3
Specifications
General
Commercial heavy duty oven.
Pack Contents
The following is included:
Thor Gas Oven
2pcs racks
4pcs Feet
Instruction Manual
Gas Supply Requirements
Natural Gas
Propane
GH100-N
GH101-N
GH102-N
GH100-P
GH101-P
GH102-P
Single burner Heat Input
32.5 MJ
32.5 MJ
32.5 MJ
32.5 MJ
32.5 MJ
32.5 MJ
Oven burner
26.5MJ
26.5MJ
26.5MJ
28MJ
32.5 MJ
32.5 MJ
Heat Total
156.5 MJ
221.5 MJ
189MJ
158 MJ
227.5 MJ
195MJ
Burner Operating
1.0 kPa
2.75 kPa
Supply Pressure
1.0 kPa
2.75 kPa
Gas Connection
¾” BSP Male
¾” BSP Male
Natural Gas
Propane
GE542-N
GE543-N
GE544-N
GE542-P
GE543-P
GE545-P
Single burner Heat Input
32.5 MJ
32.5 MJ
32.5 MJ
32.5 MJ
32.5 MJ
32.5 MJ
Oven burner
26.5MJ
26.5MJ
26.5MJ
28MJ
32.5 MJ
32.5 MJ
Heat Total
91.5 MJ
156.5 MJ
124MJ
93 MJ
162.5MJ
130MJ
Burner Operating
1.0 kPa
2.75 kPa
Supply Pressure
1.0 kPa
2.75 kPa
Gas Connection
¾” BSP Male
¾” BSP Male
The burner operating pressure is to be measured at the gas control valve outlet test point with two burner
operating at ‘High’ setting. The operating pressure is ex-factory set, through the appliance regulator and not
to be adjusted, apart from when carrying out gas conversion, if required. (Refer to the ‘Gas Conversion’
section for details).
Minimum input of burner: Open burner:
23MJ for NG
‘U’ burner:
21MJ for NG
Size of the pan:
The smallest pan for open burner is 100mm;
The biggest pan for open burner is 300mm.
The highest temperature of griddle plate is 290
℃(
thermostat valve
)
The highest temperature of griddle plate is 390
℃ (
safety valve
)
.The burner operating pressure is to be
measured at the gas control valve outlet test point with one burner operating at ‘High’ setting. The operating
pressure is ex-factory set, through the appliance regulator and not to be adjusted.