2
9
Connect range to gas supply
1.
Install male
1
/
2
” or
3
/
4
” (
3
/
4
” refers to 48-inch gas range) flare union adapter to the NPT
internal thread of the manual shut-off valve, taking care to secure the shut-off valve to keep it
from turning.
2.
The gas supply pressure for checking the regulator setting is 6 in.w.c. (Nature Gas) and 11
inch.w.c. (LP gas) connect flexible gas line connector to the regulator on the range. Position
range to permit connection at the shut-off valve.
3.
When all connections have been made, make sure all range controls are in the positionand
turn on main gas supply valve.
4.
Leak testing of the appliance shall be conducted according to the manufacturer’sinstructions.
Use some soap water (50% water and 50% soap) or a leak detector at all joints and
connections to check for leaks in the system. Do not use a flame to check for gasleaks.
5.
The appliance must be isolated from the building’s gas supply piping system by closing its
individual manual shut-off valve during any pressure testing of the gas supply piping system at
test pressure equal to or less than
1
/
2
psig(3.5kPa).
After installation:
1. Check ignition of cooktop burners.
2. Check ignition of oven burner.
3. Visually check tubular burner (oven burner) re-ignition to be sure both rows of burner portsare
relighting each time.
4. Check for gas leaks at all gas connections (using a gas detector, never aflame).
5. Check oven bake and convection bakefunction.
Содержание LRG2401U
Страница 1: ...USE AND CARE MANUAL COOK LIKE A GOD LRG MODELS LRG4807U LRG3601U LRG3001U LRG2401U...
Страница 2: ...GAS RANGES USE AND CARE MANUAL LRG MODELS LRG4807U ULP LRG3601U ULP LRG3001U ULP LRG2401U ULP...
Страница 16: ...Dimension and Clearance 14 BTU Design...
Страница 17: ...Dimension and Clearance 15 LRG3001U LRG3601U LRG4801U And LRG4807U LRG2401U...
Страница 18: ...Dimension and Clearance 16 LRG3001U LRG2401U...
Страница 20: ...Dimension and Clearance 18...
Страница 21: ...19 Dimension and Clearance 30 Gas Range Clearance...
Страница 22: ...20 Dimension and Clearance 36 Gas Range Clearance...
Страница 23: ...Dimension and Clearance 21 48 Gas Range Clearance...
Страница 26: ...Dimension and Clearance Installation for LRG 24 inches Gas Range 24...
Страница 27: ...25 Dimension and Clearance Installation for LRG 30 and 36 inches Gas Range...
Страница 28: ...26 Dimension and Clearance Back Layout for LRG 48 inches Gas Range...
Страница 29: ...Dimension and Clearance Gas Line Connection 27...