background image

 

 

Introduction 

 

 

We are confident that you will be delighted with your Thor Gas Oven, and it will become a most valued 
appliance in your commercial kitchen. 
To ensure you receive the utmost benefit from your new Gas Oven, there are two important things you 
can do. 

 

Firstly:

 

 

Please read the instruction book carefully and follow the directions given.  The time taken will be well 
spent. 

 

Secondly:

 

 

If you are unsure of any aspect of the installation, instructions or performance of your appliance, 
contact your dealer promptly.  In many cases a phone call could answer your question. 

 

CE Only:

 

 

These instructions are only valid if the country code appears on the appliance.  If the code does not 
appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for 
adapting the appliance to the conditions for use in that country. 

 

 
 
 

WARNING:

 

 

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY 
DAMAGE, INJURY OR DEATH. 

 

READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR 
SERVICING THIS APPLIANCE. 

 

 
 
 

WARNING:

 

 

INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT 
LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER. 

 
 

 

WARNING:

 

 

GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF 
FIRE. 
• 

THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED. 

• 

IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO 

ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED. 

• 

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS 

OR ANY OTHER APPLIANCE. 

• 

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION. 

 

 

 

CAUTION

 

THIS APPLIANCE IS; 

• 

FOR PROFESSIONAL USE AND IS TO BE USED BY QUALIFIED PERSONS ONLY. 

• 

ONLY QUALIFIED SERVICE PERSONS ARE TO CARRY OUT INSTALLATION, SERVICING AND GAS CONVERSION 
OPERATIONS. 

• 

COMPONENTS HAVING ADJUSTMENTS PROTECTED BY THE MANUFACTURER SHOULD NOT BE ADJUSTED BY 
THE USER/OPERATOR. 

• 

DO NOT OPERATE THE APPLIANCE WITHOUT THE LEGS SUPPLIED FITTED. 

Содержание GE542-N

Страница 1: ...ine or other flammable vapors or liquids in the vicinity of this or any other appliances Keep the area free and clear of combustible WARNING Improper installation adjustment alteration service or main...

Страница 2: ...ances Assembly Gas Connection Low Flame Setting Commissioning Operation 10 Operation Guide Description of Controls Lighting the Pilot Burner Lighting the Main Burner Cleaning and Maintenance 13 Routin...

Страница 3: ...READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE PO...

Страница 4: ...J 130MJ Burner Operating 1 0 kPa 2 75 kPa Supply Pressure 1 0 kPa 2 75 kPa Gas Connection BSP Male BSP Male The burner operating pressure is to be measured at the gas control valve outlet test point w...

Страница 5: ...P GH100 N 610 835 680 750 1175 940 TR 0 G24F T GE542 P GE542 N 610 835 610 680 750 510 1175 940 TR 6F GH101 P GH101 N 915 835 680 750 1175 940 TR 4F G12F T GH102 P GH102 N 915 835 305 680 750 510 117...

Страница 6: ...ations Installations must be carried out by qualified persons only Failure to install equipment to the relevant codes and manufacturer s specifications shown in this section will void the warranty Com...

Страница 7: ...ercome a slightly uneven floor 1 Raise unit sufficiently to allow leg pads and legs to be attached For safety shore up and support the unit with an adequate blocking arrangement strong enough to suppo...

Страница 8: ...les are pre drilled and threaded 3 Screw the caster into the holes in the centers of the leg pads Install the casters that have a locking brake under the front of the unit 4 Lower unit gently onto a l...

Страница 9: ...mbustion is supplied from underneath the unit The legs must always be fitted and no obstructions placed on the underside or around the base of the unit as obstructions will cause incorrect operation a...

Страница 10: ...ory for the gas type 3 Correctly locate the appliance into its final operating position and using a spirit level adjust the legs so that the unit is level and at the correct height 4 Connect the gas s...

Страница 11: ...e areas of correct lighting operation and shutdown procedure for the appliance 2 This manual must be kept by the owner for future reference and a record of the Date of Purchase Date of Installation an...

Страница 12: ...Y THE MANUFACTURER SHOULD NOT BE ADJUSTED BY THE USER OPERATOR 1 The Gas Ovens have been designed to provide simplicity of operation and 100 safety protection 2 Improper operation is therefore almost...

Страница 13: ...t burner 4 The pilot burner should stay alight if not repeat Steps b to c above 5 Full Flame can now be achieved by depressing and rotating the gas control knob anti clockwise to the first stop HIGH f...

Страница 14: ...ich create air cross currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system Otherwise...

Страница 15: ...face with SCOTCH BERITE sourcing pads or STAINLESS sourcing pads DO NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust and further spoil the appearance of the finish NEVER USE...

Страница 16: ...LATE Remove enameled top plate and spiders clean with a solution of hot water and strong soap or detergent The area around the charge port where the splash tube is attached to the burner must be free...

Страница 17: ...ing or the flames leaving the ports Lack of primary air causes soft or yellow tipped flame OVEN LOW FLAME LEVEL SETTING When the oven reaches the temperature at which the dial is set the oven thermost...

Страница 18: ...list for injector orifice size for specific gas type 9 Replace the ODS injector Follow the ODS injector removal procedure See parts list for injector orifice size for specific gas type OPENING OF THE...

Страница 19: ...agent will require the following information TROUBLESHOOTING RANGE TOP BURNERS Consult the following table and the flowchart that begins on the following page Problem Look for All burners and pilots...

Страница 20: ...ner Shut off the main gas supply Install a pressure tap in the main gas line before the range pressure regulator and install a manometer Turn on the main gas supply Re light all pilots NOTE Griddle To...

Страница 21: ...hot tops Install the thermostat bulbs into griddle tops Be sure the capillary tubes are away from burners flames and excessive heat Propane burners may have a small amount of yellow tipping This is no...

Страница 22: ...n for 30 seconds The pilot should light and remain lit after the button is released If the pilot doesn t remain lit wait 5 minutes and retry If the pilot doesn t remain lit remove the thermocouple fro...

Страница 23: ...OFF position This is the bypass setting Check that there is a 6mm flame at each port If the flame is not correct remove the knobs and bezel There is a slotted screw below the stem on the thermostat va...

Страница 24: ...H to increase and L to decrease the temperature NOTE Only turn this screw by small increments While holding the knobs at 150 setting push the screw in and turn it in the direction indicated to change...

Страница 25: ...eplacement parts please quote the part number and the description listing below If the part required is not listed below request the part by description and quote model number and serial number which...

Страница 26: ...Explosion drawing 25...

Страница 27: ...bly Oven GH100 P GH100 N 06 05 1472080 1 GH101 P GH101 N 06 05 1472080 1 GH102 P GH102 N 06 05 1472080 1 GE542 P GE542 N 06 05 1472080 1 GE543 P GE543 N 06 05 1472080 1 GE544 P GE544 N 06 05 1472080 1...

Страница 28: ...01 24 1070914 GH102 P GH102 N 01 24 1070915 1 GE542 P GE542 N 01 24 1070988 1 GE543 P GE543 N 01 24 1070991 1 GE544 P GE544 N 01 24 1070992 1 14 Pilot Pipe Assembly Right GH102 P GH102 N 06 05 147197...

Страница 29: ...2 P GH102 N GE543 P GE543 N 01 22 1069540 1 2 3 1 ODS Injector 0 2 01 20 1068546 ODS Injector 0 4 01 20 1068547 26 Main Pipe Back Assembly GH100 P GH100 N 01 24 1070901 1 01 24 1070901 GH101 P GH101 N...

Страница 30: ...4 1 GE542 P GE542 N 01 22 1069534 1 GE543 P GE543 N 01 22 1069534 1 GE544 P GE544 N 01 22 1069534 1 35 Door Hinge GH100 P GH100 N 06 05 1471140 2 GH101 P GH101 N 06 05 1471140 2 GH102 P GH102 N 06 05...

Страница 31: ...V1 Rev4 05 15...

Страница 32: ...Please keep this manual in a safe place for future use 15 Badgally Road Campbelltown NSW 2560...

Отзывы: