background image

INSTALLATION GUIDE

IMPORTANT–PLEASE READ AND 
FOLLOW

•  Before beginning, read these instructions thoroughly and 

carefully.

•  Because the kit includes metal parts, caution should be 

used in handling and installation to avoid the possibility 
of injury.

•  Do not remove permanently affixed labels, warnings or 

plates from the product as this may void the warranty. 

•  Observe all local and national codes, requirements and 

ordinances. 

•  Installers should leave these instructions with the con-

sumer who should retain them for the local inspector’s use 
and for future reference.

•  For SAFETY CONSIDERATIONS do not install drawer in 

any combustible cabinetry, which is not in accord with the 
stated clearances and dimensions on page 4, See figure 1.

ELECTRICAL GROUNDING INSTRUCTIONS 

This oven must be electrically grounded in accordance 

with local codes or, in the absence of local codes,  

with the National Electrical Code, 

ANSI/NFPA 70 – latest edition.

DO NOT USE AN EXTENSION CORD WITH THIS 

APPLIANCE. SUCH USE MAY RESULT IN FIRE, 

ELECTRICAL SHOCK OR OTHER PERSONAL INJURY.

IMPORTANT SAFETY 

INSTRUCTIONS

•  WARNING: If the information in this manual is not followed 

exactly, a fire or electrical shock may result that could cause 
property damage, personal injury or death.

•  WARNING: To reduce the risk of tipping, the Drawer Micro-

wave must be secured by a properly installed Anti-Tip block.

•  This appliance must be electrically grounded in accordance 

with local codes.

•  Make sure the wall coverings and the cabinets around the 

Drawer Microwave can withstand the heat generated by 
the appliance.

•  WARNING: Never leave children alone or unattended in the 

area where a appliance is in use. Never leave the drawer 
open when the microwave is unattended.

•  WARNING: Stepping, leaning or sitting on the drawer may 

result in serious injuries and can also cause damage to 
the appliance.

•  Do not use the Drawer Microwave as a storage space. This 

creates a potentially hazardous situation.

•  Check that the time-of-day is in the display. If not, touch 

Stop/Clear to prevent unintended use.

2

E

Содержание TMD2401

Страница 1: ...MODEL TMD2401 INSTALLATION GUIDE 24 DRAWER MICROWAVE...

Страница 2: ...st edition DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE SUCH USE MAY RESULT IN FIRE ELECTRICAL SHOCK OR OTHER PERSONAL INJURY IMPORTANT SAFETY INSTRUCTIONS WARNING If the information in this manua...

Страница 3: ...m clearance Locate electrical outlet in the shaded area in the upper left hand corner of the cutout See figure 4 Contact surface must be solid and level Pay special at tention to the floor on which th...

Страница 4: ...2 A 21 5 8 549 28 mm B 4 11 16 119 06 mm C 1 3 4 44 45 mm D 21 7 8 555 60 mm E 23 7 8 606 43 mm F 15 7 8 403 22 mm G 14 19 32 370 69 mm H 1 9 64 29 mm door thickness I 15 381 mm auto drawer opening J...

Страница 5: ...e electrical wiring or plumbing 6 152 4 mm 3 1 2 89 mm Anti Tip block FIGURE 3 ELECTRICAL OUTLET The electrical requirements are a 120 volt 60 Hz AC only 15 amp or more protected electrical supply It...

Страница 6: ...drill the cabinet using a 1 16 bit See figure 5A 5 Secure the drawer with the 4 screws supplied See figure 5B MODEL AND SERIAL NUMBER LOCATION The nameplate includes model number and serial number Op...

Страница 7: ...RIQUE OU AUTRE BLESSURE INSTRUCTIONS DE S RET IMPORTANTES ADVERTISSEMENT Si l on ne suit pas de pr s les indica tions dans ce manuel il y a un risque d incendie ou de d charge lectrique qui pourrait p...

Страница 8: ...e ob serv es Ces dimensions offrent un d gagement minimal Rep rer la prise lectrique dans l aire ombr e dans le coin gauche sup rieur de la d coupe Voir Sch ma 4 La surface de contact doit tre solide...

Страница 9: ...4 11 16 po 119 06 mm C 1 3 4 po 44 45 mm D 21 7 8 po 555 60 mm E 23 7 8 po 606 43 mm F 15 7 8 po 403 22 mm G 14 19 32 po 370 69 mm H paisseur de la porte 1 9 64 po 29 mm I Ouverture tiroir 15 po 381 m...

Страница 10: ...Faire attention que les vis ne p n trent pas dans le c blage lectrique ou la plomberie Bloc antibasculement 6 po 153 mm 3 1 2 89 mm SCH MA 3 PRISE DE COURANT Le courant alimentation est 120 volts 60...

Страница 11: ...6 po Voir Sch ma 5A 5 Fixer le tiroir avec les 4 vis fournies Voir Sch ma 5B EMPLACEMENT DES NUM ROS DE MOD LE ET DE S RIE La plaque d identification comprend les num ros de s rie et de mod le Ouvrir...

Страница 12: ...TINSKB317MRR0 Apr 5 2021...

Отзывы: