating
1.0kPa
2.75kPa
Supply Pressure
1.0kPa
2.75kPa
Gas Connection
¾” BSP
¾” BSP