background image

10 

 

Cleaning and Maintenance 

 

 

 

 

CAUTION: 

 

Always turn off the gas supply before cleaning. 

This appliance is not water proof. 

Do not use water jet spray to clean this appliance. 

 

 

 

GENERAL 

 

Clean the Gas Hot Plate regularly.  A clean Gas Hot Plate looks better, will last longer and will 

perform better. Carbonised grease on the surface or between the trivets, will hinder the transfer of 

heat from the cooking surface to the food.  This will result in loss of cooking efficiency. 

 

 

 

DO NOT use water on the trivets, burners while these items are still hot as warping and cracking may 

occur.  Allow these items to cool down and then remove for cleaning. 

The entire trivets burner can be dismantled for cleaning. 

 

NOTE: 

• DO NOT use abrasive detergents, strong solvents or caustic detergents as they could corrode or 

damage the Gas Hot Plate. 

• In order to prevent the forming of rust on the trivets, and burners, ensure that any detergent or 

cleaning material has been completely removed after each cleaning. 

 

DAILY CLEANING 

 

1. 

The drip tray should be checked and emptied frequently to prevent overflow and spillage. 

Remove the drip tray while still warm so that the grease is in a liquid state.  Empty any grease 

from the trays and wash thoroughly in the same manner as any cooking utensil. 

2. 

Remove the burner, the trivets and thoroughly clean the splash back, interior and exterior 

surfaces of the range with hot water, a detergent solution and a soft scrubbing brush. 

3. 

Dry the Gas Hot Plate thoroughly with a dry cloth and polish with a soft dry cloth. 

 

 

NOTE:  

 

• If the Hot Plate usage is very high, we recommend that the weekly cleaning procedure is carried out 

on a more frequent basis. 

• Ensure that protective gloves are worn during the cleaning process. 
• DO NOT use harsh abrasive detergents, strong solvents or caustic detergents as they will damage 

the grate and burners. 

• Allow these items castings to cool and remove for cleaning. 
• Parts protected by the manufacturer or his agent are not to be adjusted by the installer, unless the 

installer is an authorized service agent. 

 

 

Periodic Maintenance 

 

NOTE:  All maintenance operations should only be carried out by a qualified service person. 

 

To achieve the best results cleaning must be regular and thorough and all controls and mechanical parts 

should be checked and adjusted periodically by a qualified service person.  If any small faults occur, have 

them attended to promptly.  Don't wait until they cause a complete breakdown. 

 

Содержание GE756-N

Страница 1: ...mmable vapors or liquids in the vicinity of this or any other appliances Keep the area free and clear of combustible WARNING Improper installation adjustment alteration service or maintenance can caus...

Страница 2: ...ion Requirements Unpacking Location Clearances Assembly Gas Connection Operation 7 Operation Guide Description of Controls Open Burners Cleaning and Maintenance 10 General After Each Use Daily Cleanin...

Страница 3: ...PERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCA...

Страница 4: ...Input 32 5 MJ 32 5 MJ 32 5 MJ 32 5 MJ Heat Total 65 MJ 195 MJ 65 MJ 195 MJ Burner Operating 1 0kPa 1 0kPa 2 75kPa 2 75kPa Supply Pressure 1 0kPa 1 0kPa 2 75kPa 2 75kPa Gas Connection BSP BSP BSP BSP...

Страница 5: ...3 Dimensions GE756 P GE756 N GE757 P GE757 N...

Страница 6: ...adjusted by an authorized service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from the appliance including all protective plastic...

Страница 7: ...being installed for The gas conversion procedure is detailed in this manual b Supply Pressure required for this appliance is shown in the Gas supply requirements section of this manual Check the gas s...

Страница 8: ...e Operation section of this manual Light the Pilot Burner Light the Main Burner Turning Off the Main Burner Pilot b Ensure that the operator has been instructed in the areas of correct lighting operat...

Страница 9: ...d by the manufacturer should not be adjusted by the user operator 1 The Gas Hot Plates have been designed to provide simplicity of operation and 100 safety protection 2 Improper operation is therefore...

Страница 10: ...zo igniter provided optional 3 Release the gas control knob after approximately 10 20 seconds after lighting the pilot burner 4 The pilot burner should stay alight if not repeat Steps b to c above 5 F...

Страница 11: ...reate air cross currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system Otherwise a su...

Страница 12: ...warm so that the grease is in a liquid state Empty any grease from the trays and wash thoroughly in the same manner as any cooking utensil 2 Remove the burner the trivets and thoroughly clean the spla...

Страница 13: ...he gas control knobs are a push fit onto the gas control valve spindles and can be removed to allow cleaning of the front of the control panel b Baked on deposits or dis colouration may require a good...

Страница 14: ...ly Ensure gas isolation valve is turned on and that bottles are not empty Call the service provider Pilot goes out when gas control knob released Releasing knob before the thermocouple has heated Pilo...

Страница 15: ...ntact your nearest authorized service branch When ordering replacement parts please quote the part number and the description listing below If the part required is not listed below request the part by...

Страница 16: ...14 Explosion Drawing GE756 P GE756 N...

Страница 17: ...L Connector For Manifold GE756 P GE756 N 01 02 1005351 1 11 Regulator GE756 P GE756 N 01 22 1069526 1 12 Flame Device System Rear No include injector GE756 P GE756 N 01 22 1069540 1 ODS Injector 0 20...

Страница 18: ...16 Explosion Drawing GE757 P GE757 N...

Страница 19: ...L Connector For Manifold GE757 P GE757 N 01 02 1005351 1 11 Regulator GE757 P GE757 N 01 22 1069526 1 12 Flame Device System Rear No include injector GE757 P GE757 N 01 22 1069540 3 ODS Injector 0 20...

Страница 20: ...18 Please keep this manual in a safe place for future use 15 Badgally Road Campbelltown NSW 2560 V1 Rev0 05 15...

Отзывы: